14 research outputs found

    Evaluation of in-situ shrinkage and expansion properties of polymer composite materials for adhesive anchor systems by a novel approach based on digital image correlation

    Get PDF
    The curing reaction of thermosetting resins is associated with chemical shrinkage which is overlapped with thermal expansion as a result of the exothermal enthalpy. Final material properties of the polymer are determined by this critical process. For adhesive anchor systems the overall shrinkage behavior of the material is very important for the ultimate bond behavior between adhesive and the borehole wall. An approach for the insitu measurement of 3-dimensional shrinkage and thermal expansion with digital image correlation (DIC) is presented, overcoming the common limitation of DIC to solids. Two polymer-based anchor systems (filled epoxy, vinylester) were investigated and models were developed, showing good agreement with experimental results. Additionally, measurements with differential scanning calorimetry (DSC) provided supporting information about the curing reaction. The vinylester system showed higher shrinkage but much faster reaction compared to the investigated epoxy

    In situ SAXS study on cationic and non-ionic surfactant liquid crystals using synchrotron radiation

    Get PDF
    In situ synchrotron small-angle X-ray scattering was used to investigate various surfactant/water systems with hexagonal and lamellar structures regarding their structural behaviour upon heating and cooling. Measurements of the non-ionic surfactant Triton X-45 (polyethylene glycol 4-tert-octylphenyl ether) at different surfactant concentrations show an alignment of the lamellar liquid-crystalline structure close to the wall of the glass capillaries and also a decrease in d-spacing following subsequent heating/cooling cycles. Additionally, samples were subjected to a weak magnetic field (0.3-0.7 T) during heating and cooling, but no influence of the magnetic field was observed

    Characterization of moisture uptake and diffusion mechanisms in particle-filled composites

    No full text
    This study investigates moisture uptake and diffusion mechanisms in thermoset particle-filled composites for anchor applications. Two epoxy-based with low inorganic filler content and one vinyl ester-based with high inorganic filler content were studied. Material characterization revealed particle size distribution, particle density, the occurrence of pores, and filler composition. Moisture diffusion was monitored at different temperatures, different relative humidities, and in water immersion for up to 540 days. Based on these results a sorption isotherm, temperature dependencies, and diffusion paths could be determined. A phenomenological hybridisotherm, consisting of a combination of Henry's linear isotherm and Type III isotherm, was applied to describe the effect of different fillers on equilibrium moisture uptake. Fickian diffusion was observed for all composites with temperature-dependent Arrhenius relation. These observations allowed us to suggest three diffusion paths: through the polymer matrix, on the matrix-filler interfaces, and through matrix and fillers simultaneously

    Metal–Insulator Transition of Ultrathin Sputtered Metals on Phenolic Resin Thin Films: Growth Morphology and Relations to Surface Free Energy and Reactivity

    No full text
    Nanostructured metal assemblies on thin and ultrathin polymeric films enable state of the art technologies and have further potential in diverse fields. Rational design of the structure–function relationship is of critical importance but aggravated by the scarcity of systematic studies. Here, we studied the influence of the interplay between metal and polymer surface free energy and reactivity on the evolution of electric conductivity and the resulting morphologies. In situ resistance measurements during sputter deposition of Ag, Au, Cu and Ni films on ultrathin reticulated polymer films collectively reveal metal–insulator transitions characteristic for Volmer–Weber growth. The different onsets of percolation correlate with interfacial energy and energy of adhesion weakly but as expected from ordinary wetting theory. A more pronounced trend of lower percolation thickness for more reactive metals falls in line with reported correlations. Ex situ grazing incidence small angle X-ray scattering experiments were performed at various thicknesses to gain an insight into cluster and film morphology evolution. A novel approach to interpret the scattering data is used where simulated pair distance distributions of arbitrary shapes and arrangements can be fitted to experiments. Detailed approximations of cluster structures could be inferred and are discussed in view of the established parameters describing film growth behavior

    Vacuum Casting and Mechanical Characterization of Nanocomposites from Epoxy and Oxidized Multi-Walled Carbon Nanotubes

    Get PDF
    Sample preparation is an important step when testing the mechanical properties of materials. Especially, when carbon nanotubes (CNT) are added to epoxy resin, the increase in viscosity complicates the casting of testing specimens. We present a vacuum casting approach for different geometries in order to produce specimens from functional nanocomposites that consist of epoxy matrix and oxidized multi-walled carbon nanotubes (MWCNTs). The nanocomposites were characterized with various mechanical tests that showed improved fracture toughness, bending and tensile properties performance by addition of oxidized MWCNTs. Strengthening mechanisms were analyzed by SEM images of fracture surfaces and in-situ imaging by digital image correlation (DIC)

