16 research outputs found

    A case study of an individual participant data meta-analysis of diagnostic accuracy showed that prediction regions represented heterogeneity well

    Get PDF
    The diagnostic accuracy of a screening tool is often characterized by its sensitivity and specificity. An analysis of these measures must consider their intrinsic correlation. In the context of an individual participant data meta-analysis, heterogeneity is one of the main components of the analysis. When using a random-effects meta-analytic model, prediction regions provide deeper insight into the effect of heterogeneity on the variability of estimated accuracy measures across the entire studied population, not just the average. This study aimed to investigate heterogeneity via prediction regions in an individual participant data meta-analysis of the sensitivity and specificity of the Patient Health Questionnaire-9 for screening to detect major depression. From the total number of studies in the pool, four dates were selected containing roughly 25%, 50%, 75% and 100% of the total number of participants. A bivariate random-effects model was fitted to studies up to and including each of these dates to jointly estimate sensitivity and specificity. Two-dimensional prediction regions were plotted in ROC-space. Subgroup analyses were carried out on sex and age, regardless of the date of the study. The dataset comprised 17,436 participants from 58 primary studies of which 2322 (13.3%) presented cases of major depression. Point estimates of sensitivity and specificity did not differ importantly as more studies were added to the model. However, correlation of the measures increased. As expected, standard errors of the logit pooled TPR and FPR consistently decreased as more studies were used, while standard deviations of the random-effects did not decrease monotonically. Subgroup analysis by sex did not reveal important contributions for observed heterogeneity; however, the shape of the prediction regions differed. Subgroup analysis by age did not reveal meaningful contributions to the heterogeneity and the prediction regions were similar in shape. Prediction intervals and regions reveal previously unseen trends in a dataset. In the context of a meta-analysis of diagnostic test accuracy, prediction regions can display the range of accuracy measures in different populations and settings

    Psychologische Betreuung von Brandverletzten

    No full text

    Reporting of conflicts of interest from drug trials in Cochrane reviews: cross sectional study

    No full text
    Objectives To investigate the degree to which Cochrane reviews of drug interventions published in 2010 reported conflicts of interest from included trials and, among reviews that reported this information, where it was located in the review documents. Design Cross sectional study. Data sources Cochrane Database of Systematic Reviews. Selection criteria Systematic reviews of drug interventions published in 2010 in the Cochrane Database of Systematic Reviews, with review content classified as up to date in 2008 or later and with results from one or more randomised controlled trials. Results Of 151 included Cochrane reviews, 46 (30%, 95% confidence interval 24% to 38%) reported information on the funding sources of included trials, including 30 (20%, 14% to 27%) that reported information on trial funding for all included trials and 16 (11%, 7% to 17%) that reported for some, but not all, trials. Only 16 of the 151 Cochrane reviews (11%, 7% to 17%) provided any information on trial author-industry financial ties or trial author-industry employment. Information on trial funding and trial author-industry ties was reported in one to seven locations within each review, with no consistent reporting location observed. Conclusions Most Cochrane reviews of drug trials published in 2010 did not provide information on trial funding sources or trial author-industry financial ties or employment. When this information was reported, location of reporting was inconsistent across reviews

    The Diagnostic Accuracy of the Patient Health Questionnaire-2 (PHQ-2) Patient Health Questionnaire-8 (PHQ-8) and Patient Health Questionnaire-9 (PHQ-9) for Detecting Major Depression: Protocol for a Systematic Review and Individual Patient Data Meta-analyses.

