38,116 research outputs found

    Infrared heterodyne radiometer for airborne atmospheric transmittance measurements

    Get PDF
    An infrared heterodyne radiometer (IHR) was used to measure atmospheric transmittance at selected hydrogen fluoride (2.7 micrometer) and deuterium fluoride (3.8 micrometer) laser transitions. The IHR was installed aboard a KC-135 aircraft for an airborne atmospheric measurements program that used the sun as a backlighting source for the transmission measurements. The critical components are: a wideband indium antimonide (1nSb) photomixer, a CW HF/DF laser L0, a radiometric processor, and a 1900 K blackbody reference source. The measured heterodyne receiver sensitivity (NEP) is 1.3 x 10 to the -19th power W/Hz, which yields a calculated IHR temperature resolution accuracy of delta I sub S/-3 sub S = 0.005 for a source temperature of 1000 K and a total transmittance of 0.5. Measured atmospheric transmittance at several wavelengths and aircraft altitudes from 9.14 km (30,000 ft) to 13.72 km (45,000 ft) were obtained during the measurements program and have been compared with values predicted by the AFGL Atmospheric Line Parameter Compilation

    Shock-induced CO2 loss from CaCO3: Implications for early planetary atmospheres

    Get PDF
    Recovered samples from shock recovery experiments on single crystal calcite were subjected to thermogravimetric analysis to determine the amount of post-shock CO2, the decarbonization interval and the activation energy, for the removal of remaining CO2 in shock-loaded calcite. Comparison of post-shock CO2 with that initially present determines shock-induced CO2 loss as a function of shock pressure. Incipient to complete CO2 loss occurs over a pressure range of approximately 10 to approximately 70 GPa. Optical and scanning electron microscopy reveal structural changes, which are related to the shock-loading. The occurrence of dark, diffuse areas, which can be resolved as highly vesicular areas as observed with a scanning electron microscope are interpreted as representing quenched partial melts, into which shock-released CO2 was injected. The experimental results are used to constrain models of shock-produced, primary CO2 atmospheres on the accreting terrestrial planets

    Planck pre-launch status: The HFI instrument, from specification to actual performance

    Get PDF
    Context. The High Frequency Instrument (HFI) is one of the two focal instruments of the Planck mission. It will observe the whole sky in six bands in the 100 GHz−1 THz range. Aims. The HFI instrument is designed to measure the cosmic microwave background (CMB) with a sensitivity limited only by fundamental sources: the photon noise of the CMB itself and the residuals left after the removal of foregrounds. The two high frequency bands will provide full maps of the submillimetre sky, featuring mainly extended and point source foregrounds. Systematic effects must be kept at negligible levels or accurately monitored so that the signal can be corrected. This paper describes the HFI design and its characteristics deduced from ground tests and calibration. Methods. The HFI instrumental concept and architecture are feasible only by pushing new techniques to their extreme capabilities, mainly: (i) bolometers working at 100 mK and absorbing the radiation in grids; (ii) a dilution cooler providing 100 mK in microgravity conditions; (iii) a new type of AC biased readout electronics and (iv) optical channels using devices inspired from radio and infrared techniques. Results. The Planck-HFI instrument performance exceeds requirements for sensitivity and control of systematic effects. During ground-based calibration and tests, it was measured at instrument and system levels to be close to or better than the goal specification

    A low noise, high thermal stability, 0.1 K test facility for the Planck HFI bolometers

    Get PDF
    We are developing a facility which will be used to characterize the bolometric detectors for Planck, an ESA mission to investigate the Cosmic Microwave Background. The bolometers operate at 0.1 K, employing neutron-transmutation doped (NTD) Ge thermistors with resistances of several megohms to achieve NEPs~1×10^(–17) W Hz^(–1/2). Characterization of the intrinsic noise of the bolometers at frequencies as low as 0.010 Hz dictates a test apparatus thermal stability of 40 nK Hz^(–1/2) to that frequency. This temperature stability is achieved via a multi-stage isolation and control geometry with high resolution thermometry implemented with NTD Ge thermistors, JFET source followers, and dedicated lock-in amplifiers. The test facility accommodates 24 channels of differential signal readout, for measurement of bolometer V(I) characteristics and intrinsic noise. The test facility also provides for modulated radiation in the submillimeter band incident on the bolometers, for measurement of the optical speed-of-response; this illumination can be reduced below detectable limits without interrupting cryogenic operation. A commercial Oxford Instruments dilution refrigerator provides the cryogenic environment for the test facility

    Emissivity measurements of reflective surfaces at near-millimeter wavelengths

    Get PDF
    We have developed an instrument for directly measuring the emissivity of reflective surfaces at near-millimeter wavelengths. The thermal emission of a test sample is compared with that of a reference surface, allowing the emissivity of the sample to be determined without heating. The emissivity of the reference surface is determined by one’s heating the reference surface and measuring the increase in emission. The instrument has an absolute accuracy of Δe = 5 x 10^-4 and can reproducibly measure a difference in emissivity as small as Δe = 10^-4 between flat reflective samples. We have used the instrument to measure the emissivity of metal films evaporated on glass and carbon fiber-reinforced plastic composite surfaces. We measure an emissivity of (2.15 ± 0.4) x 10^-3 for gold evaporated on glass and (2.65 ± 0.5) x 10^-3 for aluminum evaporated on carbon fiber-reinforced plastic composite

    Systematic challenges for future gravitational wave measurements of precessing binary black holes

    Get PDF
    The properties of precessing, coalescing binary black holes are presently inferred through comparison with two approximate models of compact binary coalescence. In this work we show these two models often disagree substantially when binaries have modestly large spins (a0.4a\gtrsim 0.4) and modest mass ratios (q2q\gtrsim 2). We demonstrate these disagreements using standard figures of merit and the parameters inferred for recent detections of binary black holes. By comparing to numerical relativity, we confirm these disagreements reflect systematic errors. We provide concrete examples to demonstrate that these systematic errors can significantly impact inferences about astrophysically significant binary parameters. For the immediate future, parameter inference for binary black holes should be performed with multiple models (including numerical relativity), and carefully validated by performing inference under controlled circumstances with similar synthetic events.Comment: 12 pages, 9 figure
    corecore