96 research outputs found
Retirement, health and relationships of the older population in England: The 2004 English Longitudinal Study Of Ageing (Wave 2)
Physical Activity, Sedentary Time and Physical Capability in Early Old Age: British Birth Cohort Study
Purpose
To investigate the associations of time spent sedentary, in moderate-to-vigorous-intensity physical activity (MVPA) and physical activity energy expenditure (PAEE) with physical capability measures at age 60-64 years.
Methods
Time spent sedentary and in MVPA and, PAEE were assessed using individually calibrated combined heart rate and movement sensing among 1727 participants from the MRC National Survey of Health and Development in England, Scotland and Wales as part of a detailed clinical assessment undertaken in 2006-2010. Multivariable linear regression models were used to examine the cross-sectional associations between standardised measures of each of these behavioural variables with grip strength, chair rise and timed up-&-go (TUG) speed and standing balance time.
Results
Greater time spent in MVPA was associated with higher levels of physical capability; adjusted mean differences in each capability measure per 1standard deviation increase in MVPA time were: grip strength (0.477 kg, 95% confidence interval (CI): 0.015 to 0.939), chair rise speed (0.429 stands/min, 95% CI: 0.093 to 0.764), standing balance time (0.028 s, 95% CI: 0.003 to 0.053) and TUG speed (0.019 m/s, 95% CI: 0.011 to 0.026). In contrast, time spent sedentary was associated with lower grip strength (-0.540 kg, 95% CI: -1.013 to -0.066) and TUG speed (-0.011 m/s, 95% CI: -0.019 to -0.004). Associations for PAEE were similar to those for MVPA.
Conclusion
Higher levels of MVPA and overall physical activity (PAEE) are associated with greater levels of physical capability whereas time spent sedentary is associated with lower levels of capability. Future intervention studies in older adults should focus on both the promotion of physical activity and reduction in time spent sedentary
Immunoglobulin G; structure and functional implications of different subclass modifications in initiation and resolution of allergy.
IgE and not IgG is usually associated with allergy. IgE lodged on mast cells in skin or gut and basophils in the blood allows for the prolonged duration of allergy through the persistent expression of high affinity IgE receptors. However, many allergic reactions are not dependent on IgE and are generated in the absence of allergen specific and even total IgE. Instead, IgG plasma cells are involved in induction of, and for much of the pathogenesis of, allergic diseases. The pattern of IgG producing plasma cells in atopic children and the tendency for direct or further class switching to IgE are the principle factors responsible for long-lasting sensitization of mast cells in allergic children. Indirect class switching from IgG producing plasma cells has been shown to be the predominant pathway for production of IgE while a Th2 microenvironment, genetic predisposition, and the concentration and nature of allergens together act on IgG plasma cells in the atopic tendency to undergo further immunoglobulin gene recombination. The seminal involvement of IgG in allergy is further indicated by the principal role of IgG4 in the natural resolution of allergy and as the favourable immunological response to immunotherapy. This paper will look at allergy through the role of different antibodies than IgE and give current knowledge of the nature and role of IgG antibodies in the start, maintenance and resolution of allergy
Comparison of devices used to measure blood pressure, grip strength and lung function: A randomised cross-over study
BACKGROUND: Blood pressure, grip strength and lung function are frequently assessed in longitudinal population studies, but the measurement devices used differ between studies and within studies over time. We aimed to compare measurements ascertained from different commonly used devices. METHODS: We used a randomised cross-over study. Participants were 118 men and women aged 45–74 years whose blood pressure, grip strength and lung function were assessed using two sphygmomanometers (Omron 705-CP and Omron HEM-907), four handheld dynamometers (Jamar Hydraulic, Jamar Plus+ Digital, Nottingham Electronic and Smedley) and two spirometers (Micro Medical Plus turbine and ndd Easy on-PC ultrasonic flow-sensor) with multiple measurements taken on each device. Mean differences between pairs of devices were estimated along with limits of agreement from Bland-Altman plots. Sensitivity analyses were carried out using alternative exclusion criteria and summary measures, and using multilevel models to estimate mean differences. RESULTS: The mean difference between sphygmomanometers was 3.9mmHg for systolic blood pressure (95% Confidence Interval (CI):2.5,5.2) and 1.4mmHg for diastolic blood pressure (95% CI:0.3,2.4), with the Omron HEM-907 measuring higher. For maximum grip strength, the mean difference when either one of the electronic dynamometers was compared with either the hydraulic or spring-gauge device was 4-5kg, with the electronic devices measuring higher. The differences were small when comparing the two electronic devices (difference = 0.3kg, 95% CI:-0.9,1.4), and when comparing the hydraulic and spring-gauge devices (difference = 0.2kg, 95% CI:-0.8,1.3). In all cases limits of agreement were wide. The mean difference in FEV1 between spirometers was close to zero (95% CI:-0.03,0.03), limits of agreement were reasonably narrow, but a difference of 0.47l was observed for FVC (95% CI:0.53,0.42), with the ndd Easy on-PC measuring higher. CONCLUSION: Our study highlights potentially important differences in measurement of key functions when different devices are used. These differences need to be considered when interpreting results from modelling intra-individual changes in function and when carrying out cross-study comparisons, and sensitivity analyses using correction factors may be helpful
Sensitivity to food additives, vaso-active amines and salicylates: a review of the evidence
The Cloning and Expression of Human Monoclonal Antibodies: Implications for Allergen Immunotherapy
Are Milk Polyamines Preventive Agents against Food Allergy?
Insufficient polyamine intake could play a role in the induction of sensitization to dietary allergens. This proposal is based essentially on investigations made in sucking rats and in children. In sucking rats it has been established that oral administration of spermine can induce all the modifications occurring in the digestive tract at weaning. In the intestine events occur in two phases. The early event consists of desquamation of the epithelium resulting from an activation of apoptosis. The late event appears to involve an hormonal cascade in which adrenocorticotropic hormone, cytokines, bombesin and corticosterone are included. Observations in human subjects show that: (1) the spermine and spermidine concentrations are generally lower in infant formulas than in human breast milk. Mothers seem consistently to have relatively high or relatively low concentrations of spermine and spermidine in their milk. These individual variations may be due to diet, lifestyle or genetic background; (2) the probability of developing allergy can reach 80 % if the mean spermine concentration in the milk is lower than 2 nmol/ml milk. It is approximately 0 % if the mean spermine concentration is higher than 13 nmol/ml milk; (3) preliminary results show that the intestinal permeability to macromolecules differs in premature babies when they are fed on breast milk compared with infant formulas (J Senterre, J Rigo, G Forget, G Dandrifosse and N Romain, unpublished results). This difference does not seem to be present when powdered milk is supplemented with polyamines at the concentration found in breast milk; (4) spermine increases proliferation and differentiation of lymphocytes isolated from the tonsils of children
- …
