1,217 research outputs found

    Channel-Optimized Quantum Error Correction

    Full text link
    We develop a theory for finding quantum error correction (QEC) procedures which are optimized for given noise channels. Our theory accounts for uncertainties in the noise channel, against which our QEC procedures are robust. We demonstrate via numerical examples that our optimized QEC procedures always achieve a higher channel fidelity than the standard error correction method, which is agnostic about the specifics of the channel. This demonstrates the importance of channel characterization before QEC procedures are applied. Our main novel finding is that in the setting of a known noise channel the recovery ancillas are redundant for optimized quantum error correction. We show this using a general rank minimization heuristic and supporting numerical calculations. Therefore, one can further improve the fidelity by utilizing all the available ancillas in the encoding block.Comment: 12 pages, 9 figure

    Hg-201 (+) CO-Magnetometer for HG-199(+) Trapped Ion Space Atomic Clocks

    Get PDF
    Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations

    A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks

    Get PDF
    A method has been developed for unambiguously measuring the exact magnetic field experienced by trapped mercury ions contained within an atomic clock intended for space applications. In general, atomic clocks are insensitive to external perturbations that would change the frequency at which the clocks operate. On a space platform, these perturbative effects can be much larger than they would be on the ground, especially in dealing with the magnetic field environment. The solution is to use a different isotope of mercury held within the same trap as the clock isotope. The magnetic field can be very accurately measured with a magnetic-field-sensitive atomic transition in the added isotope. Further, this measurement can be made simultaneously with normal clock operation, thereby not degrading clock performance. Instead of using a conventional magnetometer to measure ambient fields, which would necessarily be placed some distance away from the clock atoms, first order field-sensitive atomic transition frequency changes in the atoms themselves determine the variations in the magnetic field. As a result, all ambiguity over the exact field value experienced by the atoms is removed. Atoms used in atomic clocks always have an atomic transition (often referred to as the clock transition) that is sensitive to magnetic fields only in second order, and usually have one or more transitions that are first-order field sensitive. For operating parameters used in the (199)Hg(+) clock, the latter can be five orders of magnitude or more sensitive to field fluctuations than the clock transition, thereby providing an unambiguous probe of the magnetic field strength

    Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards

    Get PDF
    The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them

    Study on the growth parameters of Capoeta trutta (Heckel, 1843) in Shour River, Iran

    Get PDF
    In this study growth characteristics of 815 tuwini (Capoeta trutta) in Shour River were investigated during July 2010 through June 2011. The population was composed of 62.94% females and 32.02% males. Sex ratio was 1: 1.96, with significant differences observed at 1:1 (x^2= 150.6; df= 1; p<0.05). The age distribution of this population ranged from <1 to 6 years. The distribution of length and weight was between 95 and 300 mm. The average length, except in <1 year olds, was statistically significant between sexes and average weight in all age groups was statistically significant between sexes (p<0.05). Weight-length relationship was determined as W=0.0115L^2.9475 (R=0.91) in males and W=0.0096L^3.0025 (R= 0.88) in females. Von-Bertalanffy growth equation was Lt= 24.5(1-e^-0.333(t+2.54)) for males and Lt= 36.4 (1- e^-0.129(t+4.02)) for females. Growth performance index was also estimated as Φ=2.301 in males and Φ=2.223 in females

    Investigation of the double ramp in hypersonic flow using luminescent measurement systems

    Get PDF
    Compression ramp flows in supersonic and hypersonic environments present unique flow patterns for shock wave-boundary layer interaction studies. They also represent the generic geometry of two-dimensional inlets and deflected control surfaces for re-entry vehicles. Therefore, a detailed knowledge of the flow behaviour created by such geometries is critical for optimum design. The flow is made more complicated due to the presence of separation regions and streamwise Görtler vortices. The objective of the current research is to study the behaviour and characteristics of the flow over the double ramp model placed in hypersonic flow at freestream Mach number of 5. Three different incidence angles of 0°, −2°, and −4° are studied using colour Schlieren and luminescent paints consisting of anodized aluminium pressure-sensitive paint (AA-PSP) and the temperature-sensitive paint (TSP) technique. The colour Schlieren provides description of the external flow while the global surface pressure and temperature distribution is obtained through the AA-PSP and TSP methods. The TSP technique also proves that it is very effective in identifying the location and properties of the Görtler vortices; revealing the effect of incidence on the magnitude and pattern of Görtler vortices formed

    Cancer Screening in the Coronavirus Pandemic Era: Adjusting to a New Situation.

