184 research outputs found

    Poor accuracy of freehand cup positioning during total hip arthroplasty

    Get PDF
    Several studies have demonstrated a correlation between the acetabular cup position and the risk of dislocation, wear and range of motion after total hip arthroplasty. The present study was designed to evaluate the accuracy of the surgeon’s estimated position of the cup after freehand placement in total hip replacement. Peroperative estimated abduction and anteversion of 200 acetabular components (placed by three orthopaedic surgeons and nine residents) were compared with measured outcomes (according to Pradhan) on postoperative radiographs. Cups were placed in 49.7° (SD 6.7) of abduction and 16.0° (SD 8.1) of anteversion. Estimation of placement was 46.3° (SD 4.3) of abduction and 14.6° (SD 5.9) of anteversion. Of more interest is the fact that for the orthopaedic surgeons the mean inaccuracy of estimation was 4.1° (SD 3.9) for abduction and 5.2° (SD 4.5) for anteversion and for their residents this was respectively, 6.3° (SD 4.6) and 5.7° (SD 5.0). Significant differences were found between orthopaedic surgeons and residents for inaccuracy of estimation for abduction, not for anteversion. Body mass index, sex, (un)cemented fixation and surgical approach (anterolateral or posterolateral) were not significant factors. Based upon the inaccuracy of estimation, the group’s chance on future cup placement within Lewinnek’s safe zone (5–25° anteversion and 30–50° abduction) is 82.7 and 85.2% for anteversion and abduction separately. When both parameters are combined, the chance of accurate placement is only 70.5%. The chance of placement of the acetabular component within 5° of an intended position, for both abduction and anteversion is 21.5% this percentage decreases to just 2.9% when the tolerated error is 1°. There is a tendency to underestimate both abduction and anteversion. Orthopaedic surgeons are superior to their residents in estimating abduction of the acetabular component. The results of this study indicate that freehand placement of the acetabular component is not a reliable method

    Are component positioning and prosthesis size associated with hip resurfacing failure?

    Get PDF
    BACKGROUND: Recent studies suggest that there is a learning curve for metal-on-metal hip resurfacing. The purpose of this study was to assess whether implant positioning changed with surgeon experience and whether positioning and component sizing were associated with implant longevity. METHODS: We evaluated the first 361 consecutive hip resurfacings performed by a single surgeon, which had a mean follow-up of 59 months (range, 28 to 87 months). Pre and post-operative radiographs were assessed to determine the inclination of the acetabular component, as well as the sagittal and coronal femoral stem-neck angles. Changes in the precision of component placement were determined by assessing changes in the standard deviation of each measurement using variance ratio and linear regression analysis. Additionally, the cup and stem-shaft angles as well as component sizes were compared between the 31 hips that failed over the follow-up period and the surviving components to assess for any differences that might have been associated with an increased risk for failure. RESULTS: Surgeon experience was correlated with improved precision of the antero-posterior and lateral positioning of the femoral component. However, femoral and acetabular radiographic implant positioning angles were not different between the surviving hips and failures. The failures had smaller mean femoral component diameters as compared to the non-failure group (44 versus 47 millimeters). CONCLUSIONS: These results suggest that there may be differences in implant positioning in early versus late learning curve procedures, but that in the absence of recognized risk factors such as intra-operative notching of the femoral neck and cup inclination in excess of 50 degrees, component positioning does not appear to be associated with failure. Nevertheless, surgeons should exercise caution in operating patients with small femoral necks, especially when they are early in the learning curve

    Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty

    Get PDF
    Background The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. Methods Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. Results The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. Conclusions SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT- imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses

    Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Impingement can be a serious complication after total hip arthroplasty (THA), and is one of the major causes of postoperative pain, dislocation, aseptic loosening, and implant breakage. Minimally invasive THA and computer-navigated surgery were introduced several years ago. We have developed a novel, computer-assisted operation method for THA following the concept of "femur first"/"combined anteversion", which incorporates various aspects of performing a functional optimization of the cup position, and comprehensively addresses range of motion (ROM) as well as cup containment and alignment parameters. Hence, the purpose of this study is to assess whether the artificial joint's ROM can be improved by this computer-assisted operation method. Second, the clinical and radiological outcome will be evaluated.</p> <p>Methods/Design</p> <p>A registered patient- and observer-blinded randomized controlled trial will be conducted. Patients between the ages of 50 and 75 admitted for primary unilateral THA will be included. Patients will be randomly allocated to either receive minimally invasive computer-navigated "femur first" THA or the conventional minimally invasive THA procedure. Self-reported functional status and health-related quality of life (questionnaires) will be assessed both preoperatively and postoperatively. Perioperative complications will be registered. Radiographic evaluation will take place up to 6 weeks postoperatively with a computed tomography (CT) scan. Component position will be evaluated by an independent external institute on a 3D reconstruction of the femur/pelvis using image-processing software. Postoperative ROM will be calculated by an algorithm which automatically determines bony and prosthetic impingements.</p> <p>Discussion</p> <p>In the past, computer navigation has improved the accuracy of component positioning. So far, there are only few objective data quantifying the risks and benefits of computer navigated THA. Therefore, this study has been designed to compare minimally invasive computer-navigated "femur first" THA with a conventional technique for minimally invasive THA. The results of this trial will be presented as soon as they become available.</p> <p>Trial registration number</p> <p>DRKS00000739</p

