87 research outputs found

    Diagnostic Workup for Patients with Solid Renal Masses: A Cost-Effectiveness Analysis

    Get PDF
    Simple Summary There are several benign and malignant types of solid renal masses. For diagnostic and characterization of these masses, a few imaging methods such as magnetic resonance imaging (MRI), computed tomography (CT) or (contrast-enhanced) ultrasound (CEUS) are established in the clinical routine. The aim of our study was to assess the most economical approach for detecting and characterizing these masses. As a result, contrast-enhanced ultrasound turned out to be a cost-effective diagnostic method. Therefore, if available, this method should be considered in the routine. Alternatively, MRI also offers excellent diagnostic accuracy, but it is associated with higher costs. This result may lead to a change in the diagnostic workup of solid renal masses in clinical routine, as contrast-enhanced ultrasound should be considered as an appropriate method for the first analysis compared to CT and MRI. Background: For patients with solid renal masses, a precise differentiation between malignant and benign tumors is crucial for forward treatment management. Even though MRI and CT are often deemed as the gold standard in the diagnosis of solid renal masses, CEUS may also offer very high sensitivity in detection. The aim of this study therefore was to evaluate the effectiveness of CEUS from an economical point of view. Methods: A decision-making model based on a Markov model assessed expenses and utilities (in QALYs) associated with CEUS, MRI and CT. The utilized parameters were acquired from published research. Further, a Monte Carlo simulation-based deterministic sensitivity analysis of utilized variables with 30,000 repetitions was executed. The willingness-to-pay (WTP) is at USD 100,000/QALY. Results: In the baseline, CT caused overall expenses of USD 10,285.58 and an efficacy of 11.95 QALYs, whereas MRI caused overall expenses of USD 7407.70 and an efficacy of 12.25. Further, CEUS caused overall expenses of USD 5539.78, with an efficacy of 12.44. Consequently, CT and MRI were dominated by CEUS, and CEUS remained cost-effective in the sensitivity analyses. Conclusions: CEUS should be considered as a cost-effective imaging strategy for the initial diagnostic workup and assessment of solid renal masses compared to CT and MRI

    Five-Year Follow-Up of a Slowly Resorbable Biosynthetic P4HB Mesh (Phasix) in VHWG Grade 3 Incisional Hernia Repair

    Get PDF
    OBJECTIVE: To assess the 5-year recurrence rate of incisional hernia repair in Ventral Hernia Working Group (VHWG) 3 hernia with a slowly resorbable mesh.SUMMARY BACKGROUND DATA: Incisional hernia recurs frequently after initial repair. In potentially contaminated hernia, recurrences rise to 40%. Recently, the biosynthetic Phasix mesh has been developed that is resorbed in 12-18 months. Resorbable meshes might be a solution for incisional hernia repair to decrease short- and long-term (mesh) complications. However, long-term outcomes after resorption are scarce.METHODS: Patients with VHWG grade 3 incisional midline hernia, who participated in the Phasix trial (Clinilcaltrials.gov: NCT02720042) were included by means of physical examination and computed tomography (CT). Primary outcome was hernia recurrence; secondary outcomes comprised of long-term mesh complications, reoperations, and abdominal wall pain [visual analogue score (VAS): 0-10].RESULTS: In total, 61/84 (72.6%) patients were seen. Median follow-up time was 60.0 [interquartile range (IQR): 55-64] months. CT scan was made in 39 patients (68.4%). A recurrence rate of 15.9% (95% confidence interval: 6.9-24.8) was calculated after 5 years. Four new recurrences (6.6%) were found between 2 and 5 years. Two were asymptomatic. In total, 13/84 recurrences were found. No long-term mesh complications and/or interventions occurred. VAS scores were 0 (IQR: 0-2).CONCLUSIONS: Hernia repair with Phasix mesh in high-risk patients (VHWG 3, body mass index &gt;28) demonstrated a recurrence rate of 15.9%, low pain scores, no mesh-related complications or reoperations for chronic pain between the 2- and 5-year follow-up. Four new recurrences occurred, 2 were asymptomatic. The poly-4-hydroxybutyrate mesh is a safe mesh for hernia repair in VHWG 3 patients, which avoids long-term mesh complications like pain and mesh infection.</p

    Outcomes of a new slowly resorbable biosynthetic mesh (Phasix (TM)) in potentially contaminated incisional hernias : a prospective, multi-center, single-arm trial

