79 research outputs found

    Seen but not considered? Awareness and consideration in choice analysis

    Get PDF
    Consideration set formation (CSF) is a two-stage decision process in which people first select a subset of products to consider and then evaluate and choose from the selected subset of products. CSF models typically use stated consideration or infer it from choice data probabilistically. This study explores CSF by means of eye-tracking and evaluates how measures of visual consideration compare to stated consideration. We develop a model of CSF behavior, where stated and visual consideration are embedded in the specification of the utility function. We propose three different measures of visual consideration and show that one third of respondents (similar to 34%) use CSF behavior and that stated consideration diverges substantially from visual consideration. Surprisingly, many product types stated as not considered receive more visual attention, not less. Our findings suggest that stated consideration may be in part a measure of preferences rather than of consideration, implying concerns with endogeneity when including stated consideration data in choice models. Accounting for CSF in discrete choice analysis increases our understanding of the decision process, and can target concerns with biased estimates when analyzing data from two-stage decision processes

    Convolutional neural network-based automatic heart segmentation and quantitation in 123I-metaiodobenzylguanidine SPECT imaging

    Get PDF
    Background: Since three-dimensional segmentation of cardiac region in 123I-metaiodobenzylguanidine (MIBG) study has not been established, this study aimed to achieve organ segmentation using a convolutional neural network (CNN) with 123I-MIBG single photon emission computed tomography (SPECT) imaging, to calculate heart counts and washout rates (WR) automatically and to compare with conventional quantitation based on planar imaging. Methods: We assessed 48 patients (aged 68.4 \ub1 11.7\ua0years) with heart and neurological diseases, including chronic heart failure, dementia with Lewy bodies, and Parkinson\u27s disease. All patients were assessed by early and late 123I-MIBG planar and SPECT imaging. The CNN was initially trained to individually segment the lungs and liver on early and late SPECT images. The segmentation masks were aligned, and then, the CNN was trained to directly segment the heart, and all models were evaluated using fourfold cross-validation. The CNN-based average heart counts and WR were calculated and compared with those determined using planar parameters. The CNN-based SPECT and conventional planar heart counts were corrected by physical time decay, injected dose of 123I-MIBG, and body weight. We also divided WR into normal and abnormal groups from linear regression lines determined by the relationship between planar WR and CNN-based WR and then analyzed agreement between them. Results: The CNN segmented the cardiac region in patients with normal and reduced uptake. The CNN-based SPECT heart counts significantly correlated with conventional planar heart counts with and without background correction and a planar heart-to-mediastinum ratio (R2 = 0.862, 0.827, and 0.729, p < 0.0001, respectively). The CNN-based and planar WRs also correlated with and without background correction and WR based on heart-to-mediastinum ratios of R2 = 0.584, 0.568 and 0.507, respectively (p < 0.0001). Contingency table findings of high and low WR (cutoffs: 34% and 30% for planar and SPECT studies, respectively) showed 87.2% agreement between CNN-based and planar methods. Conclusions: The CNN could create segmentation from SPECT images, and average heart counts and WR were reliably calculated three-dimensionally, which might be a novel approach to quantifying SPECT images of innervation

    Applications of Artificial Intelligence in PSMA PET/CT for Prostate Cancer Imaging

    Get PDF
    Prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) has emerged as an important imaging technique for prostate cancer. The use of PSMA PET/CT is rapidly increasing, while the number of nuclear medicine physicians and radiologists to interpret these scans is limited. Additionally, there is variability in interpretation among readers. Artificial intelligence techniques, including traditional machine learning and deep learning algorithms, are being used to address these challenges and provide additional insights from the images. The aim of this scoping review was to summarize the available research on the development and applications of AI in PSMA PET/CT for prostate cancer imaging. A systematic literature search was performed in PubMed, Embase and Cinahl according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A total of 26 publications were included in the synthesis. The included studies focus on different aspects of artificial intelligence in PSMA PET/CT, including detection of primary tumor, local recurrence and metastatic lesions, lesion classification, tumor quantification and prediction/prognostication. Several studies show similar performances of artificial intelligence algorithms compared to human interpretation. Few artificial intelligence tools are approved for use in clinical practice. Major limitations include the lack of external validation and prospective design. Demonstrating the clinical impact and utility of artificial intelligence tools is crucial for their adoption in healthcare settings. To take the next step towards a clinically valuable artificial intelligence tool that provides quantitative data, independent validation studies are needed across institutions and equipment to ensure robustness

