58 research outputs found
Infrared optical properties of Pr2CuO4
The ab-plane reflectance of a Pr2CuO4 single crystal has been measured over a
wide frequency range at a variety of temperatures, and the optical properties
determined from a Kramers-Kronig analysis. Above ~ 250 K, the low frequency
conductivity increases quickly with temperature; the resistivity follows the
form e^(E_a/k_BT), where E_a ~ 0.17 eV is much less than the inferred optical
gap of ~ 1.2 eV. Transport measurements show that at low temperature the
resistivity deviates from activated behavior and follows the form
e^[(T_0/T)^1/4], indicating that the dc transport in this material is due to
variable-range hopping between localized states in the gap. The four
infrared-active Eu modes dominate the infrared optical properties. Below ~ 200
K, a striking new feature appears near the low-frequency Eu mode, and there is
additional new fine structure at high frequency. A normal coordinate analysis
has been performed and the detailed nature of the zone-center vibrations
determined. Only the low-frequency Eu mode has a significant Pr-Cu interaction.
Several possible mechanisms related to the antiferromagnetism in this material
are proposed to explain the sudden appearance of this and other new spectral
features at low temperature.Comment: 11 pages, 7 embedded EPS figures, REVTeX
Neuromuscular imaging in inherited muscle diseases
Driven by increasing numbers of newly identified genetic defects and new insights into the field of inherited muscle diseases, neuromuscular imaging in general and magnetic resonance imaging (MRI) in particular are increasingly being used to characterise the severity and pattern of muscle involvement. Although muscle biopsy is still the gold standard for the establishment of the definitive diagnosis, muscular imaging is an important diagnostic tool for the detection and quantification of dystrophic changes during the clinical workup of patients with hereditary muscle diseases. MRI is frequently used to describe muscle involvement patterns, which aids in narrowing of the differential diagnosis and distinguishing between dystrophic and non-dystrophic diseases. Recent work has demonstrated the usefulness of muscle imaging for the detection of specific congenital myopathies, mainly for the identification of the underlying genetic defect in core and centronuclear myopathies. Muscle imaging demonstrates characteristic patterns, which can be helpful for the differentiation of individual limb girdle muscular dystrophies. The aim of this review is to give a comprehensive overview of current methods and applications as well as future perspectives in the field of neuromuscular imaging in inherited muscle diseases. We also provide diagnostic algorithms that might guide us through the differential diagnosis in hereditary myopathies
Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods
Accelerated imaging is highly relevant for many CMR applications as competing constraints with respect to spatiotemporal resolution and tolerable scan times are frequently posed. Three approaches, all involving data undersampling to increase scan efficiencies, are discussed in this review. Zonal imaging can be considered a niche but nevertheless has found application in coronary imaging and CMR flow measurements. Current work on parallel-transmit systems is expected to revive the interest in zonal imaging techniques. The second and main approach to speeding up CMR sequences has been parallel imaging. A wide range of CMR applications has benefited from parallel imaging with reduction factors of two to three routinely applied for functional assessment, perfusion, viability and coronary imaging. Large coil arrays, as are becoming increasingly available, are expected to support reduction factors greater than three to four in particular in combination with 3D imaging protocols. Despite these prospects, theoretical work has indicated fundamental limits of coil encoding at clinically available magnetic field strengths. In that respect, alternative approaches exploiting prior knowledge about the object being imaged as such or jointly with parallel imaging have attracted considerable attention. Five to eight-fold scan accelerations in cine and dynamic CMR applications have been reported and image quality has been found to be favorable relative to using parallel imaging alone.
