2,181 research outputs found

    The chaotic behavior of the black hole system GRS 1915+105

    Get PDF
    A modified non-linear time series analysis technique, which computes the correlation dimension D2D_2, is used to analyze the X-ray light curves of the black hole system GRS 1915+105 in all twelve temporal classes. For four of these temporal classes D2D_2 saturates to 45\approx 4-5 which indicates that the underlying dynamical mechanism is a low dimensional chaotic system. Of the other eight classes, three show stochastic behavior while five show deviation from randomness. The light curves for four classes which depict chaotic behavior have the smallest ratio of the expected Poisson noise to the variability (<0.05 < 0.05) while those for the three classes which depict stochastic behavior is the highest (>0.2 > 0.2). This suggests that the temporal behavior of the black hole system is governed by a low dimensional chaotic system, whose nature is detectable only when the Poisson fluctuations are much smaller than the variability.Comment: Accepted for publication in Astrophysical Journa

    UBVRI photopolarimetry of the long period eclipsing AM Herculis binary V1309

    Get PDF
    We report simultaneous UBVRI photo-polarimetric observations of the long period (7.98 h) AM Her binary V1309 Ori. The length and shape of the eclipse ingress and egress varies from night to night. We suggest this is due to the variation in the brightness of the accretion stream. By comparing the phases of circular polarization zero-crossovers with previous observations, we confirm that V1309 Ori is well synchronized, and find an upper limit of 0.002 percent for the difference between the spin and orbital periods. We model the polarimetry data using a model consisting of two cyclotron emission regions at almost diametrically opposite locations, and centered at colatitude 35 (deg) and 145 (deg) on the surface of the white dwarf. We also present archive X-ray observations which show that the negatively polarised accretion region is X-ray bright.Comment: 11 pages, 12 figures (2 colour), Fig1 and Fig 4 are in lower resolution than in original paper, accepted for publication in Monthly Notices of the Royal Astronomical Societ

    Genetically-predicted life-long lowering of low-density lipoprotein cholesterol is associated with decreased frailty: A Mendelian randomization study in UK biobank

    Get PDF
    BACKGROUND: High circulating low-density lipoprotein cholesterol (LDL-C) is a major risk factor for atherosclerosis and age-associated cardiovascular events. Long-term dyslipidaemia could contribute to the development of frailty in older individuals through its role in determining cardiovascular health and potentially other physiological pathways. METHODS: We conducted Mendelian randomization (MR) analyses using genetic variants to estimate the effects of long-term LDL-C modification on frailty in UK Biobank (n = 378,161). Frailty was derived from health questionnaire and interview responses at baseline when participants were aged 40 to 69 years, and calculated using an accumulation-of-deficits approach, i.e. the frailty index (FI). Several aggregated instrumental variables (IVs) using 50 and 274 genetic variants were constructed from independent single-nucleotide polymorphisms (SNPs) to instrument circulating LDL-C concentrations. Specific sets of variants in or near genes that encode six lipid-lowering drug targets (HMGCR, PCSK9, NPC1L1, APOB, APOC3, and LDLR) were used to index effects of exposure to related drug classes on frailty. SNP-LDL-C effects were available from previously published studies. SNP-FI effects were obtained using adjusted linear regression models. Two-sample MR analyses were performed with the IVs as instruments using inverse-variance weighted, MR-Egger, weighted median, and weighted mode methods. To address the stability of the findings, MR analyses were also performed using i) a modified FI excluding the cardiometabolic deficit items and ii) data from comparatively older individuals (aged ≥60 years) only. Several sensitivity analyses were also conducted. FINDINGS: On average 0.14% to 0.23% and 0.16% to 0.31% decrements in frailty were observed per standard deviation reduction in LDL-C exposure, instrumented by the general IVs consisting of 50 and 274 variants, respectively. Consistent, though less precise, associations were observed in the HMGCR-, APOC3-, NPC1L1-, and LDLR-specific IV analyses. In contrast, results for PCSK9 were in the same direction but more modest, and null for APOB. All sensitivity analyses produced similar findings. INTERPRETATION: A genetically-predicted life-long lowering of LDL-C is associated with decreased frailty in midlife and older age, representing supportive evidence for LDL-C's role in multiple health- and age-related pathways. The use of lipid-lowering therapeutics with varying mechanisms of action may differ by the extent to which they provide overall health benefits

    In vitro dissolution methods for hydrophilic and hydrophobic porous silicon microparticles

    Get PDF
    Porous silicon (PSi) is an innovative inorganic material that has been recently developed for various drug delivery systems. For example, hydrophilic and hydrophobic PSi microparticles have been utilized to improve the dissolution rate of poorly soluble drugs and to sustain peptide delivery. Previously, the well-plate method has been demonstrated to be a suitable in vitro dissolution method for hydrophilic PSi particles but it was not applicable to poorly wetting hydrophobic thermally hydrocarbonized PSi (THCPSi) particles. In this work, three different in vitro dissolution techniques, namely centrifuge, USP Apparatus 1 (basket) and well-plate methods were compared by using hydrophilic thermally carbonized PSi (TCPSi) microparticles loaded with poorly soluble ibuprofen or freely soluble antipyrine. All the methods showed a fast and complete or nearly complete release of both model compounds from the TCPSi microparticles indicating that all methods described in vitro dissolution equally. Based on these results, the centrifuge method was chosen to study the release of a peptide (ghrelin antagonist) from the THCPSi microparticles since it requires small sample amounts and achieves good particle suspendability. Sustained peptide release from the THCPSi microparticles was observed, which is in agreement with an earlier in vivo study. In conclusion, the centrifuge method was demonstrated to be a suitable tool for the evaluation of drug release from hydrophobic THCPSi particles, and the sustained peptide release from THCPSi microparticles was detected

