514 research outputs found

    Innovative development of the inspired sinewave device to measure lung functions and inhomogeneity for diagnosis and evaluations of early lung diseases

    Get PDF
    Surprisingly, lung disease is still one of the leading causes of deaths in the developed countries, including UK. According to the UK National Health Service (NHS), Chronic Obstructive Pulmonary Disease (COPD) is the fifth biggest killer disease in the UK, killing approximately 25,000 people a year. This prob-lem is even worse in developing countries such as Vietnam, India and China, where air pollution is a big problem and the disease awareness is under-recognised. The NHS has set out one of its challenges is to identify people with lung disease earlier in the disease’s development pathway, in order to pro-vide more effective and timely intervention and treatment. This paper presents a novel Inspired Sinewave Device (ISD) to measure lung function and inhomogeneity. Both set of infor-mation are important for diagnosis and detection of early lung diseases. ISD has the potential to replace or supplement the traditional spirometry in the routine lung function testing. The paper describes both the principle of ISD and a set of experi-mental results demonstrating the capability of ISD to asymp-totically detect asthmatic symptoms. Finally the paper discuss-es the future plan, including the testing of 300+ COPD patients at the Oxford Respiratory Trials Unit in UK, and the potential collaborations among research institutions in Vietnam and UK about cost-effective and innovative developments of smart devices, biosensors, lab-on-chips and telehealth solutions for the routine lung function testing, diagnosis and evaluations of early lung diseases

    Investigating radiatively driven, magnetized plasmas with a university scale pulsed-power generator

    Get PDF
    We present first results from a novel experimental platform which is able to access physics relevant to topics including indirect-drive magnetised ICF; laser energy deposition; various topics in atomic physics; and laboratory astrophysics (for example the penetration of B-fields into HED plasmas). This platform uses the X-Rays from a wire array Z-Pinch to irradiate a silicon target, producing an outflow of ablated plasma. The ablated plasma expands into ambient, dynamically significant B-fields (~5 T) which are supported by the current flowing through the Z-Pinch. The outflows have a well-defined (quasi-1D) morphology, enabling the study of fundamental processes typically only available in more complex, integrated schemes. Experiments were fielded on the MAGPIE pulsed-power generator (1.4 MA, 240 ns rise time). On this machine a wire array Z-Pinch produces an X-Ray pulse carrying a total energy of ~15 kJ over ~30 ns. This equates to an average brightness temperature of around 10 eV on-target

    Acupuncture for chronic neck pain: a pilot for a randomised controlled trial

    Get PDF
    Background: Acupuncture is increasingly being used for many conditions including chronic neck pain. However the evidence remains inconclusive, indicating the need for further well-designed research. The aim of this study was to conduct a pilot randomised controlled parallel arm trial, to establish key features required for the design and implementation of a large-scale trial on acupuncture for chronic neck pain. Methods: Patients whose GPs had diagnosed neck pain were recruited from one general practice, and randomised to receive usual GP care only, or acupuncture ( up to 10 treatments over 3 months) as an adjunctive treatment to usual GP care. The primary outcome measure was the Northwick Park Neck Pain Questionnaire (NPQ) at 3 months. The primary analysis was to determine the sample size for the full scale study. Results: Of the 227 patients with neck pain identified from the GP database, 28 (12.3%) consenting patients were eligible to participate in the pilot and 24 (10.5%) were recruited to the trial. Ten patients were randomised to acupuncture, receiving an average of eight treatments from one of four acupuncturists, and 14 were randomised to usual GP care alone. The sample size for the full scale trial was calculated from a clinically meaningful difference of 5% on the NPQ and, from this pilot, an adjusted standard deviation of 15.3%. Assuming 90% power at the 5% significance level, a sample size of 229 would be required in each arm in a large-scale trial when allowing for a loss to follow-up rate of 14%. In order to achieve this sample, one would need to identify patients from databases of GP practices with a total population of 230,000 patients, or approximately 15 GP practices roughly equal in size to the one involved in this study (i.e. 15,694 patients). Conclusion: This pilot study has allowed a number of recommendations to be made to facilitate the design of a large-scale trial, which in turn will help to clarify the existing evidence base on acupuncture for neck pain

    A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

    Get PDF
    A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments

    Reliability of 1-repetition maximum estimation for upper and lower body muscular strength measurement in untrained middle aged type 2 diabetic patients

