16 research outputs found
The effects of a muscle resistance program on the functional capacity, knee extensor muscle strength and plasma levels of IL-6 and TNF-α in pre-frail elderly women: a randomized crossover clinical trial - a study protocol
<p>Abstract</p> <p>Background</p> <p>With the increase in the elderly population, a growing number of chronic degenerative diseases and a greater dependency on caregivers have been observed. Elderly persons in states of frailty remain more susceptible to significant health complications. There is evidence of an inverse relationship between plasma levels of inflammatory mediators and levels of functionality and muscle strength, suggesting that muscle-strengthening measures can aid in inflammatory conditions. The purpose of this study will be verified the effect of a muscle-strengthening program with load during a ten-week period in pre-frail elderly women with attention to the following outcomes: (1) plasma levels of interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-α), (2) functional capacity and (3) knee extensor muscle strength.</p> <p>Methods/Design</p> <p>The study design is a randomized crossover clinical trial evaluating 26 elderly women (regardless of their race and/or social condition) who are community residents, older than 65, and classified as pre-frail according to the criteria previously described by Fried et al. (2004). All subjects will be assessed using the Timed up and go and 10-Meter Walk Test functional tests. The plasma levels of IL-6 and TNF-α will be assessed by ELISA (<it>enzyme-linked immunosorbent assay</it>) with high sensitivity kits (Quantikine<sup>®</sup>HS, R&D Systems Minneapolis, MN, U.S.). Knee extensor muscle strength will be assessed using the <it>Byodex System 3 Pro</it><sup><it>® </it></sup>isokinetic dynamometer at angular speeds of 60 and 180°/s. The intervention will consist of strengthening exercises of the lower extremities at 50 to 70% of 1RM (maximal resistance) three times per week for ten weeks. The volunteers will be randomized into two groups: group E, the intervention group, and group C, the control group that did not initiate any new activities during the initial study period (ten weeks). After the initial period, group C will begin the intervention and group E will maintain everyday activities without exercising. At the end of the total study period, all volunteers will be reassessed.</p> <p>Discussion</p> <p>To demonstrate and discuss possible influences of load-bearing exercises on the modification of plasma levels of IL-6 and TNF-α and in the functional performance of pre-frail elderly women.</p> <p>Trial Registration</p> <p>ISRCTN62824599</p
Posterior shoulder tightness; an intersession reliability study of 3 clinical tests.
Background Although posterior shoulder tightness (PST) has been associated with shoulder pathology and altered glenohumeral joint kinematics, uncertainty remains regarding its cause and definition. To understand the efficacy of treatments for PST, it must be possible to identify people with PST for the purposes of research and clinical decision-making. Clinical tests for PST must demonstrate acceptable levels of measurement reliability in order to identify the condition and to evaluate the response to intervention. There is currently a lack of research describing intersession reliability for measures of PST. The aim of this study was to quantify the inter-session reliability for three clinical tests used to identify PST over a 6–10 week interval. Methods A convenience sample of 26 asymptomatic adult participants (52 shoulders) were recruited from a university setting over a five-month duration. Participants attended the human movement laboratory for measurement of glenohumeral joint internal rotation, horizontal adduction and low flexion on two occasions separated by an interval of 6–10 weeks. Intra-class correlation coefficients were calculated from the mean square values derived from the within-subject, single factor (repeated measures) ANOVA. Test-retest measurement stability was evaluated by calculating the standard error of measurement and the minimum detectable change for each measurement. Results All 3 tests demonstrated good intersession intra-rater reliability (0.86–0.88), and the standard error of measurement (95%) were 7.3° for glenohumeral horizontal adduction, 9.4° for internal rotation, and 6.9° for low flexion. The minimum detectable change for glenohumeral horizontal adduction was 10.2°, internal rotation was 13.3°, and low flexion was 9.7°. Conclusion In this population of people without symptoms, the 3 measures of PST all demonstrated acceptable inter-session reliability. The standard error of measurement and minimum detectable change results can be used to determine if a change in measures of PST are due to measurement error or an actual change over time.Peer reviewe
Health Research Profile to assess the capacity of low and middle income countries for equity-oriented research
BACKGROUND: The Commission on Health Research for Development concluded that "for the most vulnerable people, the benefits of research offer a potential for change that has gone largely untapped." This project was designed to assess low and middle income country capacity and commitment for equity-oriented research. METHODS: A multi-disciplinary team with coordinators from each of four regions (Asia, Latin America, Africa and Central and Eastern Europe) developed a questionnaire through consensus meetings using a mini-Delphi technique. Indicators were selected based on their quality, validity, comprehensiveness, feasibility and relevance to equity. Indicators represented five categories that form the Health Research Profile (HRP): 1) Research priorities; 2) Resources (amount spent on research); 3) Production of knowledge (capacity); 4) Packaging of knowledge and 5) Evidence of research impact on policy and equity. We surveyed three countries from each region. RESULTS: Most countries reported explicit national health research priorities. Of these, half included specific research priorities to address inequities in health. Data on financing were lacking for most countries due to inadequate centralized collection of this information. The five main components of HRP showed a gradient where countries scoring lower on the Human Development Index (HDI) had a lower capacity to conduct research to meet local health research needs. Packaging such as peer-reviewed journals and policy forums were reported by two thirds of the countries. Seven out of 12 countries demonstrated impact of health research on policies and reported engagement of stakeholders in this process. CONCLUSION: Only one out of 12 countries indicated there was research on all fronts of the equity debate. Knowledge sharing and management is needed to strengthen within-country capacity for research and implementation to reduce inequities in health. We recommend that all countries (and external agencies) should invest more in building a certain minimum level of national capacity for equity-oriented research
The reliability of side to side measurements of upper extremity activity levels in healthy subjects
<p>Abstract</p> <p>Background</p> <p>In both clinical and occupational settings, ambulatory sensors are becoming common for assessing all day measurements of arm motion. In order for the motion of a healthy, contralateral side to be used as a control for the involved side, the inherent side to side differences in arm usage must be minimal. The goal of the present study was to determine the reliability of side to side measurements of upper extremity activity levels in healthy subjects.</p> <p>Methods</p> <p>Thirty two subjects with no upper extremity pathologies were studied. Each subject wore a triaxial accelerometer on both arms for three and a half hours. Motion was assessed using parameters previously reported in the literature. Side to side differences were compared with the intraclass correlation coefficient, standard error of the mean, minimal detectable change scores and a projected sample size analysis.</p> <p>Results</p> <p>The variables were ranked based on their percentage of minimal detectable change scores and sample sizes needed for paired t-tests. The order of these rankings was found to be identical and the top ranked parameters were activity counts per hour (MDC% = 9.5, n = 5), jerk time (MDC% = 15.8, n = 8) and percent time above 30 degrees (MDC% = 34.7, n = 9).</p> <p>Conclusions</p> <p>In general, the mean activity levels during daily activities were very similar between dominant and non-dominant arms. Specifically, activity counts per hour, jerk time, and percent time above 30 degrees were found to be the variables most likely to reveal significant difference or changes in both individuals and groups of subjects. The use of ambulatory measurements of upper extremity activity has very broad uses for occupational assessments, musculoskeletal injuries of the shoulder, elbow, wrist and hand as well as neurological pathologies.</p