339 research outputs found

    Local multi-channel RF surface coil versus body RF coil transmission for cardiac magnetic resonance at 3 Tesla: which configuration is winning the game?

    Get PDF
    INTRODUCTION: The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. METHODS: Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each transmission regime flip angle distributions and blood-myocardium contrast are examined in a volunteer study of 12 subjects. The feasibility of the local transceiver RF coil array for cardiac chamber quantification at 3 Tesla is demonstrated. RESULTS: Our simulations and experiments demonstrate that cardiac MR at 3 Tesla using four-channel surface RF coil transmission is competitive versus current clinical CMR practice of large volume body RF coil transmission. The efficiency advantage of the 4TX/4RX setup facilitates shorter repetition times governed by local SAR limits versus body RF coil transmission at whole-body SAR limit. No statistically significant difference was found for cardiac chamber quantification derived with body RF coil versus four-channel surface RF coil transmission. Our simulation also show that the body RF coil exceeds local SAR limits by a factor of ~2 when driven at maximum applicable input power to reach the whole-body SAR limit. CONCLUSION: Pursuing local surface RF coil arrays for transmission in cardiac MR is a conceptually appealing alternative to body RF coil transmission, especially for patients with implants

    Changes in inferior vena cava area represent a more sensitive metric than changes in filling pressures during experimental manipulation of intravascular volume and tone

    Get PDF
    AIMS: Remote monitoring of pulmonary artery pressure has reduced heart failure (HF) hospitalizations in chronic HF as elevation of pulmonary artery pressure provides information that can guide treatment. The venous system is characterized by high capacitance, thus substantial increases in intravascular volume can occur before filling pressures increase. The inferior vena cava (IVC) is a highly compliant venous conduit and thus a candidate for early detection of change in intravascular volume. We aimed to compare IVC cross-sectional area using a novel sensor with cardiac filling pressures during experimental manipulation of volume status, vascular tone, and cardiac function. METHODS AND RESULTS: Experiments were conducted in sheep to manipulate volume status (colloid infusion), vascular tone (nitroglycerin infusion) and cardiac function (rapid cardiac pacing). A wireless implantable IVC sensor was validated ex-vivo and in-vivo, and then used to measure the cross-sectional area of the IVC. Right- and left-sided cardiac filling pressures were obtained via right heart catheterization. The IVC sensor provided highly accurate and precise measurements of cross-sectional area in ex-vivo and in-vivo validation. IVC area changes were more sensitive than the corresponding changes in cardiac filling pressures during colloid infusion (p < 0.001), vasodilatation (p < 0.001) and cardiac dysfunction induced by rapid pacing (p ≤ 0.02). CONCLUSIONS: Inferior vena cava area can be remotely and accurately measured in real time with a wireless implantable sensor. Changes in IVC area are more sensitive than corresponding changes in filling pressures following experimental volume loading and fluid redistribution. Additional research is warranted to understand if remote monitoring of the IVC may have advantages over pressure-based monitors in HF

    Measurement of the partial widths of the Z into up- and down-type quarks

    Full text link
    Using the entire OPAL LEP1 on-peak Z hadronic decay sample, Z -> qbarq gamma decays were selected by tagging hadronic final states with isolated photon candidates in the electromagnetic calorimeter. Combining the measured rates of Z -> qbarq gamma decays with the total rate of hadronic Z decays permits the simultaneous determination of the widths of the Z into up- and down-type quarks. The values obtained, with total errors, were Gamma u = 300 ^{+19}_{-18} MeV and Gamma d = 381 ^{+12}_{-12} MeV. The results are in good agreement with the Standard Model expectation.Comment: 22 pages, 5 figures, Submitted to Phys. Letts.

    Tests of model of color reconnection and a search for glueballs using gluon jets with a rapidity gap

    Full text link
    Gluon jets with a mean energy of 22 GeV and purity of 95% are selected from hadronic Z0 decay events produced in e+e- annihilations. A subsample of these jets is identified which exhibits a large gap in the rapidity distribution of particles within the jet. After imposing the requirement of a rapidity gap, the gluon jet purity is 86%. These jets are observed to demonstrate a high degree of sensitivity to the presence of color reconnection, i.e. higher order QCD processes affecting the underlying color structure. We use our data to test three QCD models which include a simulation of color reconnection: one in the Ariadne Monte Carlo, one in the Herwig Monte Carlo, and the other by Rathsman in the Pythia Monte Carlo. We find the Rathsman and Ariadne color reconnection models can describe our gluon jet measurements only if very large values are used for the cutoff parameters which serve to terminate the parton showers, and that the description of inclusive Z0 data is significantly degraded in this case. We conclude that color reconnection as implemented by these two models is disfavored. The signal from the Herwig color reconnection model is less clear and we do not obtain a definite conclusion concerning this model. In a separate study, we follow recent theoretical suggestions and search for glueball-like objects in the leading part of the gluon jets. No clear evidence is observed for these objects.Comment: 42 pages, 18 figure