    RECOMIA - a cloud-based platform for artificial intelligence research in nuclear medicine and radiology

    Get PDF
    Background: Artificial intelligence (AI) is about to transform medical imaging. The Research Consortium for Medical Image Analysis (RECOMIA), a not-for-profit organisation, has developed an online platform to facilitate collaboration between medical researchers and AI researchers. The aim is to minimise the time and effort researchers need to spend on technical aspects, such as transfer, display, and annotation of images, as well as legal aspects, such as de-identification. The purpose of this article is to present the RECOMIA platform and its AI-based tools for organ segmentation in computed tomography (CT), which can be used for extraction of standardised uptake values from the corresponding positron emission tomography (PET) image. Results: The RECOMIA platform includes modules for (1) local de-identification of medical images, (2) secure transfer of images to the cloud-based platform, (3) display functions available using a standard web browser, (4) tools for manual annotation of organs or pathology in the images, (5) deep learning-based tools for organ segmentation or other customised analyses, (6) tools for quantification of segmented volumes, and (7) an export function for the quantitative results. The AI-based tool for organ segmentation in CT currently handles 100 organs (77 bones and 23 soft tissue organs). The segmentation is based on two convolutional neural networks (CNNs): one network to handle organs with multiple similar instances, such as vertebrae and ribs, and one network for all other organs. The CNNs have been trained using CT studies from 339 patients. Experienced radiologists annotated organs in the CT studies. The performance of the segmentation tool, measured as mean Dice index on a manually annotated test set, with 10 representative organs, was 0.93 for all foreground voxels, and the mean Dice index over the organs were 0.86 (0.82 for the soft tissue organs and 0.90 for the bones). Conclusion: The paper presents a platform that provides deep learning-based tools that can perform basic organ segmentations in CT, which can then be used to automatically obtain the different measurement in the corresponding PET image. The RECOMIA platform is available on request at www.recomia.org for research purposes

    AI-based detection of lung lesions in [18F]FDG PET-CT from lung cancer patients

    Get PDF
    Background: [ F]-fluorodeoxyglucose (FDG) positron emission tomography with computed tomography (PET-CT) is a well-established modality in the work-up of patients with suspected or confirmed diagnosis of lung cancer. Recent research efforts have focused on extracting theragnostic and textural information from manually indicated lung lesions. Both semi-automatic and fully automatic use of artificial intelligence (AI) to localise and classify FDG-avid foci has been demonstrated. To fully harness AI’s usefulness, we have developed a method which both automatically detects abnormal lung lesions and calculates the total lesion glycolysis (TLG) on FDG PET-CT. Methods: One hundred twelve patients (59 females and 53 males) who underwent FDG PET-CT due to suspected or for the management of known lung cancer were studied retrospectively. These patients were divided into a training group (59%; n = 66), a validation group (20.5%; n = 23) and a test group (20.5%; n = 23). A nuclear medicine physician manually segmented abnormal lung lesions with increased FDG-uptake in all PET-CT studies. The AI-based method was trained to segment the lesions based on the manual segmentations. TLG was then calculated from manual and AI-based measurements, respectively and analysed with Bland-Altman plots. Results: The AI-tool’s performance in detecting lesions had a sensitivity of 90%. One small lesion was missed in two patients, respectively, where both had a larger lesion which was correctly detected. The positive and negative predictive values were 88% and 100%, respectively. The correlation between manual and AI TLG measurements was strong (R = 0.74). Bias was 42 g and 95% limits of agreement ranged from − 736 to 819 g. Agreement was particularly high in smaller lesions. Conclusions: The AI-based method is suitable for the detection of lung lesions and automatic calculation of TLG in small- to medium-sized tumours. In a clinical setting, it will have an added value due to its capability to sort out negative examinations resulting in prioritised and focused care on patients with potentially malignant lesions