    Get PDF
    Background: Resorbable biomaterials have been developed to reduce the amount of foreign material remaining in the body after hernia repair over the long-term. However, on the short-term, these resorbable materials should render acceptable results with regard to complications, infections, and reoperations to be considered for repair. Additionally, the rate of resorption should not be any faster than collagen deposition and maturation; leading to early hernia recurrence. Therefore, the objective of this study was to collect data on the short-term performance of a new resorbable biosynthetic mesh (Phasix (TM)) in patients requiring Ventral Hernia Working Group (VHWG) Grade 3 midline incisional hernia repair. Materials and methods: A prospective, multi-center, single-arm trial was conducted at surgical departments in 15 hospitals across Europe. Patients aged >= 18, scheduled to undergo elective Ventral Hernia Working Group Grade 3 hernia repair of a hernia larger than 10 cm(2) were included. Hernia repair was performed with Phasix (TM) Mesh in sublay position when achievable. The primary outcome was the rate of surgical site occurrence (SSO), including infections, that required intervention until 3 months after repair. Results: In total, 84 patients were treated with Phasix (TM) Mesh. Twenty-two patients (26.2%) developed 32 surgical site occurrences. These included 11 surgical site infections, 9 wound dehiscences, 7 seromas, 2 hematomas, 2 skin necroses, and 1 fistula. No significant differences in surgical site occurrence development were found between groups repaired with or without component separation technique, and between clean-contaminated or contaminated wound sites. At three months, there were no hernia recurrences. Conclusion: Phasix (TM) Mesh demonstrated acceptable postoperative surgical site occurrence rates in patients with a Ventral Hernia Working Group Grade 3 hernia. Longer follow-up is needed to evaluate the recurrence rate and the effects on quality of life. This study is ongoing through 24 months of follow-up

    A post-market, prospective, multi-center, single-arm clinical investigation of Phasixâ„¢ mesh for VHWG grade 3 midline incisional hernia repair

    Get PDF
    BACKGROUND: Incisional heia is a frequent complication of midline laparotomy. The use of mesh in hernia repair has been reported to lead to fewer recurrences compared to primary repair. However, in Ventral Hernia Working Group (VHWG) Grade 3 hernia patients, whose hernia is potentially contaminated, synthetic mesh is prone to infection. There is a strong preference for resorbable biological mesh in contaminated fields, since it is more able to resist infection, and because it is fully resorbed, the chance of a foreign body reaction is reduced. However, when not crosslinked, biological resorbable mesh products tend to degrade too quickly to facilitate native cellular ingrowth. Phasix™ Mesh is a biosynthetic mesh with both the biocompatibility and resorbability of a biological mesh and the mechanical strength of a synthetic mesh. This multi-center single-arm study aims to collect data on safety and performance of Phasix™ Mesh in Grade 3 hernia patients. METHODS: A total of 85 VHWG Grade 3 hernia patients will be treated with Phasix™ Mesh in 15 sites across Europe. The primary outcome is Surgical Site Occurrence (SSO) including hematoma, seroma, infection, dehiscence and fistula formation (requiring intervention) through 3 months. Secondary outcomes include recurrence, infection and quality of life related outcomes after 24 months. Follow-up visits will be at drain removal (if drains were not placed, then on discharge or staple removal instead) and in the 1st, 3rd, 6th, 12th, 18th and 24th month after surgery. CONCLUSION: Based on evidence from this clinical study Depending on the results this clinical study will yield, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients. TRIAL REGISTRATION: The trial was registered on March 25, 2016 on clinicaltrials.gov: NCT02720042

    Does Market Liberalization Jeopardize Export Quality? Cameroonian Cocoa, 1995-2000

    No full text
    A frequently encountered argument against the liberalization of markets for tropical crop commodities is that this may jeopardize export quality. We look at this argument in the specific case of Cameroonian cocoa exports. The Cameroonian experience is important because an alleged decline in cocoa quality has often been cited as illustrating the dangers of market liberalization. That claim is not supported by examination of the unit value of cocoa imports into the European Union which demonstrates constant relativities over time in the unit value of cocoa imports from major west African producers. We argue that, in a liberalized environment, export quality is determined by the preferences of market participants and the technology of quality production. In Cameroon, changes in transport technology resulted in a diminished demand for premium grade cocoa while increased competition from cocoa buyers resulted in a transfer of some processing functions from farmers to intermediaries. There is no evidence of any significant quality problems arising from market liberalization. We conclude that government does not need to regulate in order to ensure a normal commercial outcome. Concerns about export quality should not be an issue in the continuing African market liberalization debate.cocoa; liberalization; quality

    Literatur

    No full text

    The forest-based farming system: highly diverse, annual and perennial systems under threat

    No full text
    Published online: 18 Dec 2019African forest-based farming systems (FBFS) are the starting point for most humid zone farming systems; they exist only at low population densities and, depending on population growth, are a relatively short transition phase into more sedentary systems with higher levels of specialization. FBFS provide a wide range of food and non-food products for many of which no alternative sources exist. FBFS farmers are highly food secure yet poorly connected to markets and service providers, thus severely cash-constrained and suffering from a lack of financial, medical, educational and social services rendering families vulnerable and cut off from urban employment opportunities. Due to low labour input FBFS achieve relatively low crop yields yet they are productive because of their often high soil fertility; they draw heavily on the natural resource base for relatively low outputs. FBFS are heavily threatened by land-grabbing attempts of large-scale investors. Policies need to address human welfare and conservation / environmental protection issues in parallel with providing technical support to FBFS farmers without leading to a rapid transition into more productive yet less sustainable farming systems. Intensification and modernization of FBFS have not received sufficient attention from research and policy makers, yet are a potential way to maintain forest environments combined with agricultural production
    • …
    corecore