With all acceleration techniques, careful consideration of the limits and the trade-off between acceleration and occurrence of artifacts that may arise if these limits are breached is required. In parallel imaging the spatially varying noise has to be considered when measuring contrast- and signal-to-noise ratios. Also, temporal fidelity in images reconstructed with prior knowledge driven methods has to be studied carefully.ISSN:1097-6647ISSN:1532-429
MRI and CT in the diagnosis of coronary artery disease: indications and applications
In recent years, technical advances and improvements in cardiac computed tomography (CT) and cardiac magnetic resonance imaging (MRI) have provoked increasing interest in the potential clinical role of these techniques in the non-invasive work-up of patients with suspected coronary artery disease (CAD) and correct patient selection for these emerging imaging techniques. In the primary detection or exclusion of significant CAD, e.g. in the patient with unspecific thoracic complaints, and also in patients with known CAD or advanced stages of CAD, both CT and MRI yield specific advantages. In this review, the major aspects of non-invasive MR and CT imaging in the diagnosis of CAD will be discussed. The first part describes the clinical value of contrast-enhanced non-invasive CT coronary angiography (CTCA), including the diagnostic accuracy of CTCA for the exclusion or detection of significant CAD with coronary artery stenoses that may require angioplastic intervention, as well as potentially valuable information on the coronary artery vessel wall. In the second section, the potential of CT for the imaging of myocardial viability and perfusion will be highlighted. In the third and final part, the range of applications of cardiac MRI in CAD patients will be outlined
Protein secretion zones during overexpression of amylase within the Gram‑positive cell wall
Whereas the translocation of proteins across the cell membrane has been thoroughly investigated, it is still unclear how proteins cross the cell wall in Gram-positive bacteria, which are widely used for industrial applications. We have studied the secretion of α-amylase AmyE within two different Bacillus strains, B. subtilis and B. licheniformis.
We show that a C-terminal fusion of AmyE with the fluorescent reporter mCherry is secreted via discrete patches showing very low dynamics. These are visible at many places within the cell wall for many minutes. Expression from a high copy number plasmid was required to be able to see these structures we term “secretion zones”. Zones corresponded to visualized AmyE activity on the surface of cells, showing that they release active enzymes. They overlapped with SecA signals but did not frequently co-localize with the secretion ATPase. Single particle tracking showed higher dynamics of SecA and of SecDF, involved in AmyE secretion, at the cell membrane than AmyE. These experiments suggest that SecA initially translocates AmyE molecules through the cell membrane, and then diffuses to a different translocon. Single molecule tracking of SecA suggests the existence of three distinct diffusive states of SecA, which change during AmyE overexpression, but increased AmyE secretion does not appear to overwhelm the system.
Because secretion zones were only found during the transition to and within the stationary phase, diffusion rather than passive transport based on cell wall growth from inside to outside may release AmyE and, thus, probably secreted proteins in general. Our findings suggest active transport through the cell membrane and slow, passive transition through the cell wall, at least for overexpressed proteins, in bacteria of the genus Bacillus.Gefördert durch den Open-Access-Publikationsfonds der UB Marburg
Assembly of β-Cu2V2O7/WO3 heterostructured nanocomposites and the impact of their composition on structure and photoelectrochemical properties
Multinary metal oxides and their heterostructures play a key role as light absorbers in the production of solar chemicals. Synthetic tunability is crucial to understand the impact of composition and structure on the photoelectrochemical performance. Here, we assemble \u3b2-Cu2V2O7/WO3 heterostructured nanocomposites using a novel seeded-growth approach which allows an unprecedented compositional tunability. A 10 fold increase in the net photocurrent density towards sulfite oxidation was measured for the nanocomposite with the lowest loading of WO3 (\u3b2-Cu2V2O7\u2006:\u2006WO3 = 1\u2006:\u20060.1) as compared to the bare \u3b2-Cu2V2O7 counterpart. This improvement is attributed to the formation of an intimate junction between the two metal oxides which favors charge transfer and separation. An increase in the WO3 content results in the formation of macroscopic phase segregated domains which reduce these interfacial areas, thus degrading the phototoelectrochemical performance of the nanocomposites. While highlighting the effectiveness of heterostructuring and the importance of compositional tunability, this study points at the emerging need of techniques to control and to probe the intrinsic inhomogeneity of these complex inorganic heterojunctions
Interrelation of Physical and Chemical Properties in Flow of Colloidal Suspensions in Porous Media
Additional file 1 of Protein secretion zones during overexpression of amylase within the Gram-positive cell wall
Additional file 1: Fig. S1. Western blot showing the presence of SecDF-mNeonGreen and SecA-mNeonGreen fusion proteins
Contemporary environmental assessment using a viability analysis in a large river system to inform restoration and adaptive management decisions
- …