    Get PDF
    PURPOSE The coronavirus-induced pandemic has put great pressure on health systems worldwide. Nonemergency health services, such as cancer screening, have been scaled down or withheld as a result of travel restrictions and resources being redirected to manage the pandemic. The present article discusses the challenges to cancer screening implementation in the pandemic environment, suggesting ways to optimize services for breast, cervical, and colorectal cancer screening. METHODS The manuscript was drafted by a team of public health specialists with expertise in implementation and monitoring of cancer screening. A scoping review of literature revealed the lack of comprehensive guidance on continuation of cancer screening in the midst of waxing and waning of infection. The recommendations in the present article were based on the advisories issued by different health agencies and professional bodies and the authors' understanding of the best practices to maintain quality-assured cancer screening. RESULTS A well-coordinated approach is required to ensure that essential health services such as cancer management are maintained and elective services are not threatened, especially because of resource constraints. In the context of cancer screening, a few changes in invitation strategies, screening and management protocols and program governance need to be considered to fit into the new normal situation. Restoring public trust in providing efficient and safe services should be one of the key mandates for screening program reorganization. This may be a good opportunity to introduce innovations (eg, telehealth) and consider de-implementing non-evidence-based practices. It is necessary to consider increased spending on primary health care and incorporating screening services in basic health package. CONCLUSION The article provides guidance on reorganization of screening policies, governance, implementation, and program monitoring

    Forensic gender determination by using mandibular morphometric indices an Iranian population: a panoramic radiographic cross-sectional study

    Get PDF
    Gender determination is the first step in forensic identification, followed by age and height determination, which are both affected by gender. This study assessed the accuracy of gender estimation using mandibular morphometric indices on panoramic radiographs of an Iranian population. This retrospective study evaluated 290 panoramic radiographs (145 males and 145 females). The maximum and minimum ramus width, coronoid height, condylar height, antegonial angle, antegonial depth, gonial angle, and the superior border of mental foramen were bilaterally measured as well as bicondylar and bigonial breadths using Scanora Lite. Correlation of parameters with gender was analyzed by univariate, multiple, and best models. All indices except for gonial angle were significantly different between males and females and can be used for gender determination according to univariate model. Condylar height, coronoid height, and superior border of mental foramen and ramus were still significantly greater in males than in females after controlling for the effect of confounders (p &lt; 0.05). Based on the best model, a formula including five indices of bicondylar breadth, condylar height, coronoid height, minimum ramus width, and superior border of mental foramen was used for gender determination. Values higher than 56% indicate male gender, while lower values indicate female gender, with 81.38% specificity for correct detection of females and 88.97% sensitivity for correct detection of males. Despite the satisfactory results, future research should focus on larger populations to verify the accuracy of the present findings

    International recommendations for outpatient palliative care and prehospital palliative emergencies - a prospective questionnaire-based investigation

    Get PDF
    BACKGROUND: To determine the international recommendations and current practices for the treatment and prevention of palliative emergencies. The primary goal of the study was to gather information from experts on their nationally practised concepts. METHODS: One hundred and fifty self-report surveys were distributed by email to selected leading experts (palliative and emergency medical care) in Europe, North and South America, Africa, Asia, and Australia. An expert in this context was defined as an author of an article that was ranked by three reviewers as relevant to outpatient palliative and emergency medical . RESULTS: The total response rate was 61% (n = 92 experts). Survey responses were obtained from 35 different countries. The following standards in the treatment of palliative emergencies were recommended: (1) early integration of "Palliative Care Teams" (PCTs) and basic outpatient palliative care systems, (2) end-of-life discussions, (3) defined emergency medical documents, drug boxes, and "Do not attempt resuscitation" orders and (4) emergency medical training (physicians and paramedics). CONCLUSIONS: This study detected structurally and nationally differences in outpatient palliative care regarding the treatment of palliative emergencies. Accordingly, these differences should be discussed and adapted to the respective specifications of individual single countries. A single established outpatient palliative emergency medical care concept may be the basis for an overall out-of-hospital palliative care system
    • …
    corecore