    No full text
    Background: Major depressive disorder (MDD) may be present in 10%-20% of patients in medical settings. Routine depression screening is sometimes recommended to improve depression management. However, studies of the diagnostic accuracy of depression screening tools have typically used data-driven, exploratory methods to select optimal cutoffs. Often, these studies report results from a small range of cutoff points around whatever cutoff score is most accurate in that given study. When published data are combined in meta-analyses, estimates of accuracy for different cutoff points may be based on data from different studies, rather than data from all studies for each possible cutoff point. As a result, traditional meta-analyses may generate exaggerated estimates of accuracy. Individual patient data (IPD) meta-analyses can address this problem by synthesizing data from all studies for each cutoff score to obtain diagnostic accuracy estimates. The nine-item Patient Health Questionnaire-9 (PHQ-9) and the shorter PHQ-2 and PHQ-8 are commonly recommended for depression screening. Thus, the primary objectives of our IPD meta-analyses are to determine the diagnostic accuracy of the PHQ-9, PHQ-8, and PHQ-2 to detect MDD among adults across all potentially relevant cutoff scores. Secondary analyses involve assessing accuracy accounting for patient factors that may influence accuracy (age, sex, medical comorbidity). Methods/Design: Data sources will include MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, PsycINFO, and Web of Science. We will include studies that included a Diagnostic and Statistical Manual or International Classification of Diseases diagnosis of MDD based on a validated structured or semi-structured clinical interview administered within 2 weeks of the administration of the PHQ. Two reviewers will independently screen titles and abstracts, perform full article review, and extract study data. Disagreements will be resolved by consensus. Risk of bias will be assessed with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Bivariate random-effects meta-analysis will be conducted for the full range of plausible cutoff values. Discussion: The proposed IPD meta-analyses will allow us to obtain estimates of the diagnostic accuracy of the PHQ-9, PHQ-8, and PHQ-2

    Diagnostic accuracy of the edinburgh postnatal depression scale (EPDS) for detecting major depression in pregnant and postnatal women: Protocol for a systematic review and individual patient data meta-analyses

    No full text
    Introduction: Studies of the diagnostic accuracy of depression screening tools often used data-driven methods to select optimal cut-offs. Typically, these studies report results from a small range of cut-off points around whatever cut-off score is identified as most accurate. When published data are combined in meta-analyses, estimates of accuracy for different cutoff points may be based on data from different studies, rather than data from all studies for each cut-off point. Thus, traditional meta-analyses may exaggerate accuracy estimates. Individual patient data (IPD) metaanalyses synthesise data from all studies for each cutoff score to obtain accuracy estimates. The 10-item Edinburgh Postnatal Depression Scale (EPDS) is commonly recommended for depression screening in the perinatal period. The primary objective of this IPD meta-analysis is to determine the diagnostic accuracy of the EPDS to detect major depression among women during pregnancy and in the postpartum period across all potentially relevant cut-off scores, accounting for patient factors that may influence accuracy (age, pregnancy vs postpartum). Methods and analysis: Data sources will include Medline, Medline In-Process & Other Non-Indexed Citations, PsycINFO, and Web of Science. Studies that include a diagnosis of major depression based on a validated structured or semistructured clinical interview administered within 2 weeks of (before or after) the administration of the EPDS will be included. Risk of bias will be assessed with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Bivariate randomeffects meta-analysis will be conducted for the full range of plausible cut-off values. Analyses will evaluate data from pregnancy and the postpartum period separately, as well as combining data from all women in a single model

    Equivalency of the diagnostic accuracy of the PHQ-8 and PHQ-9: A systematic review and individual participant data meta-analysis

    No full text
    Item 9 of the Patient Health Questionnaire-9 (PHQ-9) queries about thoughts of death and self-harm, but not suicidality. Although it is sometimes used to assess suicide risk, most positive responses are not associated with suicidality. The PHQ-8, which omits Item 9, is thus increasingly used in research. We assessed equivalency of total score correlations and the diagnostic accuracy to detect major depression of the PHQ-8 and PHQ-9.Methods We conducted an individual patient data meta-analysis. We fit bivariate random-effects models to assess diagnostic accuracy.Results 16 742 participants (2097 major depression cases) from 54 studies were included. The correlation between PHQ-8 and PHQ-9 scores was 0.996 (95 confidence interval 0.996 to 0.996). The standard cutoff score of 10 for the PHQ-9 maximized sensitivity + specificity for the PHQ-8 among studies that used a semi-structured diagnostic interview reference standard (N = 27). At cutoff 10, the PHQ-8 was less sensitive by 0.02 (-0.06 to 0.00) and more specific by 0.01 (0.00 to 0.01) among those studies (N = 27), with similar results for studies that used other types of interviews (N = 27). For all 54 primary studies combined, across all cutoffs, the PHQ-8 was less sensitive than the PHQ-9 by 0.00 to 0.05 (0.03 at cutoff 10), and specificity was within 0.01 for all cutoffs (0.00 to 0.01).Conclusions PHQ-8 and PHQ-9 total scores were similar. Sensitivity may be minimally reduced with the PHQ-8, but specificity is similar. Copyright © Cambridge University Press 2019
    corecore