149 research outputs found

    Radio-frequency magnetometry using a single electron spin

    Full text link
    We experimentally demonstrate a simple and robust protocol for the detection of weak radio-frequency magnetic fields using a single electron spin in diamond. Our method relies on spin locking, where the Rabi frequency of the spin is adjusted to match the MHz signal frequency. In a proof-of-principle experiment we detect a 7.5 MHz magnetic probe field of 40 nT amplitude with <10 kHz spectral resolution over a T_1-limited noise floor of 0.3 nT/rtHz. Rotating-frame magnetometry may provide a direct and sensitive route to high-resolution spectroscopy of nanoscale nuclear spin signals

    The off-axis channel macroplate

    Get PDF
    High-gain microchannel plates (MCPs) which utilize curvature of the channel to inhibit ion feedback (C-plate MCRs) have demonstrated excellent performance characteristics. However, C-plate MCPs are at present costly to fabricate, and the shearing process used to curve the channels produces a low device yield. Described here is a totally new type of high-gain MCP structure in which each channel has an axially symmetric curvature. Initial tests of proof-of-concept units of these MCPs with 75-micron-diameter channels (macroplates) suggest that their performance characteristics have the potential to be equal to those of a C-plate MCP while the fabrication process is no more complex than that of a conventional straight-channel MCP

    Spurious harmonic response of multipulse quantum sensing sequences

    Full text link
    Multipulse sequences based on Carr-Purcell decoupling are frequently used for narrow-band signal detection in single spin magnetometry. We have analyzed the behavior of multipulse sensing sequences under real-world conditions, including finite pulse durations and the presence of detunings. We find that these non-idealities introduce harmonics to the filter function, allowing additional frequencies to pass the filter. In particular, we find that the XY family of sequences can generate signals at the 2fac, 4fac and 8fac harmonics and their odd subharmonics, where fac is the ac signal frequency. Consideration of the harmonic response is especially important for diamond-based nuclear spin sensing where the NMR frequency is used to identify the nuclear spin species, as it leads to ambiguities when several isotopes are present.Comment: 6 pages, 7 figure

    Nanoscale nuclear magnetic resonance with a 1.9-nm-deep nitrogen-vacancy sensor

    Get PDF
    We present nanoscale nuclear magnetic resonance (NMR) measurements performed with nitrogen-vacancy (NV) centers located down to about 2 nm from the diamond surface. NV centers were created by shallow ion implantation followed by a slow, nanometer-by-nanometer removal of diamond material using oxidative etching in air. The close proximity of NV centers to the surface yielded large 1H NMR signals of up to 3.4 lT-rms, corresponding to ~330 statistically polarized or ~10 fully polarized proton spins in a (1.8 nm)3 detection volume

    The management of diabetic foot: A clinical practice guideline by the Society for Vascular Surgery in collaboration with the American Podiatric Medical Association and the Society for Vascular Medicine

    Get PDF
    BACKGROUND: Diabetes mellitus continues to grow in global prevalence and to consume an increasing amount of health care resources. One of the key areas of morbidity associated with diabetes is the diabetic foot. To improve the care of patients with diabetic foot and to provide an evidence-based multidisciplinary management approach, the Society for Vascular Surgery in collaboration with the American Podiatric Medical Association and the Society for Vascular Medicine developed this clinical practice guideline. METHODS: The committee made specific practice recommendations using the Grades of Recommendation Assessment, Development, and Evaluation system. This was based on five systematic reviews of the literature. Specific areas of focus included (1) prevention of diabetic foot ulceration, (2) off-loading, (3) diagnosis of osteomyelitis, (4) wound care, and (5) peripheral arterial disease. RESULTS: Although we identified only limited high-quality evidence for many of the critical questions, we used the best available evidence and considered the patients' values and preferences and the clinical context to develop these guidelines. We include preventive recommendations such as those for adequate glycemic control, periodic foot inspection, and patient and family education. We recommend using custom therapeutic footwear in high-risk diabetic patients, including those with significant neuropathy, foot deformities, or previous amputation. In patients with plantar diabetic foot ulcer (DFU), we recommend off-loading with a total contact cast or irremovable fixed ankle walking boot. In patients with a new DFU, we recommend probe to bone test and plain films to be followed by magnetic resonance imaging if a soft tissue abscess or osteomyelitis is suspected. We provide recommendations on comprehensive wound care and various débridement methods. For DFUs that fail to improve (>50% wound area reduction) after a minimum of 4 weeks of standard wound therapy, we recommend adjunctive wound therapy options. In patients with DFU who have peripheral arterial disease, we recommend revascularization by either surgical bypass or endovascular therapy. CONCLUSIONS: Whereas these guidelines have addressed five key areas in the care of DFUs, they do not cover all the aspects of this complex condition. Going forward as future evidence accumulates, we plan to update our recommendations accordingly