    Get PDF
    Purpose: The 1-repetition maximum (1-RM) test is the gold standard test for evaluating maximal dynamic strength of groups of muscles. However, safety of actual 1-RM testing is questionable in clinical situations such as type 2 diabetes (T2D), where an estimated 1-RM test is preferred. It is unclear if acceptable test retest reliability exists for the estimated 1-RM test in middle aged T2D patients. This study examined the reliability of the estimated 1-RM strength test in untrained middle aged T2D subjects.Methods: Twenty five untrained diabetic males (n=19) and females (n=6) aged 40.7+0.4 years participated in the study. Participants undertook the first estimated 1-RM test for five exercises namely supine bench press, leg press, lateral pull, leg extension and seated biceps curls. A familiarisation session was provided three to five days before the first test. 1-RM was estimated for all participants by Brzycki 1-RM prediction equation. Another identical 1-RM estimation procedure occurred one week after first test. Intraclass correlation coefficients (ICC), paired t-test, standard error of measurement (SEM), Bland-Altman plots, and estimation of 95% CI were used to assess reliability.Results: Test-retest reliability was excellent (ICC2,1=0.98-0.99) for all measurements with the highest for leg extension (ICC2,1=0.99). The SEM was lowest for lateral pull and leg extension exercises. Paired t-tests showed non-significant differences between the means of 2 sessions across three of five exercises.Conclusions: The study findings suggest that estimation of 1-RM is reliable for upper and lower body muscular strength measurement in untrained middle aged T2D patients.https://doi.org/10.5812/asjsm.345493pubpub

    The three-dimensional easy morphological (3-DEMO) classification of scoliosis, part II: repeatability

    Get PDF
    BACKGROUND: In the first part of this study we proposed a new classification approach for spinal deformities (3-DEMO). To be valid, a classification needs to overcome the repeatability issue which is inherent both in the used classificatory system and in the measured object. AIM: The aim of this study is to present procedures and results obtained within the repeatability of 3-DEMO classification for scoliosis analysis. METHOD: We acquired the data of 100 pathological and 20 normal spines with an optoelectronic system (AUSCAN) and of two dummies with simulated spine deformity. On the obtained 3D reconstruction of the spine, we considered the coronal view with a spinal reference system (Top View) and its three related parameters, defined in part I, constituting the 3-DEMO classification. We calculated the repeatability coefficient for the subjects (two acquisitions for each subject with a time interval of 26 ± 12 sec), whereas we evaluated the system measurement error calculating the standard deviation of 50 consecutive acquisitions for each dummy. RESULTS: Comparing the results of the two types of acquisition, it emerged that the main part of parameters variability was due to postural adjustments The proportion of agreement for the 3-DEMO parameters gives a k value above 0.8; almost 10% of patients changed classification because of postural adjustments, but none had a "mirror-like" variation nor a change in more of one parameter at a time Repeatability coefficient is lower than the previously calculated normative limits. DISCUSSION: The 3-DEMO classification has a high repeatability when evaluated with an optoelectronic system such as the AUSCAN System, whose systematic error is very low. This means that the implied physiological phenomenon is consistent and overcomes the postural variability inherent in the measured object (normal or pathological subject)

    Experiences, attitudes and barriers towards research amongst junior faculty of Pakistani medical universities

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The developing world has had limited quality research and in Pakistan, research is still in its infancy. We conducted a study to assess the proportion of junior faculty involved in research to highlight their attitude towards research, and identify the factors associated with their research involvement.</p> <p>Methods</p> <p>A cross-sectional study was conducted in four medical universities/teaching hospitals in Pakistan, representing private and public sectors. A pre-tested, self-administered questionnaire was used to collect information from 176 junior faculty members of studied universities/hospitals. Logistic regression analysis was used to identify factors related to attitudes and barriers in research among those currently involved in research with those who were not.</p> <p>Results</p> <p>Overall, 41.5% of study subjects were currently involved in research. A highly significant factor associated with current research involvement was research training during the post-graduate period (p < 0.001). Other factors associated with current involvement in research were male gender, working in the public sector and previous involvement in research. Overall, a large majority (85.2%) of doctors considered research helpful in their profession and had a positive attitude towards research; nevertheless this positive attitude was more frequently reported by doctors who were currently involved in research compared to those who were not (OR = 4.69; 95% CI = 1.54-14.26). Similarly, a large proportion (83.5%) of doctors considered research difficult to conduct; higher by doctors who were not presently involved in research (OR = 2.74; 95% CI = 1.20-6.22)</p> <p>Conclusion</p> <p>Less than half of the study participants were currently involved in research. Research output may improve if identified barriers are rectified. Further studies are recommended in this area.</p

