73 research outputs found

    Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

    Get PDF
    BACKGROUND: It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. METHODS: The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm(3 )ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. RESULTS: The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. CONCLUSION: Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans

    Genes as Tags: The Tax Implications of Widely Available Genetic Information

    Get PDF
    This paper examines how progress in genetics\u27 specifically, the proliferation of knowledge about the human genome\u27 may influence the feasibility and desirability of a tax that is based on individual human endowments or ability. The paper explores various forms that such a genetic endowment tax-and-transfer regime might take and identifies some of the benefits and costs of such a regime. The authors take no position on whether a genetic endowment tax would be desirable or not. However, one contribution of the paper is to observe that current law in the U.S., which restricts the use of genetic information by insurers and employers, is equivalent to a form of genetic endowment tax. The paper also notes that, in the absence of a government-mandated transfer policy with respect to genetic endowments, private insurance markets may arise to fill the gap, allowing individuals to purchase insurance against the possibility of a bad genetic draw

    Simultaneous Recruitment of Drug Users and Men Who Have Sex with Men in the United States and Russia Using Respondent-Driven Sampling: Sampling Methods and Implications

    Get PDF
    The Sexual Acquisition and Transmission of HIV Cooperative Agreement Program (SATHCAP) examined the role of drug use in the sexual transmission of the human immunodeficiency virus (HIV) from traditional high-risk groups, such as men who have sex with men (MSM) and drug users (DU), to lower risk groups in three US cities and in St. Petersburg, Russia. SATHCAP employed respondent-driven sampling (RDS) and a dual high-risk group sampling approach that relied on peer recruitment for a combined, overlapping sample of MSM and DU. The goal of the sampling approach was to recruit an RDS sample of MSM, DU, and individuals who were both MSM and DU (MSM/DU), as well as a sample of sex partners of MSM, DU, and MSM/DU and sex partners of sex partners. The approach efficiently yielded a sample of 8,355 participants, including sex partners, across all four sites. At the US sites—Los Angeles, Chicago, and Raleigh–Durham—the sample consisted of older (mean age = 41 years), primarily black MSM and DU (both injecting and non-injecting); in St. Petersburg, the sample consisted of primarily younger (mean age = 28 years) MSM and DU (injecting). The US sites recruited a large proportion of men who have sex with men and with women, an important group with high potential for establishing a generalized HIV epidemic involving women. The advantage of using the dual high-risk group approach and RDS was, for the most part, the large, efficiently recruited samples of MSM, DU, and MSM/DU. The disadvantages were a recruitment bias by race/ethnicity and income status (at the US sites) and under-enrollment of MSM samples because of short recruitment chains (at the Russian site)

    Elevated basal serum tryptase identifies a multisystem disorder associated with increased TPSAB1 copy number

    Get PDF
    Elevated basal serum tryptase levels are present in 4-6% of the general population, but the cause and relevance of such increases are unknown. Previously, we described subjects with dominantly inherited elevated basal serum tryptase levels associated with multisystem complaints including cutaneous flushing and pruritus, dysautonomia, functional gastrointestinal symptoms, chronic pain, and connective tissue abnormalities, including joint hypermobility. Here we report the identification of germline duplications and triplications in the TPSAB1 gene encoding α-tryptase that segregate with inherited increases in basal serum tryptase levels in 35 families presenting with associated multisystem complaints. Individuals harboring alleles encoding three copies of α-tryptase had higher basal serum levels of tryptase and were more symptomatic than those with alleles encoding two copies, suggesting a gene-dose effect. Further, we found in two additional cohorts (172 individuals) that elevated basal serum tryptase levels were exclusively associated with duplication of α-tryptase-encoding sequence in TPSAB1, and affected individuals reported symptom complexes seen in our initial familial cohort. Thus, our findings link duplications in TPSAB1 with irritable bowel syndrome, cutaneous complaints, connective tissue abnormalities, and dysautonomia

    Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

    No full text
    Abstract Background It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. Methods The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. Results The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. Conclusion Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.</p
    corecore