374 research outputs found

    Electron Removal Self Energy and its application to Ca2CuO2Cl2

    Full text link
    We propose using the self energy defined for the electron removal Green's function. Starting from the electron removal Green's function, we obtained expressions for the removal self energy Sigma^ER (k,omega) that are applicable for non-quasiparticle photoemission spectral functions from a single band system. Our method does not assume momentum independence and produces the self energy in the full k-omega space. The method is applied to the angle resolved photoemission from Ca_2CuO_2Cl_2 and the result is found to be compatible with the self energy value from the peak width of sharp features. The self energy is found to be only weakly k-dependent. In addition, the Im Sigma shows a maximum at around 1 eV where the high energy kink is located.Comment: 5 pages, 3 figure

    High resolution angle resolved photoemission studies on quasi-particle dynamics in graphite

    Full text link
    We obtained the spectral function of the graphite H point using high resolution angle resolved photoelectron spectroscopy (ARPES). The extracted width of the spectral function (inverse of the photo-hole lifetime) near the H point is approximately proportional to the energy as expected from the linearly increasing density of states (DOS) near the Fermi energy. This is well accounted by our electron-phonon coupling theory considering the peculiar electronic DOS near the Fermi level. And we also investigated the temperature dependence of the peak widths both experimentally and theoretically. The upper bound for the electron-phonon coupling parameter is ~0.23, nearly the same value as previously reported at the K point. Our analysis of temperature dependent ARPES data at K shows that the energy of phonon mode of graphite has much higher energy scale than 125K which is dominant in electron-phonon coupling.Comment: 9 pages, 8 figures, accepted for publication in Phys. Rev.

    Observation of inhibited electron-ion coupling in strongly heated graphite

    Get PDF
    Creating non-equilibrium states of matter with highly unequal electron and lattice temperatures (Tele≠Tion) allows unsurpassed insight into the dynamic coupling between electrons and ions through time-resolved energy relaxation measurements. Recent studies on low-temperature laser-heated graphite suggest a complex energy exchange when compared to other materials. To avoid problems related to surface preparation, crystal quality and poor understanding of the energy deposition and transport mechanisms, we apply a different energy deposition mechanism, via laser-accelerated protons, to isochorically and non-radiatively heat macroscopic graphite samples up to temperatures close to the melting threshold. Using time-resolved x ray diffraction, we show clear evidence of a very small electron-ion energy transfer, yielding approximately three times longer relaxation times than previously reported. This is indicative of the existence of an energy transfer bottleneck in non-equilibrium warm dense matter

    Verifying Quantitative Reliability of Programs That Execute on Unreliable Hardware

    Get PDF
    Emerging high-performance architectures are anticipated to contain unreliable components that may exhibit soft errors, which silently corrupt the results of computations. Full detection and recovery from soft errors is challenging, expensive, and, for some applications, unnecessary. For example, approximate computing applications (such as multimedia processing, machine learning, and big data analytics) can often naturally tolerate soft errors. In this paper we present Rely, a programming language that enables developers to reason about the quantitative reliability of an application -- namely, the probability that it produces the correct result when executed on unreliable hardware. Rely allows developers to specify the reliability requirements for each value that a function produces. We present a static quantitative reliability analysis that verifies quantitative requirements on the reliability of an application, enabling a developer to perform sound and verified reliability engineering. The analysis takes a Rely program with a reliability specification and a hardware specification, that characterizes the reliability of the underlying hardware components, and verifies that the program satisfies its reliability specification when executed on the underlying unreliable hardware platform. We demonstrate the application of quantitative reliability analysis on six computations implemented in Rely.This research was supported in part by the National Science Foundation (Grants CCF-0905244, CCF-1036241, CCF-1138967, CCF-1138967, and IIS-0835652), the United States Department of Energy (Grant DE-SC0008923), and DARPA (Grants FA8650-11-C-7192, FA8750-12-2-0110)

    Quasi-coherent fluctuation measurement with the upgraded microwave imaging reflectometer in KSTAR

    Get PDF
    The microwave imaging reflectometer (MIR) is the leading diagnostic tool for study of density fluctuations in KSTAR. For last three years since 2014, major components such as the multi-frequency probe beam source, multi-channel detector array, signal processing electronic system, data acquisition system, and optical system have been gradually upgraded. In this paper, the detailed system upgrade with test results in the laboratory and/or plasma is given, and analysis results of a distinctive fluctuation structure referred to as the quasi-coherent mode (QCM) measured by the upgraded MIR system for an L-mode discharge are presented. Cross-coherence analysis with multiple channels shows that the QCM is localized in a core region and appears to be driven by electron temperature gradient for the discharg

    Quasi 3D ECE imaging system for study of MHD instabilities in KSTAR

    Get PDF
    A second electron cyclotron emission imaging (ECEI) system has been installed on the KSTAR tokamak, toroidally separated by 1/16th of the torus from the first ECEI system. For the first time, the dynamical evolutions of MHD instabilities from the plasma core to the edge have been visualized in quasi-3D for a wide range of the KSTAR operation (B0 = 1.7???3.5 T). This flexible diagnostic capability has been realized by substantial improvements in large-aperture quasi-optical microwave components including the development of broad-band polarization rotators for imaging of the fundamental ordinary ECE as well as the usual 2nd harmonic extraordinary ECE.open1

    Piezo voltage controlled planar hall effect devices

    Get PDF
    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials

    Electron-Phonon Interactions in Graphene, Bilayer Graphene, and Graphite

    Full text link
    Using first-principles techniques, we calculate the renormalization of the electron Fermi velocity and the vibrational lifetimes arising from electron-phonon interactions in doped bilayer graphene and in graphite and compare the results with the corresponding quantities in graphene. For similar levels of doping, the Fermi velocity renormalization in bilayer graphene and in graphite is found to be approximately 30% larger than that in graphene. In the case of bilayer graphene, this difference is shown to arise from the interlayer interaction. We discuss our findings in the light of recent photoemission and Raman spectroscopy experiments.Comment: 6 pages, 4 figure
    corecore