    Solvent-Free Ultrasonic Dispersion of Nanofillers in Epoxy Matrix

    No full text
    Dispersion of carbon nanotubes and carbon nanofibers is a crucial processing step in the production of polymer-based nanocomposites and poses a great challenge due to the tendency of nanofillers to agglomerate. One of the most effective methods for dispersion is the use of a three-roll mill, which is a well-established method and results in agglomerates below 5 µm. Nevertheless, this process is time-consuming and thus a limiting factor for industrial applications. Our aim was to establish an easy and efficient ultrasonic dispersion process, characterize the dispersion parameters, and compare both methods, ultrasonication and the three-roll mill. We applied rheological tests and analyzed the agglomerate sizes by an image fit of the microscopy images. All these analyses combined deliver a valuable set of information about the dispersion’s quality and, therefore, allows the improvement and further adaptation of the dispersion process

    Impact of selected solvent systems on the pore and solid structure of cellulose aerogels

    Get PDF
    International audienceThe impact of selected cellulose solvent systems based on the principal constituents tetrabutyl-ammonium fluoride (TBAF), 1-ethyl-3-methyl-1H-imidazolium-acetate, N-methylmorpholine-N-oxide, or calcium thiocyanate octahydrate (CTO) on the properties of cellulose II aerogels prepared from these solvent systems has been investigated as a means towards tailoring cellulose aerogel properties with respect to specific applications. Cotton linters were used as representative plant cellulose. Cellulose was coagulated from solutions with comparable cellulose content, and dried with supercritical carbon dioxide after solvent exchange. The resulting bulk aerogels were comprehensively morphologically and mechanically tested to relate structure and mechanical properties. Different solvent systems caused considerable differences in the properties of the bulk samples, such as internal surface area (nitrogen sorption), morphology , porosity (He pycnometry, thermoporosimetry), and mechanical stability (compression testing). The results of SAXS, WAXS, and solid-state 13 C NMR spectroscopy suggest that this is due to different mechanisms of cellulose self-assembling on the supramolecular and nanostructural level, respectively, as reflected by the broad ranges of cellulose crys-tallinity, fibril diameter, fractal dimension and skeletal density. Both solid state NMR and WAXS experiments confirmed the sole existence of the cellulose II allomorph for all aerogels, with crystallinity reaching a maximum of 46–50 % for CTO-derived aerogels. Generally, higher fibril diameter, degree of crys-tallinity, hence increased skeletal density were associated with good preservation of shape and dimension throughout conversion of lyogels to aerogels, and enhanced mechanical stability, but somewhat reduced specific surface area. Amorphous, yet highly rigid aerogels derived from TBAF/DMSO mixtures deviated from this trend, most likely due to their particular homogeneous and nanostructured morphology

    Carbon Microparticles from Organosolv Lignin as Filler for Conducting Poly(Lactic Acid)

    No full text
    Carbon microparticles were produced from organosolv lignin at 2000 °C under argon atmosphere following oxidative thermostabilisation at 250 °C. Scanning electron microscopy, X-ray diffraction, small-angle X-ray scattering, and electro-conductivity measurements revealed that the obtained particles were electrically conductive and were composed of large graphitic domains. Poly(lactic acid) filled with various amounts of lignin-derived microparticles showed higher tensile stiffness increasing with particle load, whereas strength and extensibility decreased. Electric conductivity was measured at filler loads equal to and greater than 25% w/w

    µXRF Elemental Mapping of Bioresorbable Magnesium-Based Implants in Bone

    No full text
    This study investigated the distribution of the elemental constituents of Mg-based implants at various stages of the degradation process in surrounding bone tissue, with a focus on magnesium (Mg), as the main component of the alloy, and yttrium (Y), due to its potential adverse health effects. The measurements were performed on the implant-bearing thin sections of rat bone in a time series of implant degradation between one and 18 months. Micro X-ray fluorescence analysis (μXRF) with a special spectrometer meeting the requirements for the measurements of low-Z elements was used. It was found that the migration and accumulation behaviour of implant degradation products is element-specific. A sharp decrease in Mg was observed in the immediate vicinity of the interface and no specific accumulation or aggregation of Mg in the adjacent bone tissue was detected. By contrast, Y was found to migrate further into the bone over time and to remain in the tissue even after the complete degradation of the implant. Although the nature of Y accumulations must still be clarified, its potential health impact should be considered.ISSN:1996-194
    corecore