42 research outputs found

    Biomechanics of Circumferential Cervical Fixation Using Posterior Facet Cages: A Cadaveric Study.

    Get PDF
    OBJECTIVE: Anterior cervical discectomy and fusion (ACDF) is a common procedure for the treatment of cervical disease. Circumferential procedures are options for multilevel pathology. Potential complications of multilevel anterior procedures are dysphagia and pseudarthrosis, whereas potential complications of posterior surgery include development of cervical kyphosis and postoperative chronic neck pain. The addition of posterior cervical cages (PCCs) to multilevel ACDF is a minimally invasive option to perform circumferential fusion. This study evaluated the biomechanical performance of 3-level circumferential fusion with PCCs as supplemental fixation to anteriorly placed allografts, with and without anterior plate fixation. METHODS: Nondestructive flexibility tests (1.5 Nm) performed on 6 cervical C2-7 cadaveric specimens intact and after discectomy (C3-6) in 3 instrumented conditions: allograft with anterior plate (G+P), PCC with allograft and plate (PCC+G+P), and PCC with allograft alone (PCC+G). Range of motion (ROM) data were analyzed using 1-way repeated-measures analysis of variance. RESULTS: All instrumented conditions resulted in significantly reduced ROM at the 3 instrumented levels (C3-6) compared to intact spinal segments in flexion, extension, lateral bending, and axial rotation (p \u3c 0.001). No significant difference in ROM was found between G+P and PCC+G+P conditions or between G+P and PCC+G conditions, indicating similar stability between these conditions in all directions of motion. CONCLUSION: All instrumented conditions resulted in considerable reduction in ROM. The added reduction in ROM through the addition of PCCs did not reach statistical significance. Circumferential fusion with anterior allograft, without plate and with PCCs, has comparable stability to ACDF with allograft and plate

    Oligosaccharyltransferase Inhibition Induces Senescence in RTK-Driven Tumor Cells

    Get PDF
    Asparagine (N)-linked glycosylation is a protein modification critical for glycoprotein folding, stability, and cellular localization. To identify small molecules that inhibit new targets in this biosynthetic pathway, we initiated a cell-based high throughput screen and lead compound optimization campaign that delivered a cell permeable inhibitor (NGI-1). NGI-1 targets the oligosaccharyltransferase (OST), a hetero-oligomeric enzyme that exists in multiple isoforms and transfers oligosaccharides to recipient proteins. In non-small cell lung cancer cells NGI-1 blocks cell surface localization and signaling of the EGFR glycoprotein, but selectively arrests proliferation in only those cell lines that are dependent on EGFR (or FGFR) for survival. In these cell lines OST inhibition causes cell cycle arrest accompanied by induction of p21, autofluorescence, and changes in cell morphology; all hallmarks of senescence. These results identify OST inhibition as a potential therapeutic approach for treating receptor tyrosine kinase-dependent tumors and provides a chemical probe for reversibly regulating N-linked glycosylation in mammalian cells

    Mapping the medical outcomes study HIV health survey (MOS-HIV) to the EuroQoL 5 Dimension (EQ-5D-3L) utility index

    Get PDF
    10.1186/s12955-019-1135-8Health and Quality of Life Outcomes1718

    A Novel C2 Screw Trajectory: Preliminary Anatomic Feasibility And Biomechanical Comparison

    No full text
    Background: Pedicle screw and translaminar screw fixation in C2 may not be applicable in many patients with anatomic abnormalities or narrow laminar thickness and spinous process height. The aim of this study was to assess morphometric and mechanical feasibilities of a novel alternative screw trajectory that pierces the bifid base of C2. Methods: Anatomic measurements that determined the feasibility of spinous process bifid base (SPB) screw fixation were assessed in 14 cadaveric C2 vertebrae. Pullout tests to assess ultimate fixation strength for 3 screw trajectories (transpedicular, translaminar, and SPB) were performed in cadaveric vertebrae for comparison. Results: Anatomic measurements included mean spinous process height (10.4 ± 4.2 mm) and mean bilateral bifid base length (10.1 ± 2.2 mm) and thickness (left, 4.4 ± 1.0 mm; right, 4.3 ± 0.9 mm). In 64% (9/14) of specimens, bifid base length was ≥9 mm. Mean pullout strength for transpedicle, translaminar, and SPB screws in 9 viable specimens was 648 ± 305 N, 628 ± 417 N, and 755 ± 279 N. Conclusions: SPB screw fixation may be viable anatomically and mechanically for C2 fixation. Feasibility of SPB screw fixation is determined by length, thickness, and mutual angle of the bilateral bifid bases. Patients with thin (\u3c4 mm) and short (\u3c9 mm) bifid bases are not likely to be suitable candidates. SPB screw fixation shows potential as an alternative approach or a salvage technique for patients with high-riding vertebral arteries or severely thin C2 lamina and warrants further investigation