    Theoretical study of kinks on screw dislocation in silicon

    Full text link
    Theoretical calculations of the structure, formation and migration of kinks on a non-dissociated screw dislocation in silicon have been carried out using density functional theory calculations as well as calculations based on interatomic potential functions. The results show that the structure of a single kink is characterized by a narrow core and highly stretched bonds between some of the atoms. The formation energy of a single kink ranges from 0.9 to 1.36 eV, and is of the same order as that for kinks on partial dislocations. However, the kinks migrate almost freely along the line of an undissociated dislocation unlike what is found for partial dislocations. The effect of stress has also been investigated in order to compare with previous silicon deformation experiments which have been carried out at low temperature and high stress. The energy barrier associated with the formation of a stable kink pair becomes as low as 0.65 eV for an applied stress on the order of 1 GPa, indicating that displacements of screw dislocations likely occur via thermally activated formation of kink pairs at room temperature

    The influence of electronic reminders on recording diagnoses in a primary health care emergency department : a register-based study in a Finnish town

    Get PDF
    Objective This study examines whether implementation of electronic reminders is associated with a change in the amount and content of diagnostic data recorded in primary health care emergency departments (ED). Design A register-based 12-year follow-up study with a before-and-after design. Setting This study was performed in a primary health care ED in Finland. An electronic reminder was installed in the health record system to remind physicians to include the diagnosis code of the visit to the health record. Subjects and main outcome measures The report generator of the electronic health record-system provided monthly figures for the number of different recorded diagnoses by using the International Classification of Diagnoses (ICD-10th edition) and the total number of ED physician visits, thus allowing the calculation of the recording rate of diagnoses on a monthly basis and the comparison of diagnoses before and after implementing electronic reminders. Results The most commonly recorded diagnoses in the ED were acute upper respiratory infections of various and unspecified sites (5.8%), abdominal and pelvic pain (4.8%), suppurative and unspecified otitis media (4.5%) and dorsalgia (4.0%). The diagnosis recording rate in the ED doubled from 41.2 to 86.3% (p < 0.001) after the application of electronic reminders. The intervention especially enhanced the recording rate of symptomatic diagnoses (ICD-10 group-R) and alcohol abuse-related diagnoses (ICD-10 code F10). Mental and behavioural disorders (group F) and injuries (groups S-Y) were also better recorded after this intervention. Conclusion Electronic reminders may alter the documentation habits of physicians and recording of clinical data, such as diagnoses, in the EDs. This may be of use when planning resource managing in EDs and planning their actions.Peer reviewe

    Solar-insolation-induced changes in the coma morphology of comet 67P/Churyumov-Gerasimenko. Optical monitoring with the Nordic Optical Telescope

    Get PDF
    Context. 67P/Churyumov-Gerasimenko (67P/C-G) is a short-period Jupiter family comet with an orbital period of 6.55 years. Being the target comet of ESA’s Rosetta mission, 67P/C-G has become one of the most intensively studied minor bodies of the Solar System. The Rosetta Orbiter and the Philae Lander have brought us unique information about the structure and activity of the comet nucleus, as well as its activity along the orbit, composition of gas, and dust particles emitted into the coma. However, as Rosetta stayed in very close proximity to the cometary nucleus (less than 500 km with a few short excursions reaching up to 1500 km), it could not see the global picture of a coma at the scales reachable by telescopic observations (103 - 105 km). Aims. In this work we aim to connect in-situ observations made by Rosetta with the morphological evolution of the coma structures monitored by the ground-based observations. In particular, we concentrate on causal relationships between the coma morphology and evolution observed with the Nordic Optical Telescope (NOT) in the Canary Islands, and the seasonal changes of the insolation and the activity of the comet observed by the Rosetta instruments. Methods. Comet 67P/C-G was monitored with the NOT in imaging mode in two colors. Imaging optical observations were performed roughly on a weekly basis, which provides good coverage of short- and long-term variability. With the three dimensional modeling of the coma produced by active regions on the Southern Hemisphere, we aim to qualify the observed morphology by connecting it to the activity observed by Rosetta. Results. During our monitoring program, we detected major changes in the coma morphology of comet 67P/C-G. These were longterm and long-lasting changes. They do not represent any sudden outburst or short transient event, but are connected to seasonal changes of the surface insolation and the emergence of new active regions on the irregular shaped comet nucleus. We have also found significant deviations in morphological changes from the prediction models based on previous apparitions of 67P/C-G, like the time delay of the morphology changes and the reduced activity in the Northern Hemisphere. According to our modeling of coma structures and geometry of observations, the changes are clearly connected with the activity in the Southern Hemisphere observed by the Rosetta spacecraft

    Marked deterioration in the quality of life of patients with idiopathic pulmonary fibrosis during the last two years of life

    Get PDF
    BackgroundIdiopathic pulmonary fibrosis (IPF) is a chronic disease with a high symptom burden and poor survival that influences patients' health-related quality of life (HRQOL). We aimed to evaluate IPF patients' symptoms and HRQOL in a well-documented clinical cohort during their last two years of life.MethodsIn April 2015, we sent the Modified Medical Research Council Dyspnea Scale (MMRC), the modified Edmonton Symptom Assessment Scale (ESAS) and a self-rating HRQOL questionnaire (RAND-36) to 300 IPF patients, of which 247 (82%) responded. Thereafter, follow-up questionnaires were sent every six months for two years.ResultsNinety-two patients died by August 2017. Among these patients, HRQOL was found to be considerably low already two years before death. The most prominent declines in HRQOL occurred in physical function, vitality, emotional role and social functioning (pPeer reviewe
    corecore