9,592 research outputs found
Thermogravimetric instrument
Thermogravimetric instrument to measure volatility under both isothermal and nonisothermal conditions and to study thermal decompositio
A filter spectrometer concept for facsimile cameras
A concept which utilizes interference filters and photodetector arrays to integrate spectrometry with the basic imagery function of a facsimile camera is described and analyzed. The analysis considers spectral resolution, instantaneous field of view, spectral range, and signal-to-noise ratio. Specific performance predictions for the Martian environment, the Viking facsimile camera design parameters, and a signal-to-noise ratio for each spectral band equal to or greater than 256 indicate the feasibility of obtaining a spectral resolution of 0.01 micrometers with an instantaneous field of view of about 0.1 deg in the 0.425 micrometers to 1.025 micrometers range using silicon photodetectors. A spectral resolution of 0.05 micrometers with an instantaneous field of view of about 0.6 deg in the 1.0 to 2.7 micrometers range using lead sulfide photodetectors is also feasible
Southwest Research Institute assistance to NASA in biomedical areas of the technology utilization program Quarterly progress report, 1 May - 31 Jul. 1969
Dissemination of NASA derived technologies for biomedical applicatio
A reliable Pade analytical continuation method based on a high accuracy symbolic computation algorithm
We critique a Pade analytic continuation method whereby a rational polynomial
function is fit to a set of input points by means of a single matrix inversion.
This procedure is accomplished to an extremely high accuracy using a novel
symbolic computation algorithm. As an example of this method in action we apply
it to the problem of determining the spectral function of a one-particle
thermal Green's function known only at a finite number of Matsubara frequencies
with two example self energies drawn from the T-matrix theory of the Hubbard
model. We present a systematic analysis of the effects of error in the input
points on the analytic continuation, and this leads us to propose a procedure
to test quantitatively the reliability of the resulting continuation, thus
eliminating the black magic label frequently attached to this procedure.Comment: 11 pages, 8 eps figs, revtex format; revised version includes
reference to anonymous ftp site containing example codes (MapleVr5.1
worksheets) displaying the implementation of the algorithm, including the
padematinv.m library packag
Effectiveness of slow motion video compared to real time video in improving the accuracy and consistency of subjective gait analysis in dogs
Objective measures of canine gait quality via force plates, pressure mats or kinematic analysis are considered superior to subjective gait assessment (SGA). Despite research demonstrating that SGA does not accurately detect subtle lameness, it remains the most commonly performed diagnostic test for detecting lameness in dogs. This is largely because the financial, temporal and spatial requirements for existing objective gait analysis equipment makes this technology impractical for
use in general practice. The utility of slow motion video as a potential tool to augment SGA is currently untested. To evaluate a more accessible way to overcome the limitations of SGA, a slow motion video study was undertaken. Three experienced veterinarians reviewed video footage of 30 dogs, 15 with a diagnosis of primary limb lameness based on history and physical examination, and 15 with no indication of limb lameness based on history and physical examination. Four different videos were made for each dog, demonstrating each dog walking and trotting in real time, and then again walking and trotting in 50% slow motion. For each video, the veterinary raters assessed both the degree of lameness, and which limb(s) they felt represented the source of the lameness. Spearman’s rho, Cramer’s V, and t-tests were performed to determine if slow motion video increased either the accuracy or consistency of raters’ SGA relative to real time video. Raters demonstrated no significant increase in consistency or accuracy in their SGA of slow motion video relative to real time video. Based on these findings, slow motion video does not increase the consistency or accuracy of SGA values. Further research is required to determine if slow motion video will benefit SGA in other ways
- …