775 research outputs found

    Field Theory And Second Renormalization Group For Multifractals In Percolation

    Full text link
    The field-theory for multifractals in percolation is reformulated in such a way that multifractal exponents clearly appear as eigenvalues of a second renormalization group. The first renormalization group describes geometrical properties of percolation clusters, while the second-one describes electrical properties, including noise cumulants. In this context, multifractal exponents are associated with symmetry-breaking fields in replica space. This provides an explanation for their observability. It is suggested that multifractal exponents are ''dominant'' instead of ''relevant'' since there exists an arbitrary scale factor which can change their sign from positive to negative without changing the Physics of the problem.Comment: RevTex, 10 page

    Postural adaptations to unilateral knee joint hypomobility induced by orthosis wear during gait initiation

    Get PDF
    Abstract Balance control and whole-body progression during gait initiation (GI) involve knee-joint mobility. Single knee-joint hypomobility often occurs with aging, orthopedics or neurological conditions. The goal of the present study was to investigate the capacity of the CNS to adapt GI organization to single knee-joint hypomobility induced by the wear of an orthosis. Twenty-seven healthy adults performed a GI series on a force-plate in the following conditions: without orthosis ("control"), with knee orthosis over the swing leg ("orth-swing") and with the orthosis over the contralateral stance leg ("orth-stance"). In orth-swing, amplitude of mediolateral anticipatory postural adjustments (APAs) and step width were larger, execution phase duration longer, and anteroposterior APAs smaller than in control. In orth-stance, mediolateral APAs duration was longer, step width larger, and amplitude of anteroposterior APAs smaller than in control. Consequently, step length and progression velocity (which relate to the "motor performance") were reduced whereas stability was enhanced compared to control. Vertical force impact at foot-contact did not change across conditions, despite a smaller step length in orthosis conditions compared to control. These results show that the application of a local mechanical constraint induced profound changes in the global GI organization, altering motor performance but ensuring greater stability

    Direct fiber comb stabilization to a gas-filled hollow-core photonic crystal fiber

    Get PDF
    We have isolated a single tooth from a fiber laser-based optical frequency comb for nonlinear spectroscopy and thereby directly referenced the comb. An 89 MHz erbium fiber laser frequency comb is directly stabilized to the P(23) (1539.43 nm) overtone transition of [superscript]12C[subscript]2H[subscript]2 inside a hollow-core photonic crystal fiber. To do this, a single comb tooth is isolated and amplified from 20 nW to 40 mW with sufficient fidelity to perform saturated absorption spectroscopy. The fractional stability of the comb, ~7 nm away from the stabilized tooth, is shown to be 6 × 10[superscript]−12 at 100 ms gate time, which is over an order of magnitude better than that of a comb referenced to a GPS-disciplined Rb oscillator

    Bond-charge Interaction in the extended Hubbard chain

    Full text link
    We study the effects of bond-charge interaction (or correlated hopping) on the properties of the extended ({\it i.e.,} with both on-site (UU) and nearest-neighbor (VV) repulsions) Hubbard model in one dimension at half-filling. Energy gaps and correlation functions are calculated by Lanczos diagonalization on finite systems. We find that, irrespective of the sign of the bond-charge interaction, XX, the charge--density-wave (CDW) state is more robust than the spin--density-wave (SDW) state. A small bond-charge interaction term is enough to make the differences between the CDW and SDW correlation functions much less dramatic than when X=0X=0. For X=tX=t and fixed V<2tV<2t (tt is the uncorrelated hopping integral), there is an intermediate phase between a charge ordered phase and a phase corresponding to singly-occupied sites, the nature of which we clarify: it is characterized by a succession of critical points, each of which corresponding to a different density of doubly-occupied sites. We also find an unusual slowly decaying staggered spin-density correlation function, which is suggestive of some degree of ordering. No enhancement of pairing correlations was found for any XX in the range examined.Comment: 10 pages, 7 PostScript figures, RevTeX 3; to appear in Phys Rev

    Bronchogenic cyst excision using a robotic laparoscopic transdiaphragmatic approach

    Get PDF
    AbstractWe describe one case of a bronchopulmonary foregut malformations (BPFM) excision using robotic technology in a pediatric patient. Traditionally, surgical resection is performed using a thoracotomy or video-assisted thoracic surgery. A 12-year-old girl with a previous medical history of cough was diagnosed with a left cystic paracardiac mass. Her operation employed a transdiaphragmatic approach to remove the mass. The postoperative course was uneventful, and she was discharged after four days. The subsequent pathology concluded that the mass was a bronchogenic cyst. To the best of our knowledge, this is the first report of transdiaphragmatic laparoscopic approach and first use of robotics-platform for BPFM excision by children. We elected to use this type of procedure to decrease the postoperative morbidity associated with the thoracic approach. The robotic technology permitted surgical resection with a similar efficiency as standard thoracic or laparoscopic procedures. We hypothesized that this technology would simplify some of the technical points, decreasing any postoperative complications

    Postoperative bladder dysfunction and outcomes after minimally invasive extravesical ureteric reimplantation in children using a laparoscopic and a robot-assisted approach: results of a multicentre international survey

