26 research outputs found

    Pedestrian Injury and Human Behaviour: Observing Road-Rule Violations at High-Incident Intersections

    Get PDF
    Background Human behaviour is an obvious, yet under-studied factor in pedestrian injury. Behavioural interventions that address rule violations by pedestrians and motorists could potentially reduce the frequency of pedestrian injury. In this study, a method was developed to examine road-rule non-compliance by pedestrians and motorists. The purpose of the study was to examine the potential association between violations made by pedestrians and motorists at signalized intersections, and collisions between pedestrians and motor-vehicles. The underlying hypothesis is that high-incident pedestrian intersections are likely to vary with respect to their aetiology, and thus are likely to require individualized interventions – based on the type and rate of pedestrian and motorist violation. Methods High-incident pedestrian injury intersections in Vancouver, Canada were identified using geographic information systems. Road-rule violations by pedestrians and motorists were documented at each incident hotspot by a team of observers at several different time periods during the day. Results Approximately 9,000 pedestrians and 18,000 vehicles were observed in total. In total for all observed intersections, over 2000 (21%) pedestrians committed one of the observed pedestrian road-crossing violations, while approximately 1000 (5.9%) drivers committed one of the observed motorist violations. Great variability in road-rule violations was observed between intersections, and also within intersections at different observation periods. Conclusions Both motorists and pedestrians were frequently observed committing road-rule violations at signalized intersections, suggesting a potential human behavioural contribution to pedestrian injury at the study sites. These results suggest that each intersection may have unique mechanisms that contribute to pedestrian injury, and may require targeted behavioural interventions. The method described in this study provides the basis for understanding the relationship between violations and pedestrian injury risk at urban intersections. Findings could be applied to targeted prevention campaigns designed to reduce the number of pedestrian injuries at signalized intersections

    Avaliação de doses referenciais obtidas com exames de tomografia computadorizada de feixe cônico adquiridos com diferentes tamanhos de voxel Evaluation of referential dosages obtained by Cone-Beam Computed Tomography examinations acquired with different voxel sizes

    Get PDF
    OBJETIVO: o objetivo deste estudo reside na avaliação do produto dose-área (DAP) e das doses de entrada na pele (DEP), empregando protocolos com tamanho de voxel diferente, obtidos com o aparelho de Tomografia Computadorizada de Feixe Cônico (TCFC) i-CAT, a fim de determinar melhores parâmetros baseados nos princípios da radioproteção. MÉTODOS: para medição do DEP foi utilizada uma câmara de ionização do tipo lápis, e para o DAP foi utilizado um aparelho PTW. Quatro protocolos foram testados, a saber: (1) 40 seg., voxel de 0,2mm e 46,72mAs; (2) 40 seg., voxel de 0,25mm e 46,72mAs; (3) 20 seg., voxel de 0,3mm e 23,87mAs; (4) 20 seg., voxel de 0,4mm e 23,87mAs. A quilovoltagem permaneceu constante (120KVp). RESULTADOS: detectou-se diferença estatisticamente significativa (p<0,001) entre os quatro protocolos, para os dois métodos de avaliação da dose de radiação (DAP e DEP). Na avaliação do DAP, os protocolos 2 e 3 promoveram uma diferença estatisticamente significativa, não sendo possível detectar qual dos protocolos na avaliação da DEP proporcionou esse resultado. CONCLUSÃO: DAP e DEP apresentam-se como métodos de avaliação para doses de radiação em tomografia computadorizada de feixe cônico, sendo necessários mais estudos para elucidar tal achado. O tamanho do voxel, isoladamente, não é capaz de interferir na dose de radiação em exames de TCFC (i-CAT). A dose de radiação para exames de TCFC (i-CAT) está diretamente relacionada ao tempo de exposição e à miliamperagem.<br>Objectives: The aim of this study was to evaluate the dose-area product (DAP) and the entrance skin dose (ESD), using protocols with different voxel sizes, obtained with i-CAT Cone-Beam Computed Tomography (CBCT), to determine the best parameters based on radioprotection principles. METHODS: A pencil-type ionization chamber was used to measure the ESD and a PTW device was used to measure the DAP. Four protocols were tested: (1) 40s, 0.2 mm voxel and 46.72 mAs; (2) 40s, 0.25 mm voxel and 46.72 mAs; (3) 20s, 0.3 mm voxel and 23.87 mAs; (4) 20s, 0.4 mm voxel and 23.87 mAs. The kilovoltage remained constant (120kVp). RESULTS: A significant statistical difference (p<0.001) was found among the four protocols for both methods of radiation dosage evaluation (DAP and ESD). For DAP evaluation, protocols 2 and 3 presented a statistically significant difference, and it was not possible to detect which of the protocols for ESD evaluation promoted this result. CONCLUSIONS: DAP and ESD are evaluation methods for radiation dose for Cone-Beam Computed Tomography, and more studies are necessary to explain such result. The voxel size alone does not affect the radiation dose in CBCT (i-CAT) examinations. The radiation dose for CBCT (i-CAT) examinations is directly related to the exposure time and milliamperes