    Variations among human lumbar spine segments and their relationships to in vitro biomechanics: A retrospective analysis of 281 motion segments from 85 cadaveric spines

    No full text
    © International Society for the Advancement of Spine Surgery Background: Biomechanical properties of intact spinal motion segments are used to establish baseline values during in vitro studies evaluating spinal surgical techniques and implants. These properties are also used to validate computational models (ie, patient-specific finite element models) of human lumbar spine segments. Our laboratory has performed a large number of in vitro mechanical studies of lumbar spinal segments, using a consistent methodology. This provides extensive biomechanical data for a large number of intact motion segments, along with donor demographic variables, bone mineral density (BMD) measurements, and geometric properties. The objective of this study was to analyze how donor demographics, BMD, and geometric properties of cadaveric lumbar spine segments affect motion segment flexibility, including the range of motion (ROM), lax zone (LZ), and stiff zone (SZ), to help improve our understanding of spinal biomechanics. Methods: A retrospective study examined the relationships between the biomechanical properties of 281 lumbar motion segments from 85 human cadaveric spines, donor demographic variables (age, sex, weight, height, and body mass index), and specimen measurements (vertebral body height, intervertebral disc height, and BMD). Results: Statistical correlation and regression analyses showed that the flexibility of a lumbar motion segment is affected by lumbar level, donor age, sex, and weight as well as the intervertebral disc height, vertebral body height, and bone quality. Increased disc height was associated with decreased ROM (axial rotation), decreased LZ (flexion-extension and axial rotation), and increased SZ (flexion-extension and lateral bending) in the male group, but increased ROM (lateral bending) in the female group. Increased vertebral body height correlated with increased LZ (lateral bending) in the female group. Increased BMD correlated with decreased ROM overall. Conclusions: Biomechanical measurements from flexibility testing of cadaveric lumbar spine segments are significantly correlated with donor demographics and specimen measurements. Many of these correlations are sex-dependent

    Biomechanics of Circumferential Cervical Fixation Using Posterior Facet Cages: A Cadaveric Study

    No full text
    OBJECTIVE: Anterior cervical discectomy and fusion (ACDF) is a common procedure for the treatment of cervical disease. Circumferential procedures are options for multilevel pathology. Potential complications of multilevel anterior procedures are dysphagia and pseudarthrosis, whereas potential complications of posterior surgery include development of cervical kyphosis and postoperative chronic neck pain. The addition of posterior cervical cages (PCCs) to multilevel ACDF is a minimally invasive option to perform circumferential fusion. This study evaluated the biomechanical performance of 3-level circumferential fusion with PCCs as supplemental fixation to anteriorly placed allografts, with and without anterior plate fixation. METHODS: Nondestructive flexibility tests (1.5 Nm) performed on 6 cervical C2-7 cadaveric specimens intact and after discectomy (C3-6) in 3 instrumented conditions: allograft with anterior plate (G+P), PCC with allograft and plate (PCC+G+P), and PCC with allograft alone (PCC+G). Range of motion (ROM) data were analyzed using 1-way repeated-measures analysis of variance. RESULTS: All instrumented conditions resulted in significantly reduced ROM at the 3 instrumented levels (C3-6) compared to intact spinal segments in flexion, extension, lateral bending, and axial rotation (p \u3c 0.001). No significant difference in ROM was found between G+P and PCC+G+P conditions or between G+P and PCC+G conditions, indicating similar stability between these conditions in all directions of motion. CONCLUSION: All instrumented conditions resulted in considerable reduction in ROM. The added reduction in ROM through the addition of PCCs did not reach statistical significance. Circumferential fusion with anterior allograft, without plate and with PCCs, has comparable stability to ACDF with allograft and plate

    In Vitro Biomechanical Evaluation Of A Novel Minimally Invasive Sacroiliac Joint Fixation Device

