515 research outputs found

    Neutron sources based on medical Linac

    Get PDF
    The paper proposes the study of a novel photo-neutron source based on a medical high-energy electron Linac. Previous studies by the authors already demonstrated the possibility to obtain with this technique a thermal neutron flux of the order of 107 cm−2 s−1. This paper shows possible Linac’s setup and a new photo-converter design to reach a thermal neutron flux around 6 × 107 cm−2 s−1, keeping a reasonable high quality of the beam with respect to fast neutron and gamma contaminations

    Analysis and tests of TF magnet insulation samples for the JET upgrade to 4 tesla

    Get PDF
    The JET Toroidal Field (TF) coils were originally designed for operation at 3.4 tesla. In order to upgrade the field to 4 tesla and thus improve the performance of the JET machine, new mechanical tests and analysis were carried out on the insulation of TF coil samples. They are aimed at investigating the mechanical properties and the status of the insulation in order to set allowable stresses and force limits. In particular since the shear stress in the insulation is strongly affected by the shear modulus of elasticity G, it is important to measure this parameter. A method for the measurement of G in glass-resin fibres, the V-notched beam method (Iosipescu method) , was applied. The particular shape of the rectangular Iosipescu V- notched sample and the particular modality of force application produce pure shear stress for a reliable measurement of the G value and of the shear strength of the insulation. The effect of temperature on these mechanical properties was also investigated. Results show higher average shear strength with lower scatter compared with previous tests on conventional rectangular samples, thus confirming the reliability of the method. Micrographic analysis of the insulation and comparison between the straight and curved regions of the magnet, where the highest stress occurs, confirm the good quality of the impregnation of the coil. Glass-resin content, void content, micros and TG measurements have been performed on different samples and correlation between the different properties of the insulation investigated. Moreover fatigue tests at different temperatures were performed and data analyzed with the cumulative damage technique, which allows for an extrapolation of the fatigue curve with less samples than the standard method. (6 refs)

    First results with the {ANET} Compact Thermal Neutron Collimator

    Get PDF
    This paper presents the first determination of the spatial resolution of the ANET Compact Neutron Collimator, obtained with a measuring campaign at the LENA Mark-II TRIGA reactor in Pavia. This novel collimator consists of a sequence of collimating and absorbing channels organised in a chessboard-like geometry. It has a scalable structure both in length and in the field of view. It is characterized by an elevated collimation power within a limited length. Its scalability and compactness are added values with respect to traditional collimating system. The prototype tested in this article is composed of 4 concatenated stages, each 100mm long, with a channel width of 2.5mm, delivering a nominal L/D factor of 160. This measuring campaign illustrates the use of the ANET collimator and its potential application in neutron imaging for facilities with small or medium size neutron sources.Comment: 9 pages, 8 figures, prepared for submission to JINS

    Effect of pulmonary rehabilitation on heart rate recovery in adult individuals with asthma or chronic obstructive pulmonary disease

    Get PDF
    Introduction: Heart rate recovery (HRR) after exercise is a marker of disease severity and prognosis in cardiovascular and respiratory disorders. More than 30% of adult individuals with asthma may show a slow HRR. Pulmonary rehabilitation improves exercise capacity in individuals with asthma or chronic obstructive pulmonary disease (COPD). Aim: The study aimed to evaluate the effect of pulmonary rehabilitation on HRR in individuals with asthma as compared to those with COPD. Methods: Retrospective analysis of HRR one minute after the six-minute walking test (6MWT) was performed before and after an exercise training program. The COPD Assessment Test (CAT), Barthel Index-Dyspnea (BI-D), Medical Research Council (MRC) score for dyspnea, and the Five-Times-Sit-to-Stand test (5STS) were also assessed as secondary outcome measures. Results: Slow HRR prevalence was significantly lower in individuals with asthma than with COPD (29.1 vs. 46.7%, respectively: p = 0.003). Post-program HRR did not change in more than 70% of individuals in either population and improved in 16% of both populations, whereas it actually worsened in 12 and 10% of individuals with asthma and COPD, respectively. The outcome measures significantly improved in both populations, irrespective of baseline HRR. Conclusion: In individuals with asthma or COPD, exercise training does not significantly improve HRR

    "Thermoluminescence dating laboratory improvements tested on an archaeological rescue site in Trino, Vercelli province, Italy"

    Get PDF
    Thermoluminescence (TL) is a reliable radiation-based technique for the dating and authentication of ceramic objects, allowing the evaluation of the time elapsed since their last exposure to high temperatures (e.g. firing in kiln or later fire events). The TL laboratory developed in the last decade at the Physics Department of the University of Torino, currently operating within the INFN (National Institute of Nuclear Physics) CHNet network, is presented. The 10-years-long experience in the field resulted in the enhancement of the procedures, with the development of customised α and β irradiation systems and the optimisation of sampling approach and chemical pre-treatment. In collaboration with TecnArt S.r.l., the improved procedures were employed for dating two structures from a rescue archaeological site in the Vercelli province (Italy)

    X-ray grating interferometry design for the 4D GRAPH-X system

    Get PDF
    The 4D GRAPH-X (Dynamic GRAting-based PHase contrast x-ray imaging) project aims at developing a prototype of an x-ray grating-based phase-contrast imaging scanner in a laboratory setting, which is based on the Moire single-shot acquisition method in order to be optimized for analysing moving objects (in the specific case, a dynamic thorax phantom), that could evolve into a suitable tool for biomedical applications although it can be extended to other application fields. When designing an x-ray Talbot-Lau interferometer, high visibility and sensitivity are two important figures of merit, strictly related to the performance of the system in obtaining high quality phase contrast and dark-field images. Wave field simulations are performed to optimize the setup specifications and construct a high-resolution and high-sensitivity imaging system. In this work, the design of a dynamic imaging setup using a conventional milli-focus x-ray source is presented. Optimization by wave front simulations leads to a symmetric configuration with 5.25 mu m pitch at third Talbot order and 45 keV design energy. The simulated visibility is about 22%. Results from GATE based Monte Carlo simulations show a 19% transmission percentage of the incoming beam into the detector after passing through all the gratings and the sample. Such results are promising in view of building a system optimized for dynamic imaging
    • …
    corecore