7 research outputs found

    Different osteosyntheses for Colles' fracture: A mechanical study in 42 cadaver bones

    Get PDF
    Background and purpose In recent years several different plate designs for internal fixation of fractures of the distal radius have been developed. However, few biomechanical studies have been performed to compare these new implants. The purpose of this study was to compare the mechanical properties of 5 different commercially available plates (3 volar and 2 dorsal) with standard K-wire fixation using a distal radial cadaver model

    Osteoporosis as a Risk Factor for Distal Radial Fractures. A Case-Control Study

    Get PDF
    Background: Distal radial fractures occur earlier in life than hip and spinal fractures and may be the first sign of osteoporosis. The aims of this case-control study were to compare the prevalence of osteopenia and osteoporosis between female and male patients with low-energy distal radial fractures and matched controls and to investigate whether observed differences in bone mineral density between patients and controls could be explained by potential confounders. Methods: Six hundred and sixty-four female and eighty-five male patients who sustained a distal radial fracture, and 554 female and fifty-four male controls, were included in the study. All distal radial fractures were radiographically confirmed. Bone mineral density was assessed with use of dual x-ray absorptiometry at the femoral neck, total hip (femoral neck, trochanter, and intertrochanteric area), and lumbar spine (L2-L4). A self-administered questionnaire provided information on health and lifestyle factors. Results: The prevalence of osteoporosis was 34% in female patients and 10% in female controls. The corresponding values were 17% in male patients and 13% in male controls. In the age group of fifty to fifty-nine years, 18% of female patients and 5% of female controls had osteoporosis. In the age group of sixty to sixty-nine years, the corresponding values were 25% and 7%, respectively. In adjusted conditional logistic regression analyses, osteopenia and osteoporosis were significantly associated with distal radial fractures in women. Osteoporosis was significantly associated with distal radial fractures in men. Conclusions: The prevalence of osteoporosis in patients with distal radial fractures is high compared with that in control subjects, and osteoporosis is a risk factor for distal radial fractures in both women and men. Thus, patients of both sexes with an age of fifty years or older who have a distal radial fracture should be evaluated with bone densitometry for the possible treatment of osteoporosis

    Long-term survival of 2997 finger metacarpophalanageal joint arthroplasties from the Norwegian Arthroplasty Register

    No full text
    We present the long-time survival of 2997 primary metacarpophalangeal (MCP) joint implants from the Norwegian Arthroplasty Register from 1994 to 2019. Six different implants were compared in terms of survival and risk of revision. The majority of implants were inserted in patients diagnosed with inflammatory diseases and in women. The overall survival was found to be 94%, 89%, 85% and 84% after 5, 10, 15 and 20 years. The most prevalent reason for revision was a fractured prosthetic component, and the second was pain. Implants inserted in the right hand and in younger patients had a higher risk for revision. Sex, type of implant, finger treated, one- or two-component prosthesis, and inflammatory or non-inflammatory conditions did not influence the survival. The frequency of MCP joint implantations decreased during the observation period. Our data show satisfactory long-term survival of the MCP implants, with no difference found between implant types or concepts.publishedVersio

    Reconfigurable electrostatically doped 2.5-gate planar field-effect transistors for dopant-free CMOS

    Get PDF
    In this paper, we demonstrate by extending TCAD simulations based on experimental data of fabricated electrostatically doped, reconfigurable planar double-gate field-effect transistors, the improved characteristics of a triple gate device design. The technological cornerstones for this general-purpose FET comprise mid-gap Schottky S/D junctions on a silicon-on-insulator substrate. The transistor type, i.e. n-type or p-type, is interchangeable during operation by applying a control-gate voltage which significantly increases the flexibility and versatility in the design of integrated circuits
    corecore