34 research outputs found
Recommended from our members
The effects of process parameters on injection-molded PZT ceramics part fabrication- compounding process rheology.
Solid solutions of lead-based perovskites are the backbone materials of the piezoelectric components for transducer, actuator, and resonator applications. These components, typically small in size, are fabricated from large sintered ceramic slugs using grinding and lapping processes. These operations increase manufacturing costs and produce a large hazardous waste stream, especially when component size decreases. To reduce costs and hazardous wastes associated with the production of these components, an injection molding technique is being investigated to replace the machining processes. The first step in the new technique is to compound an organic carrier with a ceramic powder. The organic carrier is a thermoplastic based system composed of a main carrier, a binder, and a surfactant. Understanding the rheology of the compounded material is necessary to minimize the creation of defects such as voids or cavities during the injection-molding process. An experiment was performed to model the effects of changes in the composition and processing of the material on the rheological behavior. Factors studied included: the surfactant of the organic carrier system, the solid loading of the compounded material, and compounding time. The effects of these factors on the viscosity of the material were investigated
Relationships among HIV infection, metabolic risk factors, and left ventricular structure and function
Our objective was to determine if the presence of metabolic complications (MC) conveyed an additional risk for left ventricular (LV) dysfunction in people with HIV. HIV(+) and HIV(−) men and women were categorized into four groups: (1) HIV(+) with MC (43±7 years, n=64), (2) HIV(+) without MC (42±7 years, n=59), (3) HIV(−) with MC (44±8 years, n=37), or (4) HIV(−) controls without MC (42±8 years, n=41). All participants underwent two-dimensional (2-D), Doppler, and tissue Doppler echocardiography. Overall, the prevalence of systolic dysfunction (15 vs. 4%, p=0.02) and LV hypertrophy (9 vs. 1%, p=0.03) was greater in HIV(+) than in HIV(−) participants. Participants with MC had a greater prevalence of LV hypertrophy (10% vs. 1%). Early mitral annular velocity during diastole was significantly (p<0.005) lower in groups with MC (HIV(+)/MC(+): 11.6±2.3, HIV(−)/MC(+): 12.0±2.3 vs. HIV(+)/MC(−): 12.4±2.3, HIV(−)/MC(−): 13.1±2.4 cm/s) and tended to be lower in groups with HIV (p=0.10). However, there was no interaction effect of HIV and MC for any systolic or diastolic variable. Regardless of HIV status, participants with MC had reduced LV diastolic function. Although both the presence of MC and HIV infection were associated with lower diastolic function, there was no additive negative effect of HIV on diastolic function beyond the effect of MC. Also, HIV was independently associated with lower systolic function. Clinical monitoring of LV function in individuals with metabolic risk factors, regardless of HIV status, is warranted
Recommended from our members
Mold-filling experiments for validation of modeling encapsulation. Part 1, "wine glass" mold.
The C6 project 'Encapsulation Processes' has been designed to obtain experimental measurements for discovery of phenomena critical to improving these processes, as well as data required in the verification and validation plan (Rao et al. 2001) for model validation of flow in progressively complex geometries. We have observed and recorded the flow of clear, Newtonian liquids and opaque, rheologically complex suspensions in two mold geometries. The first geometry is a simple wineglass geometry in a cylinder and is reported here in Part 1. The results in a more realistic encapsulation geometry are reported in Part 2
Recommended from our members
Foam process models.
In this report, we summarize our work on developing a production level foam processing computational model suitable for predicting the self-expansion of foam in complex geometries. The model is based on a finite element representation of the equations of motion, with the movement of the free surface represented using the level set method, and has been implemented in SIERRA/ARIA. An empirically based time- and temperature-dependent density model is used to encapsulate the complex physics of foam nucleation and growth in a numerically tractable model. The change in density with time is at the heart of the foam self-expansion as it creates the motion of the foam. This continuum-level model uses an homogenized description of foam, which does not include the gas explicitly. Results from the model are compared to temperature-instrumented flow visualization experiments giving the location of the foam front as a function of time for our EFAR model system
Recommended from our members
New composite separator pellet to increase power density and reduce size of thermal batteries.