    Influence of surgical approach on component positioning in primary total hip arthroplasty

    Get PDF
    Background: Minimal invasive surgery (MIS) has gained growing popularity in total hip arthroplasty (THA) but concerns exist regarding component malpositioning. The aim of the present study was to evaluate femoral and acetabular component positioning in primary cementless THA comparing a lateral to a MIS anterolateral approach. Methods: We evaluated 6 week postoperative radiographs of 52 hips with a minimal invasive anterolateral approach compared to 54 hips with a standard lateral approach. All hips had received the same type of implant for primary cementless unilateral THA and had a healthy hip contralaterally. Results: Hip offset was equally restored comparing both approaches. No influence of the approach was observed with regard to reconstruction of acetabular offset, femoral offset, vertical placement of the center of rotation, stem alignment and leg length discrepancy. However, with the MIS approach, a significantly higher percentage of cups (38.5 %) was malpositioned compared to the standard approach (16.7 %) (p = 0.022). Conclusions: The MIS anterolateral approach allows for comparable reconstruction of stem position, offset and center of rotation compared to the lateral approach. However, surgeons must be aware of a higher risk of cup malpositioning for inclination and anteversion using the MIS anterolateral approach

    Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature

    Get PDF
    ABSTRACT: BACKGROUND: Both minimally invasive surgery (MIS) and computer-assisted surgery (CAS) for total hip arthroplasty (THA) have gained popularity in recent years. We conducted a qualitative and systematic review to assess the effectiveness of MIS, CAS and computer-assisted MIS for THA. METHODS: An extensive computerised literature search of PubMed, Medline, Embase and OVIDSP was conducted. Both randomised clinical trials and controlled clinical trials on the effectiveness of MIS, CAS and computer-assisted MIS for THA were included. Methodological quality was independently assessed by two reviewers. Effect estimates were calculated and a best-evidence synthesis was performed. RESULTS: Four high-quality and 14 medium-quality studies with MIS THA as study contrast, and three high-quality and four medium-quality studies with CAS THA as study contrast were included. No studies with computer-assisted MIS for THA as study contrast were identified. Strong evidence was found for a decrease in operative time and intraoperative blood loss for MIS THA, with no difference in complication rates and risk for acetabular outliers. Strong evidence exists that there is no difference in physical functioning, measured either by questionnaires or by gait analysis. Moderate evidence was found for a shorter length of hospital stay after MIS THA. Conflicting evidence was found for a positive effect of MIS THA on pain in the early postoperative period, but that effect diminished after three months postoperatively. Strong evidence was found for an increase in operative time for CAS THA, and limited evidence was found for a decrease in intraoperative blood loss. Furthermore, strong evidence was found for no difference in complication rates, as well as for a significantly lower risk for acetabular outliers. CONCLUSIONS: The results indicate that MIS THA is a safe surgical procedure, without increases in operative time, blood loss, operative complication rates and component malposition rates. However, the beneficial effect of MIS THA on functional recovery has to be proven. The results also indicate that CAS THA, though resulting in an increase in operative time, may have a positive effect on operative blood loss and operative complication rates. More importantly, the use of CAS results in better positioning of acetabular component of the prosthesis

    Diagnostic Value of Lumbar Facet Joint Injection: A Prospective Triple Cross-Over Study

    Get PDF
    The diagnosis “lumbar facet syndrome” is common and often indicates severe lumbar spine surgery procedures. It is doubtful whether a painful facet joint (FJ) can be identified by a single FJ block. The aim of this study was to clarify the validity of a single and placebo controlled bilateral FJ blocks using local anesthetics. A prospective single blinded triple cross-over study was performed. 60 patients (31 f, 29 m, mean age 53.2 yrs (22–73)) with chronic low back pain (mean pain persistance 31 months, 6 months of conservative treatment without success) admitted to a local orthopaedic department for surgical or conservative therapy of chronic LBP, were included in the study. Effect on pain reduction (10 point rating scale) was measured. The 60 subjects were divided into six groups with three defined sequences of fluoroscopically guided bilateral monosegmental lumbar FJ test injections in “oblique needle” technique: verum-(local anaesthetic-), placebo-(sodium chloride-) and sham-injection. Carry-over and periodic effects were evaluated and a descriptive and statistical analysis regarding the effectiveness, difference and equality of the FJ injections and the different responses was performed. The results show a high rate of non-response, which documents the lack of reliable and valid predictors for a positive response towards FJ blocks. There was a high rate of placebo reactions noted, including subjects who previously or later reacted positively to verum injections. Equivalence was shown among verum vs. placebo and partly vs. sham also. With regard to test validity criteria, a single intraarticular FJ block with local anesthetics is not useful to detect the pain-responsible FJ and therefore is no valid and reliable diagostic tool to specify indication of lumbar spine surgery. Comparative FJ blocks with local anesthetics and placebo-controls have to be interpretated carefully also, because they solely give no proper diagnosis on FJ being main pain generator
    • …
    corecore