    Release of engineered nanomaterials from personal care products throughout their life cycle

    Full text link
    The impetus for this study was to provide release estimates that can serve to improve predictions of engineered nanomaterial (ENM) exposure for risk assessment. We determined the likely release of ENMs from personal care products (PCPs) through a consumer survey on use and disposal habits, and research on the types and quantities of ENMs in PCPs. Our estimates show that in the US zinc oxide (ZnO), with 1,800-2,100 mt yr-1, and titanium dioxide (TiO2), with 870-1,000 mt yr-1, represent 94 % of ENMs released into the environment or landfills from the use of PCPs. Around 36-43 % of ENMs from PCPs were estimated to end up in landfills, 24-36 % released to soils, 0.7-0.8 % to air, and 28-32 % to water bodies. ENMs in sunscreen represent around 81-82 % of total release, from ZnO and TiO2 as UV blockers, followed by facial moisturizer (7.5 %), foundation (5.7 %), and hair coloring products (3.1 %). Daily care products such as body wash, shampoo, and conditioner had by far the highest per capita and total use, but contributed little to the ENM release estimates as these products generally contain little or no ENMs. However, if ENMs are incorporated into these daily care products, this may substantially increase ENM release. © 2014 Springer Science+Business Media

    Edible bio-based nanostructures: delivery, absorption and potential toxicity

    Get PDF
    The development of bio-based nanostructures as nanocarriers of bioactive compounds to specific body sites has been presented as a hot topic in food, pharmaceutical and nanotechnology fields. Food and pharmaceutical industries seek to explore the huge potential of these nanostructures, once they can be entirely composed of biocompatible and non-toxic materials. At the same time, they allow the incorporation of lipophilic and hydrophilic bioactive compounds protecting them against degradation, maintaining its active and functional performance. Nevertheless, the physicochemical properties of such structures (e.g., size and charge) could change significantly their behavior in the gastrointestinal (GI) tract. The main challenges in the development of these nanostructures are the proper characterization and understanding of the processes occurring at their surface, when in contact with living systems. This is crucial to understand their delivery and absorption behavior as well as to recognize potential toxicological effects. This review will provide an insight into the recent innovations and challenges in the field of delivery via GI tract using bio-based nanostructures. Also, an overview of the approaches followed to ensure an effective deliver (e.g., avoiding physiological barriers) and to enhance stability and absorptive intestinal uptake of bioactive compounds will be provided. Information about nanostructures potential toxicity and a concise description of the in vitro and in vivo toxicity studies will also be given.Joana T. Martins, Oscar L. Ramos, Ana C. Pinheiro, Ana I. Bourbon, Helder D. Silva and Miguel A. Cerqueira (SFRH/BPD/89992/2012, SFRH/BPD/80766/2011, SFRH/BPD/101181/2014, SFRH/BD/73178/2010, SFRH/BD/81288/2011, and SFRH/BPD/72753/2010, respectively) are the recipients of a fellowship from the Fundacao para a Ciencia e Tecnologia (FCT, POPH-QREN and FSE, Portugal). The authors thank the FCT Strategic Project PEst-OE/EQB/LA0023/2013 and the project "BioInd-Biotechnology and Bioengineering for improved Industrial and Agro-Food processes," REF.NORTE-07-0124-FEDER-000028, co-funded by the Programa Operacional Regional do Norte (ON.2-O Novo Norte), QREN, FEDER. We also thank to the European Commission: BIOCAPS (316265, FP7/REGPOT-2012-2013.1) and Xunta de Galicia: Agrupamento INBIOMED (2012/273) and Grupo con potencial de crecimiento. The support of EU Cost Action FA1001 is gratefully acknowledged
    corecore