    Get PDF
    OBJECTIVES: To assess and compare postoperative bladder dysfunction rates and outcomes after laparoscopic and robot-assisted extravesical ureteric reimplantation in children and to identify risk factors associated with bladder dysfunction. PATIENTS AND METHODS: A total of 151 children underwent minimally invasive extravesical ureteric reimplantation in five international centres of paediatric urology over a 5-year period (January 2013-January 2018). The children were divided in two groups according to surgical approach: group 1 underwent laporoscopic reimplantation and included 116 children (92 girls and 24 boys with a median age of 4.5 years), while group 2 underwent robot-assisted reimplantation and included 35 children (29 girls and six boys with a median age of 7.5 years). The two groups were compared with regard to: procedure length; success rate; postoperative complication rate; and postoperative bladder dysfunction rate (acute urinary retention [AUR] and voiding dysfunction). Univariate and multivariate logistic regression analyses were performed to assess predictors of postoperative bladder dysfunction. Factors assessed included age, gender, laterality, duration of procedure, pre-existing bladder and bowel dysfunction (BBD) and pain control. RESULTS: The mean operating time was significantly longer in group 2 compared with group 1, for both unilateral (159.5 vs 109.5 min) and bilateral procedures (202 vs 132 min; P = 0.001). The success rate was significantly higher in group 2 than in group 1 (100% vs 95.6%; P = 0.001). The overall postoperative bladder dysfunction rate was 8.6% and no significant difference was found between group 1 (6.9%) and group 2 (14.3%; P = 0.17). All AUR cases were managed with short-term bladder catheterization except for two cases (1.3%) in group 1 that required short-term suprapubic catheterization. Univariate and multivariate analyses showed that bilateral pathology, pre-existing BBD and duration of procedure were predictors of postoperative bladder dysfunction (P = 0.001). CONCLUSION: Our results confirmed that short-term bladder dysfunction is a possible complication of extravesical ureteric reimplantation, with no significant difference between the laparoscopic and robot-assisted approaches. Bladder dysfunction occurred more often after bilateral repairs, but required suprapubic catheterization in only 1.3% of cases. Bilaterality, pre-existing BBD and duration of surgery were confirmed on univariate and multivariate analyses as predictors of postoperative bladder dysfunction in this series

    In-situ surface technique analyses and ex-situ characterization of Si1-xGex epilayers grown on Si(001)-2 ×1 by molecular beam epitaxy

    No full text
    Si1-xGex epilayers grown by Molecular Beam Epitaxy on Si(001) at 400 â—‹C have been analyzed in-situ by surface techniques such as X-ray and Ultraviolet Photoelectron Spectroscopies (XPS and UPS), Low Energy Electron Diffraction (LEED) and photoelectron diffraction (XPD). The Ge surface concentrations (x) obtained from the ratios of Ge and Si core level intensities are systematically higher than those obtained by the respective evaporation fluxes. This indicates a Ge enrichment in the first overlayers confirmed by Ge-like UPS valence band spectra. The structured crystallographic character of the epilayers is ascertained by LEED and XPD polar scans in the (100) plane since the Ge Auger LMM and the Si 2p XPD intensity patterns from the Si1-xGex epilayers are identical to those of the Si substrate. The residual stress in the epilayer is determined by ex-situ X-ray diffraction (XRD) which also allows, as Rutherford Back Scattering (RBS), Ge concentration determinations

    Comparative chloroplast genomics: analyses including new sequences from the angiosperms Nuphar advena and Ranunculus macranthus

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The number of completely sequenced plastid genomes available is growing rapidly. This array of sequences presents new opportunities to perform comparative analyses. In comparative studies, it is often useful to compare across wide phylogenetic spans and, within angiosperms, to include representatives from basally diverging lineages such as the genomes reported here: <it>Nuphar advena </it>(from a basal-most lineage) and <it>Ranunculus macranthus </it>(a basal eudicot). We report these two new plastid genome sequences and make comparisons (within angiosperms, seed plants, or all photosynthetic lineages) to evaluate features such as the status of <it>ycf15 </it>and <it>ycf68 </it>as protein coding genes, the distribution of simple sequence repeats (SSRs) and longer dispersed repeats (SDR), and patterns of nucleotide composition.</p> <p>Results</p> <p>The <it>Nuphar </it>[GenBank:<ext-link ext-link-type="gen" ext-link-id="NC_008788">NC_008788</ext-link>] and <it>Ranunculus </it>[GenBank:<ext-link ext-link-type="gen" ext-link-id="NC_008796">NC_008796</ext-link>] plastid genomes share characteristics of gene content and organization with many other chloroplast genomes. Like other plastid genomes, these genomes are A+T-rich, except for rRNA and tRNA genes. Detailed comparisons of <it>Nuphar </it>with <it>Nymphaea</it>, another Nymphaeaceae, show that more than two-thirds of these genomes exhibit at least 95% sequence identity and that most SSRs are shared. In broader comparisons, SSRs vary among genomes in terms of abundance and length and most contain repeat motifs based on A and T nucleotides.</p> <p>Conclusion</p> <p>SSR and SDR abundance varies by genome and, for SSRs, is proportional to genome size. Long SDRs are rare in the genomes assessed. SSRs occur less frequently than predicted and, although the majority of the repeat motifs do include A and T nucleotides, the A+T bias in SSRs is less than that predicted from the underlying genomic nucleotide composition. In codon usage third positions show an A+T bias, however variation in codon usage does not correlate with differences in A+T-richness. Thus, although plastome nucleotide composition shows "A+T richness", an A+T bias is not apparent upon more in-depth analysis, at least in these aspects. The pattern of evolution in the sequences identified as <it>ycf15 </it>and <it>ycf68 </it>is not consistent with them being protein-coding genes. In fact, these regions show no evidence of sequence conservation beyond what is normal for non-coding regions of the IR.</p
    • …
    corecore