2,129 research outputs found
Multiplexable Kinetic Inductance Detectors
We are starting to investigate a novel multiplexable readout method that can be applied to a large class of superconducting pair-breaking detectors. This readout method is completely different from those currently used with STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution. The readout is based on the fact that the kinetic surface inductance L_s of a superconductor is a function of the density of quasiparticles n, even at temperatures far below T_c. An efficient way to measure changes in the kinetic inductance is to monitor the transmission phase of a resonant circuit. By working at microwave frequencies and using thin films, the kinetic inductance can be a significant part of the total inductance L, and the volume of the inductor can be made quite small, on the order of 1 µm^3. As is done with other superconducting detectors, trapping could be used to concentrate the quasiparticles into the small volume of the inductor. However, the most intriguing aspect of the concept is that passive frequency multiplexing could be used to read out ~10^3 detectors with a single HEMT amplifier
Development of Low Noise THz SIS Mixer Using an Array of Nb/Al-AlN/NbTiN Junctions
We report the development of a low noise and broadband SIS mixer aimed for 1 THz channel of the Caltech Airborne Submillimeter Interstellar Medium Investigations Receiver (CASIMIR), designed for the Stratospheric Observatory for Infrared Astronomy, (SOFIA). The mixer uses an array of two 0.24 mum^2 Nb/Al-AlN/NbTiN SIS junctions with the critical current density of 30-50 kA/cm^2 . An on-chip double slot planar antenna couples the mixer circuit with the telescope beam. The mixer matching circuit is made with Nb and gold films. The mixer IF circuit is designed to cover 4-8 GHz band. A test receiver with the new mixer has a low noise operation in 0.87-1.12 THz band. The minimum receiver noise measured in our experiment is 353 K (Y = 1.50). The receiver noise corrected for the loss in the LO injection beam splitter is 250 K. The combination of a broad operation band of about 250 GHz with a low receiver noise makes the new mixer a useful element for application at SOFIA
Recommended from our members
Networked markets and relational contracts
Empirical studies of commercial relationships between firms reveal that (i) suppliers encounter situations in which they can gain in the short run by acting opportunistically---for example, delivering a lower quality than promised after being paid; and (ii) good conduct is sustained not exclusively by formal contracts but through informal relationships and the expectation of future business. In such relationships, the need to offer each supplier a large enough share of future business to deter cheating limits the number of supply relationships each buyer can sustain. The market thus becomes networked, with trade restricted to durable relationships. We propose and analyze a simple dynamic model to examine the structure of such overlapping relational contracts in equilibrium. Due to exogenous stochastic shocks, suppliers are not always able to make good on their promises even if they wish to, and so links are constantly dissolving and new ones are forming to take their place. This induces a Markov process on networks. We study how the stationary distribution over networks depends on the parameters---most importantly, the value of trade and the probability of shocks. When the rate at which shocks hit increases, as might happen during an economic downturn, maintaining incentive compatibility with suppliers requires promising each more future business and this necessitates maintaining fewer relationships with suppliers. This results in a destruction of social capital, and even if the rate of shocks later returns to its former level, it can take considerable time for social capital to be rebuilt because of search frictions. This creates a novel way for shocks to be persistent. It also suggests new connections between the theory of relational contracting, on the one hand, and the macroeconomic analysis of recessions, on the other
Low Noise 1 THz–1.4 THz Mixers Using Nb/Al-AlN/NbTiN SIS Junctions
We present the development of a low noise 1.2 THz and 1.4 THz SIS mixers for heterodyne spectrometry on the Stratospheric Observatory For Infrared Astronomy (SOFIA) and Herschel Space Observatory. This frequency range is above the limit for the commonly used Nb quasi particle SIS junctions, and a special type of hybrid Nb/AlN/NbTiN junctions has been developed for this project.We are using a quasi-optical mixer design with two Nb/AlN/NbTiN junctions with an area of 0.25 µm^2. The SIS junction tuning circuit is made of Nb and gold wire layers. At 1.13 THz the minimum SIS receiver uncorrected noise temperature is 450 K. The SIS receiver noise corrected for the loss in the LO coupler and in the cryostat optics is 350–450 K across 1.1–1.25 THz band. The receiver has a uniform sensitivity in a full 4–8 GHz IF band.
The 1.4 THz SIS receiver test at 1.33–1.35 THz gives promising results, although limited by the level of available LO power. Extrapolation of the data obtained with low LO power level shows a possibility to reach 500 K DSB receiver noise using already existing SIS mixer
Fabrication of wide-IF 200–300 GHz superconductor–insulator–superconductor mixers with suspended metal beam leads formed on silicon-on-insulator
We report on a fabrication process that uses SOI substrates and micromachining techniques to form wide-IF SIS mixer devices that have suspended metal beam leads for rf grounding. The mixers are formed on thin 25 µm membranes of Si, and are designed to operate in the 200–300 GHz band. Potential applications are in tropospheric chemistry, where increased sensitivity detectors and wide-IF bandwidth receivers are desired. They will also be useful in astrophysics to monitor absorption lines for CO at 230 GHz to study distant, highly redshifted galaxies by reducing scan times. Aside from a description of the fabrication process, electrical measurements of these Nb/Al–AlNx/Nb trilayer devices will also be presented. Since device quality is sensitive to thermal excursions, the new beam lead process appears to be compatible with conventional SIS device fabrication technology
Sub micron area Nb/AlO(x)/Nb tunnel junctions for submillimeter mixer applications
In this paper, we report on a fabrication process developed for submicron area tunnel junctions. We have fabricated Nb/AlO(x)/Nb tunnel junctions with areas down to 0.1 sq micron using these techniques. The devices have shown excellent performance in receiver systems up to 500 GHz and are currently in use in radio astronomy observatories at 115, 230, and 500 GHz
Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allow the location of the interaction to be determined with ≲ 1mm resolution at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly pixelized athermal phonon sensors for ∼1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering
Quasiparticle Trapping in Microwave Kinetic Inductance Strip Detectors
Microwave Kinetic Inductance Detectors (MKIDs) are thin-film, superconducting resonators, which are attractive for making large detector arrays due to their natural frequency domain multiplexing at GHz frequencies. For X-ray to IR wavelengths, MKIDs can provide high-resolution energy and timing information for each incoming photon. By fabricating strip detectors consisting of a rectangular absorber coupled to MKIDs at each end, high quantum efficiency and spatial resolution can be obtained. A similar geometry is being pursued for phonon sensing in a WIMP dark matter detector. Various materials have been tested including tantalum, tin, and aluminum for the absorbing strip, and aluminum, titanium, and aluminum manganese for the MKID. Initial Ta/Al X-ray devices have shown energy resolutions as good as 62 eV at 6 keV. A Ta/Al UV strip detector with an energy resolution of 0.8 eV at 4.9 eV has been demonstrated, but we find the coupling of the MKIDs to the absorbers is unreliable for these thinner devices. We report on progress probing the thicknesses at which the absorber/MKID coupling begins to degrade by using a resonator to inject quasiparticles directly into the absorber. In order to eliminate the absorber/MKID interface, a modified design for implanted AlMn/Al UV strip detectors was developed, and results showing good transmission of quasiparticles from the absorber to MKID in these devices are presented
- …