    Análise de dentição mista: tomografia versus predição e medida radiográfica Mixed-dentition analysis: tomography versus radiographic prediction and measurement

    No full text
    OBJETIVO: o objetivo dos autores desse estudo foi comparar o método de análise de dentição mista que utiliza tomografia computadorizada de feixe cônico para avaliar os diâmetros dos dentes intraósseos com os métodos de Moyers, Tanaka-Johnston e radiografias oblíquas em 45º. MÉTODOS: foram realizadas medidas, na arcada inferior, dos diâmetros mesiodistais dos incisivos permanentes irrompidos, nos modelos de gesso com auxílio de paquímetro digital e estimativa do tamanho de pré-molares e caninos permanentes ainda não irrompidos utilizando-se a tabela de Moyers e a fórmula de predição de Tanaka-Johnston. Nas radiografias oblíquas em 45º, caninos e pré-molares foram medidos utilizando-se o mesmo instrumento. Nas tomografias, as mesmas unidades dentárias foram aferidas por meio de ferramentas do programa Dolphin. RESULTADOS: a análise estatística revelou elevada concordância entre o método tomográfico e o radiográfico, e baixa concordância entre o tomográfico e os demais avaliados. CONCLUSÃO: a tomografia computadorizada de feixe cônico mostrou-se confiável para análise da dentição mista e apresenta algumas vantagens em relação aos métodos comparados: a observação e mensuração dos dentes intraósseos individualmente, com a possibilidade, contudo, de visualizá-los sob diferentes perspectivas e sem superposição de estruturas anatômicas.<br>OBJECTIVE: The aim of this study was to evaluate the method for mixed-dentition analysis using Cone-Beam Computed Tomography for assessing the diameter of intra-osseous teeth and compare the results with those obtained by Moyers, Tanaka-Johnston, and 45-degree oblique radiographs. METHODS: Measurements of mesial-distal diameters of erupted lower permanent incisors were made on plaster cast models by using a digital calliper, whereas assessment of the size of non-erupted permanent pre-molars and canines was performed by using Moyer's table and Tanaka-Johnston's prediction formula. For 45-degree oblique radiographs, both canines and pre-molars were measured by using the same instrument. For tomographs, the same dental units were gauged by means of Dolphin software resources. RESULTS: Statistic analysis revealed high agreement between tomographic and radiographic methods, and low agreement between tomographs and other methods being evaluated. CONCLUSION: Cone-Beam Computed Tomography was accurate for mixed-dentition analysis in addition to presenting some advantages over compared measurement methods: observation and measurement of intra-osseous teeth individually with the possibility, however, to view them from different prospects and without superimposition of anatomical structures
    corecore