20 research outputs found

    HyperCP: A high-rate spectrometer for the study of charged hyperon and kaon decays

    Full text link
    The HyperCP experiment (Fermilab E871) was designed to search for rare phenomena in the decays of charged strange particles, in particular CP violation in Ξ\Xi and Λ\Lambda hyperon decays with a sensitivity of 10−410^{-4}. Intense charged secondary beams were produced by 800 GeV/c protons and momentum-selected by a magnetic channel. Decay products were detected in a large-acceptance, high-rate magnetic spectrometer using multiwire proportional chambers, trigger hodoscopes, a hadronic calorimeter, and a muon-detection system. Nearly identical acceptances and efficiencies for hyperons and antihyperons decaying within an evacuated volume were achieved by reversing the polarities of the channel and spectrometer magnets. A high-rate data-acquisition system enabled 231 billion events to be recorded in twelve months of data-taking.Comment: 107 pages, 45 Postscript figures, 14 tables, Elsevier LaTeX, submitted to Nucl. Instrum. Meth.

    Search for the Lepton-Number-Violating Decay Ξ−→pΌ−Ό−\Xi^- \to p \mu^- \mu^-

    Full text link
    A sensitive search for the lepton-number-violating decay Ξ−→pΌ−Ό−\Xi^-\to p \mu^-\mu^- has been performed using a sample of ∌109\sim10^9 Ξ−\Xi^- hyperons produced in 800 GeV/cc pp-Cu collisions. We obtain B(Ξ−→pΌ−Ό−)<4.0×10−8\mathcal{B}(\Xi^-\to p \mu^-\mu^-)< 4.0\times 10^{-8} at 90% confidence, improving on the best previous limit by four orders of magnitude.Comment: 9 pages, 5 figures, to be published in Phys. Rev. Let

    Evidence for the Decay Sigma+ -> p mu+ mu-

    Full text link
    We report the first evidence for the decay Sigma+ -> p mu+ mu- from data taken by the HyperCP experiment(E871) at Fermilab. Based on three observed events, the branching ratio is B(Sigma+ -> p,mu+,mu-) = [8.6 +6.6,-5.4(stat) +/-5.5(syst)] x 10**-8. The narrow range of dimuon masses may indicate that the decay proceeds via a neutral intermediate state, Sigma+ -> p P0, P0 -> mu+ mu-, with a P0 mass of 214.3 +/- 0.5 MeV/c**2 and branching ratio B(Sigma+ -> p P0; P0 -> mu+ mu-) = [3.1 +2.4,-1.(stat) +/-1.5(syst)] x 10**-8.Comment: As published in PR

    Measurement of the Alpha Asymmetry Parameter for the Omega- to Lambda K- Decay

    Full text link
    We have measured the alpha parameter of the Omega- to Lambda K- decay using data collected with the HyperCP spectrometer during the 1997 fixed-target run at Fermilab. Analyzing a sample of 0.96 million Omega- to Lambda K^-, Lambda to p pi- decays, we obtain alpha_Omega*alpha_Lambda = [1.33+/-0.33(stat)+/-0.52(syst)] x 10^{-2}. With the accepted value of alpha_Lambda, alpha_Omega is found to be [2.07+/-0.51(stat)+/-0.81(syst)] x 10^{-2}.Comment: 5 pages, 4 figures, to be appeared as a Rapid Communication in Phys. Rev.

    Measurement of αΩ in Ω− → ΛΚ− Decays

    Full text link
    The HyperCP experiment (E871) at Fermilab has collected the largest sample of hyperon decays in the world. With a data set of over a million Ω− → ΛΚ− decays we have measured the product of αΩαΛ from which we have extracted αΩ. This preliminary result indicates that αΩ is small, but non‐zero. Prospects for a test of CP symmetry by comparing the α parameters in Ω− and Ω̄+ decays will be discussed. © 2003 American Institute of PhysicsPeer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87682/2/251_1.pd

    CP Violation in Hyperon and Charged Kaon Decays

    Full text link
    The primary purpose of the HyperCP experiment at Fermilab is to test CP in hyperon decays by comparing the decay distributions for Ξ− (“cascade”) decays in the decay sequence: Ξ− → π− + Λ0, Λ0 → π− + p, with those for the antiparticle Ξ̄+. In addition, we can test CP in charged kaon decays by comparing the slopes of the Dalitz plot for Κ+ and Κ− decays. We are also looking at rare decay modes of charged kaons and hyperons, particularly those involving muons. In two runs in 1997 and 1999, we collected approx. 500 millon charged kaon decays, 2.5 billion Ξ− and Ξ̄+ decays, and 19 million Ω− and Ω̄+ decays. This is the largest sample of fully reconstructed particle decays ever collected. © 2002 American Institute of PhysicsPeer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87464/2/298_1.pd

    High Statistics Search for the Theta+(1.54) Pentaquark State

    Full text link
    We have searched for Theta+(1.54) -> K0,p decays using data from the 1999 run of the HyperCP experiment at Fermilab. We see no evidence for a narrow peak in the K0,p mass distribution near 1.54 GeV/c among 106,000 K0,p candidates, and obtain an upper limit for the fraction of Theta+(1.54) to K0,p candidates of <0.3% at 90% confidence.Comment: 4 pages, 4 figure

    Search for CP Violation in Charged-Xi and Lambda Hyperon Decays

    Full text link
    We have compared the proton and antiproton angular distributions in 117 million Xi-minus -> Lambda + pi-minus -> proton + pi-minus + pi-minus and 41 million anti-Xi-minus -> anti-Lamba + pi-plus -> antiproton + pi-plus + pi-plus decays using a subset of the data from the HyperCP experiment (E871) at Fermilab. We find no evidence of CP violation, with the direct-CP-violating parameter AΞΛ=αΞαΛ−αˉΞαˉΛαΞαΛ+αˉΞαˉΛ=[0.0+/−5.1(stat)+/−4.4(syst)]×10−4A_{\Xi\Lambda} = \frac{\alpha_{\Xi}\alpha_{\Lambda} - \bar{\alpha}_{\Xi}\bar{\alpha}_{\Lambda}}{\alpha_{\Xi}\alpha_{\Lambda} + \bar{\alpha}_{\Xi}\bar{\alpha}_{\Lambda}} = [0.0+/-5.1(stat)+/-4.4(syst)]{\times}10^{-4}.Comment: 4 pages, 4 figures, to be published in Phys. Rev. Let

    CP violation in strange baryon decays: A report from Fermilab experiment 871

    Full text link
    Fermilab experiment 871, HyperCP, is a search for direct CP violation in Ξ and Λ hyperon decays. A non-zero value in the asymmetry parameter A, defined in terms of the decay parameter products αΞαΛαΞαΛ and ,αΞ̄αΛ̄, would be unambiguous evidence for direct CP violation. The first data-taking run finished at the end of 1997 and accumulated over one billion Ξ−Ξ− and +Ξ̄+ decays. A sensitivity in A of ≈ 10−4≈10−4 is expected. A review of CP violation in hyperon decays is given, the HyperCP detector is described, and the status of the data analysis is discussed. © 1999 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87472/2/107_1.pd
    corecore