445 research outputs found

    A Risky enterprise: the Aldine edition of Galen, the failures of the editors, and the shadow of Erasmus of Rotterdam

    Get PDF
    The Aldine edition of Galen, awaited for more than 25 years, was perhaps the most risky enterprise in the whole history of the publishing house, and it almost brought Aldus’ heirs to bankruptcy. Although the editors were among the most renowned specialists of the time, the edition was harshly criticized by one former friend and collaborator of Aldus, Desiderius Erasmus of Rotterdam. Why? Was the edition so bad, were the manuscripts on which the edition was based responsible for its quality? Or were there other reasons for Erasmus’ complaint? The paper tries to give some hints in order to answer such questions, arguing that the role of Erasmus in the assessment of the value of the edition should take us into Aldus’ house in the period of the late fifteenth and early sixteenth century, and into the political and religious debate of the time

    Su Esichio e i cosiddetti frammenti del Glossario Ippocratico di Erotiano

    Get PDF

    Shipwreck with Spectator : Epidemics and society in the ancient world

    Get PDF

    On the Properties of a Bundle of Flexible Actin Filaments in an Optical Trap

    Get PDF
    We establish the Statistical Mechanics framework for a bundle of Nf living and uncrosslinked actin filaments in a supercritical solution of free monomers pressing against a mobile wall. The filaments are anchored normally to a fixed planar surface at one of their ends and, because of their limited flexibility, they grow almost parallel to each other. Their growing ends hit a moving obstacle, depicted as a second planar wall, parallel to the previous one and subjected to a harmonic compressive force. The force constant is denoted as trap strength while the distance between the two walls as trap length to make contact with the experimental optical trap apparatus. For an ideal solution of reactive filaments and free monomers at fixed free monomers chemical potential, we obtain the general expression for the grand potential from which we derive averages and distributions of relevant physical quantities, namely the obstacle position, the bundle polymerization force and the number of filaments in direct contact with the wall. The grafted living filaments are modeled as discrete Wormlike chains, with Factin persistence length, subject to discrete contour length variations to model single monomer (de)polymerization steps. Rigid filaments, either isolated or in bundles, all provide average values of the stalling force in agreement with Hill's predictions, independent of the average trap length. Flexible filaments instead, for values of the trap strength suitable to prevent their lateral escape, provide an average bundle force and an average trap length slightly larger than the corresponding rigid cases (few percents). Still the stalling force remains nearly independent on the average trap length, but results from the product of two strongly L dependent contributions: the fraction of touching filaments and the single filament buckling force.Comment: 21 pages, 8 figure

    PV Cell Characteristic Extraction to Verify Power Transfer Efficiency in Indoor Harvesting System

    Get PDF
    A method is proposed to verify the efficiency of low-power harvesting systems based on Photovoltaic (PV) cells for indoor applications and a Fractional Open-Circuit Voltage (FOCV) technique to track the Maximum Power Point (MPP). It relies on an algorithm to reconstruct the PV cell Power versus Voltage (P-V) characteristic measuring the open circuit voltage and the voltage/current operating point but not the short-circuit current as required by state-of-the-art algorithms. This way the characteristic is reconstructed starting from the two values corresponding to standard operation modes of dc-dc converters implementing the FOCV Maximum Power Point Tracking (MPPT) technique. The method is applied to a prototype system: an external board is connected between the transducer and the dc-dc converter to measure the open circuit voltage and the voltage/current operating values. Experimental comparisons between the reconstructed and the measured P-V characteristics validate the reconstruction algorithm. Experimental results show the method is able to clearly identify the error between the transducer operating point and the one corresponding to the maximum power transfer, whilst also suggesting corrective action on the programmable factor of the FOCV technique. The proposed technique therefore provides a possible way of estimating MPPT efficiency without sampling the full P-V characteristic

    Relationship between blood remifentanil concentration and stress hormone levels during pneumoperitoneum in patients undergoing laparoscopic cholecystectomy

    Get PDF
    The effect of remifentanil on stress response to surgery is unclear. However, there are not clinical studies investigating the relationship between blood remifentanil concentrations and stress hormones. Therefore, the aim of the present study was to assess the association between blood remifentanil concentrations measured after pneumoperitoneum and cortisol (CORT) or prolactin (PRL) ratio (intraoperative/preoperative value), in patients undergoing laparoscopic cholecystectom

    A coordinate deregulation of microRNAs expressed in mucosa adjacent to tumor predicts relapse after resection in localized colon cancer

    Get PDF
    Up to 20% of colorectal cancer (CRC) node-negative patients develop loco-regional or distant recurrences within 5 years from surgery. No predictive biomarker able to identify the node-negative subjects at high risk of relapse after curative treatment is presently available.Forty-eight localized (i.e. stage I-II) colon cancer patients who underwent radical tumor resection were considered. The expression of five miRNAs, involved in CRC progression, was investigated by qRT-PCR in both tumor tissue and matched normal colon mucosa.Interestingly, we found that the coordinate deregulation of four miRNAs (i.e. miR-18a, miR-21, miR-182 and miR-183), evaluated in the normal mucosa adjacent to tumor, is predictive of relapse within 55 months from curative surgery.Our results, if confirmed in independent studies, may help to identify high-risk patients who could benefit most from adjuvant therapy. Moreover, this work highlights the importance of extending the search for tissue biomarkers also to the tumor-adjacent mucosa

