322 research outputs found

    Quantification of Degradation of Chlorinated Hydrocarbons in Saturated Low Permeability Sediments Using Compound-Specific Isotope Analysis

    Get PDF
    This field and modeling study aims to reveal if degradation of chlorinated hydrocarbons in low permeability sediments can be quantified using compound-specific isotope analysis (CSIA). For that purpose, the well-characterized Borden research site was selected, where an aquifer−aquitard system was artificially contaminated by a three component chlorinated solvent mixture (tetrachloroethene (PCE) 45 vol %, trichloroethene (TCE) 45 vol %, and chloroform (TCM) 10 vol %). Nearly 15 years after the contaminant release, several high-resolution concentration and CSIA profiles were determined for the chlorinated hydrocarbons that had diffused into the clayey aquitard. The CSIA profiles showed large shifts of carbon isotope ratios with depth (up to 24‰) suggesting that degradation occurs in the aquitard despite the small pore sizes. Simulated scenarios without or with uniform degradation failed to reproduce the isotope data, while a scenario with decreasing degradation with depth fit the data well. This suggests that nutrients had diffused into the aquitard favoring stronger degradation close to the aquifer−aquitard interface than with increasing depth. Moreover, the different simulation scenarios showed that CSIA profiles are more sensitive to different degradation conditions compared to concentration profiles highlighting the power of CSIA to constrain degradation activities in aquitards

    Dual-Element Isotope Analysis of Desphenylchloridazon to Investigate its Environmental Fate in a Systematic Field Study-A Long-Term Lysimeter Experiment

    Get PDF
    Desphenylchloridazon (DPC), the main metabolite of the herbicide chloridazon (CLZ), is more water soluble and persistent than CLZ and frequently detected in water bodies. When assessing DPC transformation in the environment, results can be nonconclusive if based on concentration analysis alone because estimates may be confounded by simultaneous DPC formation from CLZ. This study investigated the fate of DPC by combining concentration-based methods with compound-specific C and N stable isotope analysis (CSIA). Additionally, DPC formation and transformation processes were experimentally deconvolved in a dedicated lysimeter study considering three scenarios. First, surface application of DPC enabled studying its degradation in the absence of CLZ. Here, CSIA provided evidence of two distinct DPC transformation processes: one shows significant changes only in 13C/12C, whereas the other involves changes in both 13C/12C and 15N/14N isotope ratios. Second, surface application of CLZ mimicked a realistic field scenario, showing that during DPC formation, 13C/12C ratios of DPC were depleted in 13C relative to CLZ, while 15N/14N ratios remained constant. Finally, CLZ depth injection simulated preferential flow and demonstrated the importance of the topsoil for retaining DPC. The combination of the lysimeter study with CSIA enabled insights into DPC transformation in the field that are superior to those of studies of concentration trends

    A review of RCTs in four medical journals to assess the use of imputation to overcome missing data in quality of life outcomes

    Get PDF
    Background: Randomised controlled trials (RCTs) are perceived as the gold-standard method for evaluating healthcare interventions, and increasingly include quality of life (QoL) measures. The observed results are susceptible to bias if a substantial proportion of outcome data are missing. The review aimed to determine whether imputation was used to deal with missing QoL outcomes. Methods: A random selection of 285 RCTs published during 2005/6 in the British Medical Journal, Lancet, New England Journal of Medicine and Journal of American Medical Association were identified. Results: QoL outcomes were reported in 61 (21%) trials. Six (10%) reported having no missing data, 20 (33%) reported ≤ 10% missing, eleven (18%) 11%–20% missing, and eleven (18%) reported >20% missing. Missingness was unclear in 13 (21%). Missing data were imputed in 19 (31%) of the 61 trials. Imputation was part of the primary analysis in 13 trials, but a sensitivity analysis in six. Last value carried forward was used in 12 trials and multiple imputation in two. Following imputation, the most common analysis method was analysis of covariance (10 trials). Conclusion: The majority of studies did not impute missing data and carried out a complete-case analysis. For those studies that did impute missing data, researchers tended to prefer simpler methods of imputation, despite more sophisticated methods being available.The Health Services Research Unit is funded by the Chief Scientist Office of the Scottish Government Health Directorate. Shona Fielding is also currently funded by the Chief Scientist Office on a Research Training Fellowship (CZF/1/31)

    Monitoring of northern climate exposure

    Get PDF
    Currently, facility managers are faced with many advanced decisions regarding when and how to inspect, maintain, repair or renew existing facilities in a costeffective manner. The evolution of the deteriorations of road structures in reinforced concrete depends on the exposure of the elements to water in liquid form or vapour and to other aggressive agents such as chloride. Current models of ionic transport neglect the effect of real ionic concentration in contact with concrete structures, it means boundary conditions are considered with simple tendency as uniform concentration during the winter period and model parameters are derived from the fitting method. Therefore, it implies in ineffective prediction models of deterioration, i.e. steel rebar corrosion by chloride presence or carbonation, alkali-granular reaction, acid attacks, etc. Structure are sensitive to their environment and their interaction with it is directly related to the processes of deterioration. The degradation of structures exposed to salt-laden mist is faster in the wetter areas. On the contrary, the deterioration of the structures caused by salt spray in the drier zone is slower. The structures, exposed to splashing (precipitation, wind, splash, etc.), have a slower rate of degradation in the wetter regions. The amount of rain has an indirect effect in the process of deterioration of the structure exposed to salt-laden mist because it changes the contact time of chloride on the surface of the structures. For this purpose, a unique exposure monitoring was developed. This mobile station, named MExStUL, contains an atmospheric sensor and new possibilities of chloride detection contained in splashes, mist and static water near the road improving the real exposure of structure and the boundary conditions. First results highlight the real influence of environmental parameters on structures durability on highways. Salt concentration is not uniform during winter period and water thickness demonstrate important periods of drying

    Factors influencing variation in physician adenoma detection rates: a theory-based approach for performance improvement

    Get PDF
    BACKGROUND AND AIMS: Interventions to improve physician adenoma detection rates for colonoscopy have generally not been successful, and there are little data on the factors contributing to variation that may be appropriate targets for intervention. We sought to identify factors that may influence variation in detection rates by using theory-based tools for understanding behavior. METHODS: We separately studied gastroenterologists and endoscopy nurses at 3 Kaiser Permanente Northern California medical centers to identify potentially modifiable factors relevant to physician adenoma detection rate variability by using structured group interviews (focus groups) and theory-based tools for understanding behavior and eliciting behavior change: the Capability, Opportunity, and Motivation behavior model; the Theoretical Domains Framework; and the Behavior Change Wheel. RESULTS: Nine factors potentially associated with adenoma detection rate variability were identified, including 6 related to capability (uncertainty about which types of polyps to remove, style of endoscopy team leadership, compromised ability to focus during an examination due to distractions, examination technique during withdrawal, difficulty detecting certain types of adenomas, and examiner fatigue and pain), 2 related to opportunity (perceived pressure due to the number of examinations expected per shift and social pressure to finish examinations before scheduled breaks or the end of a shift), and 1 related to motivation (valuing a meticulous examination as the top priority). Examples of potential intervention strategies are provided. CONCLUSIONS: By using theory-based tools, this study identified several novel and potentially modifiable factors relating to capability, opportunity, and motivation that may contribute to adenoma detection rate variability and be appropriate targets for future intervention trials
    corecore