703 research outputs found
Test of a Liquid Argon TPC in a magnetic field and investigation of high temperature superconductors in liquid argon and nitrogen
Tests with cosmic ray muons of a small liquid argon time projection chamber
(LAr TPC) in a magnetic field of 0.55 T are described. No effect of the
magnetic field on the imaging properties were observed. In view of a future
large, magnetized LAr TPC, we investigated the possibility to operate a high
temperature superconducting (HTS) solenoid directly in the LAr of the detector.
The critical current of HTS cables in an external magnetic field was
measured at liquid nitrogen and liquid argon temperatures and a small prototype
HTS solenoid was built and tested.Comment: 5 pages, 5 figures, to appear in Proc. of 1st International Workshop
towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba
(Japan), March 201
First operation of a liquid Argon TPC embedded in a magnetic field
We have operated for the first time a liquid Argon TPC immersed in a magnetic
field up to 0.55 T. We show that the imaging properties of the detector are not
affected by the presence of the magnetic field. The magnetic bending of the
ionizing particle allows to discriminate their charge and estimate their
momentum. These figures were up to now not accessible in the non-magnetized
liquid Argon TPC.Comment: 9 pages, 3 figure
Feasibility of high-voltage systems for a very long drift in liquid argon TPCs
Designs of high-voltage (HV) systems for creating a drift electric field in
liquid argon TPCs are reviewed. In ongoing experiments systems capable of
approx. 100 kV are realised for a drift field of 0.5-1 kV/cm over a length of
up to 1.5 m. Two of them having different approaches are presented: (1) the
ICARUS-T600 detector having a system consisting of an external power supply, HV
feedthroughs and resistive voltage degraders and (2) the ArDM-1t detector
having a cryogenic Greinacher HV multiplier inside the liquid argon volume. For
a giant scale liquid argon TPC, a system providing 2 MV may be required to
attain a drift length of approx. 20 m. Feasibility of such a system is
evaluated by extrapolating the existing designs.Comment: 8 pages, 13 figures, to appear in Proc. of 1st International Workshop
towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba
(Japan), March 201
High-Temperature Superconducting Level Meter for Liquid Argon Detectors
Capacitive devices are customarily used as probes to measure the level of
noble liquids in detectors operated for neutrino studies and dark matter
searches. In this work we describe the use of a high-temperature
superconducting material as an alternative to control the level of a cryogenic
noble liquid. Lab measurements indicate that the superconductor shows a linear
behaviour, a high degree of stability and offers a very accurate determination
of the liquid volume. This device is therefore a competitive instrument and
shows several advantages over conventional level meters.Comment: 13 pages, 11 figures. Accepted for publication in JINS
What it takes to measure a fundamental difference between dark matter and baryons: the halo velocity anisotropy
Numerous ongoing experiments aim at detecting WIMP dark matter particles from
the galactic halo directly through WIMP-nucleon interactions. Once such a
detection is established a confirmation of the galactic origin of the signal is
needed. This requires a direction-sensitive detector. We show that such a
detector can measure the velocity anisotropy beta of the galactic halo.
Cosmological N-body simulations predict the dark matter anisotropy to be
nonzero, beta~0.2. Baryonic matter has beta=0 and therefore a detection of a
nonzero beta would be strong proof of the fundamental difference between dark
and baryonic matter. We estimate the sensitivity for various detector
configurations using Monte Carlo methods and we show that the strongest signal
is found in the relatively few high recoil energy events. Measuring beta to the
precision of ~0.03 will require detecting more than 10^4 WIMP events with
nuclear recoil energies greater than 100 keV for a WIMP mass of 100 GeV and a
32S target. This number corresponds to ~10^6 events at all energies. We discuss
variations with respect to input parameters and we show that our method is
robust to the presence of backgrounds and discuss the possible improved
sensitivity for an energy-sensitive detector.Comment: 15 pages, 8 figures, accepted by JCAP. Matches accepted versio
Direct WIMP identification: Physics performance of a segmented noble-liquid target immersed in a Gd-doped water veto
We evaluate background rejection capabilities and physics performance of a
detector composed of two diverse elements: a sensitive target (filled with one
or two species of liquefied noble gasses) and an active veto (made of Gd-doped
ultra-pure water). A GEANT4 simulation shows that for a direct WIMP search,
this device can reduce the neutron background to O(1) event per year per tonne
of material. Our calculation shows that an exposure of one tonne year
will suffice to exclude spin-independent WIMP-nucleon cross sections ranging
from pb to pb.Comment: 17 pages, 5 figures. Version accepted for publication in JCA
La población infantil de la Motilla del Azuer: Un estudio bioarqueológico
Our main goal in this paper is the analysis of children through funerary record at the archaeological Bronze Age site of La Motilla del Azuer, Daimiel, in La Mancha area. We have chosen a settlement with high-quality archaeological and anthropological data, and a precise methodology of excavation, documentation and contextualization allow us to formulate cultural hypothesis and understand the roles of different members of the social group, not only due to sex and age identities but also to economic and social positions.Nuestro principal objetivo en este texto es el análisis de la población infantil a través del registro funerario del yacimiento arqueológico de la Edad del Bronce de la Motilla del Azuer, situada en Daimiel, en la región de La Mancha. Se ha seleccionado un yacimiento que posee datos antropológicos adecuados y un registro arqueológico solvente, basado en una cuidada metodología de excavación, documentación y contextualización de los restos antropológicos. Todo ello nos permite formular propuestas de carácter cultural y entender los roles que jugaron los diferentes individuos tanto por condicionamientos derivados del sexo y la edad como por causas económicas y sociales
- …