We show that it is possible to manufacture strong macroporous ceramic films that can be backfilled with electrolyte to form rigid separator pellets suitable for use in thermal batteries. Several new ceramic manufacturing processes are developed to produce sintered magnesium oxide foams with connected porosities of over 80% by volume and with sufficient strength to withstand the battery manufacturing steps. The effects of processing parameters are quantified, and methods to imbibe electrolyte into the ceramic scaffold demonstrated. Preliminary single cell battery testing show that some of our first generation pellets exhibit longer voltage life with comparable resistance at the critical early times to that exhibited by a traditional pressed pellets. Although more development work is needed to optimize the processes to create these rigid separator pellets, the results indicate the potential of such ceramic separator pellets to be equal, if not superior to, current pressed pellets. Furthermore, they could be a replacement for critical material that is no longer available, as well as improving battery separator strength, decreasing production costs, and leading to shorter battery stacks for long-life batteries
Recommended from our members
Modeling injection molding of net-shape active ceramic components.
To reduce costs and hazardous wastes associated with the production of lead-based active ceramic components, an injection molding process is being investigated to replace the current machining process. Here, lead zirconate titanate (PZT) ceramic particles are suspended in a thermoplastic resin and are injected into a mold and allowed to cool. The part is then bisque fired and sintered to complete the densification process. To help design this new process we use a finite element model to describe the injection molding of the ceramic paste. Flow solutions are obtained using a coupled, finite-element based, Newton-Raphson numerical method based on the GOMA/ARIA suite of Sandia flow solvers. The evolution of the free surface is solved with an advanced level set algorithm. This approach incorporates novel methods for representing surface tension and wetting forces that affect the evolution of the free surface. Thermal, rheological, and wetting properties of the PZT paste are measured for use as input to the model. The viscosity of the PZT is highly dependent both on temperature and shear rate. One challenge in modeling the injection process is coming up with appropriate constitutive equations that capture relevant phenomenology without being too computationally complex. For this reason we model the material as a Carreau fluid and a WLF temperature dependence. Two-dimensional (2D) modeling is performed to explore the effects of the shear in isothermal conditions. Results indicate that very low viscosity regions exist near walls and that these results look similar in terms of meniscus shape and fill times to a simple Newtonian constitutive equation at the shear-thinned viscosity for the paste. These results allow us to pick a representative viscosity to use in fully three-dimensional (3D) simulation, which because of numerical complexities are restricted to using a Newtonian constitutive equation. Further 2D modeling at nonisothermal conditions shows that the choice of representative Newtonian viscosity is dependent on the amount of heating of the initially room temperature mold. An early 3D transient model shows that the initial design of the distributor is sub-optimal. However, these simulations take several months to run on 4 processors of an HP workstation using a preconditioner/solver combination of ILUT/GMRES with fill factors of 3 and PSPG stabilization. Therefore, several modifications to the distributor geometry and orientations of the vents and molds have been investigated using much faster 3D steady-state simulations. The pressure distribution for these steady-state calculations is examined for three different distributor designs to see if this can indicate which geometry has the superior design. The second modification, with a longer distributor, is shown to have flatter, more monotonic isobars perpendicular to the flow direction indicating a better filling process. The effects of the distributor modifications, as well as effects of the mold orientation, have also been examined with laboratory experiments in which the flow of a viscous Newtonian oil entering transparent molds is recorded visually. Here, the flow front is flatter and voids are reduced for the second geometry compared to the original geometry. A horizontal orientation, as opposed to the planned vertical orientation, results in fewer voids. Recently, the Navier-Stokes equations have been stabilized with the Dohrman-Bochev PSPP stabilization method, allowing us to calculate transient 3D simulations with computational times on the order of days instead of months. Validation simulations are performed and compared to the experiments. Many of the trends of the experiments are captured by the level set modeling, though quantitative agreement is lacking mainly due to the high value of the gas phase viscosity necessary for numerical stability, though physically unrealistic. More correct trends are predicted for the vertical model than the horizontal model, which is serendipitous as the actual mold is held in a vertical geometry. The full, transient mold filling calculations indicate that the flow front is flatter and voids may be reduced for the second geometry compared to the original geometry. The validated model is used to predict mold filling for the actual process with the material properties for the PZT paste, the original distributor geometry, and the mold in a vertical orientation. This calculation shows that voids may be trapped at the four corners of the mold opposite the distributor
Recommended from our members
Experiments for foam model development and validation.
A series of experiments has been performed to allow observation of the foaming process and the collection of temperature, rise rate, and microstructural data. Microfocus video is used in conjunction with particle image velocimetry (PIV) to elucidate the boundary condition at the wall. Rheology, reaction kinetics and density measurements complement the flow visualization. X-ray computed tomography (CT) is used to examine the cured foams to determine density gradients. These data provide input to a continuum level finite element model of the blowing process