    No full text
    Background: Sacroiliac (SI) joint pathology may result in low-back pain, which causes substantial disability. Treatment failure with operative management of SI pain may be related to incomplete fusion of the joint and to fixation failure. The objective of this study was to evaluate the initial biomechanical stability of SI joint fixation with a novel implantable device in an in vitro human cadaveric model. Methods: The right and left sides of 3 cadaveric L4-pelvis specimens were tested (1) intact, (2) destabilized, and (3) instrumented with an implantable SI joint fixation device using a simulated single-stance load condition. Right-leg and left-leg stance data were grouped together for a sample size of 6, and angular range of motion (ROM) was determined during application of flexion-extension, lateral bending, and axial rotation bending moments to a limit of 7.5 Nm. Results: Following intact testing, destabilization by severing the posterior SI joint capsule and ligaments and the pubic symphysis reliably produced a significantly destabilized joint with the mean angular ROM more than doubling in flexion-extension and lateral bending and more than tripling in axial rotation (P .003) compared to the intact condition. Instrumentation with the SI screw fixation device significantly reduced mean joint ROM compared to the destabilized condition in all 3 anatomic planes tested (P, .001). When compared to the intact condition, the SI-instrumented condition significantly reduced lateral bending (P ¼ .01) and had a similar ROM in flexion-extension (P ¼ .14) and axial rotation (P ¼ .85). Conclusions: Instrumentation with the SI screw fixation device significantly reduced mean joint ROM compared to the destabilized condition, with similar ROM in flexion-extension and axial rotation, and it significantly reduced ROM in lateral bending compared to that for the intact joint. The ROM values observed with the instrumented condition were comparable to levels of mobility considered favorable for spinal fusion

    Biomechanical implications of unilateral facetectomy, unilateral facetectomy plus partial contralateral facetectomy, and complete bilateral facetectomy in minimally invasive transforaminal interbody fusion.

    No full text
    OBJECTIVE: Minimally invasive transforaminal interbody fusion techniques vary among surgeons. One decision point is whether to perform a unilateral facetectomy (UF), a unilateral facetectomy plus partial contralateral facetectomy (UF/PF), or a complete bilateral facetectomy (CBF). The authors therefore compared the biomechanical benefits of all 3 types of facetectomies to determine which approach produces improved biomechanical outcomes. METHODS: Seven human cadaveric specimens (L3-S1) were potted and prepped for UF, with full facet removal, hemilaminectomy, discectomy, and pedicle screw placement. After distraction, a fixed interbody spacer was placed, and compression was performed. A final fixation configuration was performed by locking the rods across the screws posteriorly with bilateral compression. Final lordosis angle and change and foraminal height were measured, and standard nondestructive flexibility tests were performed to assess intervertebral range of motion (ROM) and compressive stiffness. The same procedure was followed for UF/PF and CBF in all 7 specimens. RESULTS: All 3 conditions demonstrated similar ROM and compressive stiffness. No statistically significant differences occurred with distraction, but CBF demonstrated significantly greater change than UF in mean foraminal height after bilateral posterior compression (1.90 ± 0.62 vs 1.00 ± 0.45 mm, respectively, p = 0.04). With compression, the CBF demonstrated significantly greater mean ROM than the UF (2.82° ± 0.83° vs 2.170° ± 1.10°, p = 0.007). The final lordosis angle was greatest with CBF (3.74° ± 0.70°) and lowest with UF (2.68° ± 1.28°). This finding was statistically significant across all 3 conditions (p ≤ 0.04). CONCLUSIONS: Although UF/PF and CBF may require slightly more time and effort and incur more risk than UF, the potential improvement in sagittal balance may be worthwhile for select patients

    Dimensional Characterization of the Human Lumbar Interlaminar Space as a Guide for Safe Application of Minimally Invasive Dilators

    No full text
    BACKGROUND: The risk of interlaminar passage of a dilator into the lumbar spinal canal in minimally invasive approaches is currently unknown. Among anthropometric data reported in the medical literature, there is no cadaveric report of the interlaminar dimensions of the lumbar spine. OBJECTIVE: To report the lumbar interlaminar dimensions in neutral, flexion, and extension postures. METHODS: A total of 8 spines were sectioned into lumbar segments. Digitized coordinate data defining the locations and movements of chosen anatomic points on the laminar edges at a given spinal level were used to measure changes in the opening dimensions during static neutral posture and flexion-extension movements. Interlaminar dimensions were averaged and categorized for each vertebral level and spinal posture. RESULTS: The mean interlaminar distance increased from neutral posture to flexion across all vertebral levels. The mean interlaminar distances in the neutral posture ranged from 12.21 mm (L5-S1) to 14.88 mm (L1-L2). In flexion, the range was from 17.15 mm (L5-S1) to 18.50 mm (L4-L5). These measurements are greater than the first several diameters of dilators in all minimally invasive dilator sets. CONCLUSION: The precise measurements of the lumbar interlaminar space are valuable to minimally invasive spine surgeons for the dilatation phase of the operation. The risk of interlaminar passage of a minimally invasive dilator is greatest in flexion with dilators that have a diameter of 16 mm or less. There is considerably less risk of interlaminar passage in patients positioned on an extended Jackson table
    corecore