    Role of surgical setting and patients-related factors in predicting the occurrence of postoperative pulmonary complications after abdominal surgery

    Get PDF
    OBJECTIVE: The aim of this retrospective study was to evaluate the role of surgical setting (urgent vs. elective) and approach (open vs. laparoscopic) in affecting postoperative pulmonary complications (PPCs) prevalence in patients undergoing abdominal surgery. PATIENTS AND METHODS: After local Ethical Committee approval, 409 patients who had undergone abdominal surgery between January and December 2014 were included in the final analysis. PPCs were defined as the development of one of the following new findings: respiratory failure, pulmonary infection, aspiration pneumonia, pleural effusion, pneumothorax, atelectasis on chest X-ray, bronchospasm or un-planned urgent re-intubation. RESULTS: PPCs prevalence was greater in urgent (33%) vs. elective setting (7%) (chi(2) with Yates correction: 44; p=0.0001) and in open (6%) vs. laparoscopic approach (1.9%) (chi(2) with Yates correction: 12; p=0.0006). PPCs occurrence was positively correlated with in-hospital mortality (Biserial Correlation r=0.37; p=0.0001). Logistic regression showed that urgent setting (p=0.000), Ariscat (Assess Respiratory Risk in Surgical Patients in Catalonia) score (p=0.004), and age (p=0.01) were predictors of PPCs. A cutoff of 23 for Ariscat score was also identified as determining factor for PPCs occurrence with 94% sensitivity and 29% specificity. CONCLUSIONS: Patients undergoing abdominal surgery in an urgent setting were exposed to a higher risk of PPCs compared to patients scheduled for elective procedures. Ariscat score fitted with PPCs prevalence and older patients were exposed to a higher risk of PPCs. Prospective studies are needed to confirm these result

    Regional differences in the three-dimensional bone microstructure of the radial head:implications for observed fracture patterns

    Get PDF
    Introduction: A characterization of the internal bone microstructure of the radial head could provide a better understanding of commonly occurring fracture patterns frequently involving the (antero)lateral quadrant, for which a clear explanation is still lacking. The aim of this study is to describe the radial head bone microstructure using micro-computed tomography (micro-CT) and to relate it to gross morphology, function and possible fracture patterns. Materials and methods: Dry cadaveric human radii were scanned by micro-CT (17 Όm/pixel, isotropic). The trabecular bone microstructure was quantified on axial image stacks in four quadrants: the anterolateral (AL), posterolateral (PL), posteromedial (PM) and anteromedial (AM) quadrant. Results: The AL and PL quadrants displayed the significantly lowest bone volume fraction and trabecular number (BV/TV range 12.3–25.1%, Tb.N range 0.73–1.16 mm−1) and highest trabecular separation (Tb.Sp range 0.59–0.82 mm), compared to the PM and AM quadrants (BV/TV range 19.9–36.9%, Tb.N range 0.96–1.61 mm−1, Tb.Sp range 0.45–0.74 mm) (p = 0.03). Conclusions: Our microstructural results suggest that the lateral side is the “weaker side”, exhibiting lower bone volume faction, less trabeculae and higher trabecular separation, compared to the medial side. As the forearm is pronated during most falls, the underlying bone microstructure could explain commonly observed fracture patterns of the radial head, particularly more often involving the AL quadrant. If screw fixation in radial head fractures is considered, surgeons should take advantage of the “stronger” bone microstructure of the medial side of the radial head, should the fracture line allow this

    A gated oscillator clock and data recovery circuit for nanowatt wake-up and data receivers

    Get PDF
    This article presents a data-startable baseband logic featuring a gated oscillator clock and data recovery (GO-CDR) circuit for nanowatt wake-up and data receivers (WuRxs). At each data transition, the phase misalignment between the data coming from the analog front-end (AFE) and the clock is cleared by the GO-CDR circuit, thus allowing the reception of long data streams. Any free-running frequency mismatch between the GO and the bitrate does not limit the number of receivable bits, but only the maximum number of equal consecutive bits (Nm). To overcome this limitation, the proposed system includes a frequency calibration circuit, which reduces the frequency mismatch to ±0.5%, thus enabling the WuRx to be used with different encoding techniques up to Nm = 100. A full WuRx prototype, including an always-on clockless AFE operating in subthreshold, was fabricated with STMicroelectronics 90 nm BCD technology. The WuRx is supplied with 0.6 V, and the power consumption, excluding the calibration circuit, is 12.8 nW during the rest state and 17 nW at a 1 kbps data rate. With a 1 kbps On-Off Keying (OOK) modulated input and −35 dBm of input RF power after the input matching network (IMN), a 10^(−3) missed detection rate with a 0 bit error tolerance is measured, transmitting 63 bit packets with the Nm ranging from 1 to 63. The total sensitivity, including the estimated IMN gain at 100 MHz and 433 MHz, is −59.8 dBm and −52.3 dBm, respectively. In comparison with an ideal CDR, the degradation of the sensitivity due to the GO-CDR is 1.25 dBm. False alarm rate measurements lasting 24 h revealed zero overall false wake-ups
    • 

    corecore