    Search for R-Parity Violating Decays of Scalar Fermions at LEP

    Full text link
    A search for pair-produced scalar fermions under the assumption that R-parity is not conserved has been performed using data collected with the OPAL detector at LEP. The data samples analysed correspond to an integrated luminosity of about 610 pb-1 collected at centre-of-mass energies of sqrt(s) 189-209 GeV. An important consequence of R-parity violation is that the lightest supersymmetric particle is expected to be unstable. Searches of R-parity violating decays of charged sleptons, sneutrinos and squarks have been performed under the assumptions that the lightest supersymmetric particle decays promptly and that only one of the R-parity violating couplings is dominant for each of the decay modes considered. Such processes would yield final states consisting of leptons, jets, or both with or without missing energy. No significant single-like excess of events has been observed with respect to the Standard Model expectations. Limits on the production cross- section of scalar fermions in R-parity violating scenarios are obtained. Constraints on the supersymmetric particle masses are also presented in an R-parity violating framework analogous to the Constrained Minimal Supersymmetric Standard Model.Comment: 51 pages, 24 figures, Submitted to Eur. Phys. J.

    Search for the standard model Higgs boson at LEP

    Get PDF

    Urinary Ethyl Glucuronide Can Be Used as a Biomarker of Habitual Alcohol Consumption in the General Population

    Get PDF
    BACKGROUND: Alcohol consumption is a frequently studied risk factor for chronic diseases, but many studies are hampered by self-report of alcohol consumption. The urinary metabolite ethyl glucuronide (EtG), reflecting alcohol consumption during the past 72 h, is a promising objective marker, but population data are lacking. OBJECTIVE: The objective of this study was to assess the reliability of EtG as a marker for habitual alcohol consumption compared with self-report and other biomarkers in the general population. METHODS: Among 6211 participants in the Prevention of Renal and Vascular End-Stage Disease (PREVEND) cohort, EtG concentrations were measured in 24-h urine samples. EtG was considered positive when concentrations were ≥100 ng/mL. Habitual alcohol consumption was self-reported by questionnaire (categories: no/almost never, 1-4 units per month, 2-7 units per week, 1-3 units per day or ≥4 units per day). Plasma HDL cholesterol concentration, erythrocyte mean corpuscular volume (MCV), aspartate aminotransferase (AST), alanine aminotransferase (ALT), and γ-glutamyltransferase (GGT) were determined as indirect biomarkers of alcohol consumption. Sensitivity, specificity, positive and negative predictive value, and proportions of agreement between reported consumption and EtG were calculated. To test the agreement of EtG concentration and alcohol consumption in categories, linear regression analysis was performed. In addition, the association between EtG concentrations and indirect biomarkers was analyzed. RESULTS: Mean age was 53.7 y, and 52.9% of participants men. Of the self-reported abstainers, 92.3% had an EtG concentration <100 ng/mL. Sensitivity was 66.3%, positive predictive value was 96.3%, and negative predictive value was 47.4%. The proportion of positive agreement was 78.5%, and the proportion of negative agreement was 62.7%. EtG concentrations were linearly associated with higher categories of alcohol consumption (P-trend < 0.001), adjusted for age, sex, and renal function. EtG was positively related to MCV, HDL cholesterol, and GGT but not to AST and ALT concentrations. CONCLUSIONS: This study shows that urinary EtG is in reasonable agreement with self-reported alcohol consumption and therefore can be used as an objective marker of habitual alcohol consumption in the general population

    Search for the Standard Model Higgs Boson with the OPAL Detector at LEP

    Full text link
    This paper summarises the search for the Standard Model Higgs boson in e+e- collisions at centre-of-mass energies up to 209 GeV performed by the OPAL Collaboration at LEP. The consistency of the data with the background hypothesis and various Higgs boson mass hypotheses is examined. No indication of a signal is found in the data and a lower bound of 112.7GeV/C^2 is obtained on the mass of the Standard Model Higgs boson at the 95% CL.Comment: 51 pages, 21 figure

    A study of charm production in beauty decays with the OPAL detector at LEP

    Full text link
    Using an inclusive method, BR(b -> D\bar{D}X) has been measured in hadronic Z^0 decays with the OPAL detector at LEP. The impact parameter significance of tracks opposite tagged b-jets is used to differentiate b -> D\bar{D}X decays from other decays. Using this result, the average number of charm and anti-charm quarks produced per beauty quark decay, n_c, is determined.Comment: 20 pages, 4 figure

    Measurement of triple gauge boson couplings from WW production at LEP energies up to 189 GeV

    Get PDF
    A measurement of triple gauge boson couplings is presented, based on W-pair data recorded by the OPAL detector at LEP during 1998 at a centre-of-mass energy of 189 GeV with an integrated luminosity of 183 pb^-1. After combining with our previous measurements at centre-of-mass energies of 161-183 GeV we obtain k_g=0.97 +0.20 -0.16, g_1^z=0.991 +0.060 -0.057 and lambda_g=-0.110 +0.058 -0.055, where the errors include both statistical and systematic uncertainties and each coupling is determined by setting the other two couplings to their SM values. These results are consistent with the Standard Model expectations.Comment: 28 pages, 8 figures, submitted to Eur. Phys. J.
    • …
    corecore