    A prospective study of prognostic factors for duration of sick leave after endoscopic carpal tunnel release

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Endoscopic carpal tunnel release with a single portal technique has been shown to reduce sick leave compared to open carpal tunnel release, claiming to be a less invasive procedure and reducing scar tenderness leading to a more rapid return to work, and the purpose of this study was to identify prognostic factors for prolonged sick leave after endoscopic carpal tunnel release in a group of employed Danish patients.</p> <p>Methods</p> <p>The design was a prospective study including 75 employed patients with carpal tunnel syndrome operated with ECTR at two hospitals. The mean age was 46 years (SD 10.1), the male/female ratio was 0.42, and the mean preoperative duration of symptoms 10 months (range 6-12). Only 21 (28%) were unable to work preoperatively and mean sick leave was 4 weeks (range 1-4). At base-line and at the 3-month follow-up, a self-administered questionnaire was collected concerning physical, psychological, and social circumstances in relation to the hand problem. Data from a nerve conduction examination were collected at baseline and at the 3-month follow-up. Significant prognostic factors were identified through multiple logistic regression analysis.</p> <p>Results</p> <p>After the operation, the mean functional score was reduced from 2.3 to 1.4 (SD 0.8) and the mean symptom score from 2.9 to 1.5 (SD 0.7). The mean sick leave from work after the operation was 19.8 days (SD 14.3). Eighteen patients (24%) had more than 21 days of sick leave. Two patients (3%) were still unable to work after 3 months. Significant prognostic factors in the multivariate analysis for more than 21 days of postoperative sick leave were preoperative sick leave, blaming oneself for the hand problem and a preoperative distal motor latency.</p> <p>Conclusion</p> <p>Preoperative sick leave, blaming oneself for the hand problem, and a preoperative distal nerve conduction motor latency were prognostic factors for postoperative work absence of more than 21 days. Other factors may be important (clinical, demographic, economic, and workplace) in explaining the great variance in the results of sick leave after carpal tunnel release between studies from different countries.</p

    Controlling the corrosion and cathodic activation of magnesium via microalloying additions of Ge

    Get PDF
    The evolution of corrosion morphology and kinetics for magnesium (Mg) have been demonstrated to be influenced by cathodic activation, which implies that the rate of the cathodic partial reaction is enhanced as a result of anodic dissolution. This phenomenon was recently demonstrated to be moderated by the use of arsenic (As) alloying as a poison for the cathodic reaction, leading to significantly improved corrosion resistance. The pursuit of alternatives to toxic As is important as a means to imparting a technologically safe and effective corrosion control method for Mg (and its alloys). In this work, Mg was microalloyed with germanium (Ge), with the aim of improving corrosion resistance by retarding cathodic activation. Based on a combined analysis herein, we report that Ge is potent in supressing the cathodic hydrogen evolution reaction (reduction of water) upon Mg, improving corrosion resistance. With the addition of Ge, cathodic activation of Mg subject to cyclic polarisation was also hindered, with beneficial implications for future Mg electrodes

    The Galactic Center Black Hole Laboratory

    Full text link
    The super-massive 4 million solar mass black hole Sagittarius~A* (SgrA*) shows flare emission from the millimeter to the X-ray domain. A detailed analysis of the infrared light curves allows us to address the accretion phenomenon in a statistical way. The analysis shows that the near-infrared flare amplitudes are dominated by a single state power law, with the low states in SgrA* limited by confusion through the unresolved stellar background. There are several dusty objects in the immediate vicinity of SgrA*. The source G2/DSO is one of them. Its nature is unclear. It may be comparable to similar stellar dusty sources in the region or may consist predominantly of gas and dust. In this case a particularly enhanced accretion activity onto SgrA* may be expected in the near future. Here the interpretation of recent data and ongoing observations are discussed.Comment: 30 pages - 7 figures - accepted for publication by Springer's "Fundamental Theories of Physics" series; summarizing GC contributions of 2 conferences: 'Equations of Motion in Relativistic Gravity' at the Physikzentrum Bad Honnef, Bad Honnef, Germany, (Feb. 17-23, 2013) and the COST MP0905 'The Galactic Center Black Hole Laboratory' Granada, Spain (Nov. 19 - 22, 2013
    • …
    corecore