    Artificial intelligence-aided CT segmentation for body composition analysis: a validation study

    Get PDF
    Background: Body composition is associated with survival outcome in oncological patients, but it is not routinely calculated. Manual segmentation of subcutaneous adipose tissue (SAT) and muscle is time-consuming and therefore limited to a single CT slice. Our goal was to develop an artificial-intelligence (AI)-based method for automated quantification of three-dimensional SAT and muscle volumes from CT images. Methods: Ethical approvals from Gothenburg and Lund Universities were obtained. Convolutional neural networks were trained to segment SAT and muscle using manual segmentations on CT images from a training group of 50 patients. The method was applied to a separate test group of 74 cancer patients, who had two CT studies each with a median interval between the studies of 3 days. Manual segmentations in a single CT slice were used for comparison. The accuracy was measured as overlap between the automated and manual segmentations. Results: The accuracy of the AI method was 0.96 for SAT and 0.94 for muscle. The average differences in volumes were significantly lower than the corresponding differences in areas in a single CT slice: 1.8% versus 5.0% (p < 0.001) for SAT and 1.9% versus 3.9% (p < 0.001) for muscle. The 95% confidence intervals for predicted volumes in an individual subject from the corresponding single CT slice areas were in the order of \ub1 20%. Conclusions: The AI-based tool for quantification of SAT and muscle volumes showed high accuracy and reproducibility and provided a body composition analysis that is more relevant than manual analysis of a single CT slice

    An artificial neural network to safely reduce the number of ambulance ECGs transmitted for physician assessment in a system with prehospital detection of ST elevation myocardial infarction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pre-hospital electrocardiogram (ECG) transmission to an expert for interpretation and triage reduces time to acute percutaneous coronary intervention (PCI) in patients with ST elevation Myocardial Infarction (STEMI). In order to detect all STEMI patients, the ECG should be transmitted in all cases of suspected acute cardiac ischemia. The aim of this study was to examine the ability of an artificial neural network (ANN) to safely reduce the number of ECGs transmitted by identifying patients without STEMI and patients not needing acute PCI.</p> <p>Methods</p> <p>Five hundred and sixty ambulance ECGs transmitted to the coronary care unit (CCU) in routine care were prospectively collected. The ECG interpretation by the ANN was compared with the diagnosis (STEMI or not) and the need for an acute PCI (or not) as determined from the Swedish coronary angiography and angioplasty register. The CCU physician's real time ECG interpretation (STEMI or not) and triage decision (acute PCI or not) were registered for comparison.</p> <p>Results</p> <p>The ANN sensitivity, specificity, positive and negative predictive values for STEMI was 95%, 68%, 18% and 99%, respectively, and for a need of acute PCI it was 97%, 68%, 17% and 100%. The area under the ANN's receiver operating characteristics curve for STEMI detection was 0.93 (95% CI 0.89-0.96) and for predicting the need of acute PCI 0.94 (95% CI 0.90-0.97). If ECGs where the ANN did not identify a STEMI or a need of acute PCI were theoretically to be withheld from transmission, the number of ECGs sent to the CCU could have been reduced by 64% without missing any case with STEMI or a need of immediate PCI.</p> <p>Conclusions</p> <p>Our ANN had an excellent ability to predict STEMI and the need of acute PCI in ambulance ECGs, and has a potential to safely reduce the number of ECG transmitted to the CCU by almost two thirds.</p

    Common carotid segmentation in 18F-sodium fluoride PET/CT scans: Head-to-head comparison of artificial intelligence-based and manual method

    Get PDF
    Background: Carotid atherosclerosis is a major cause of stroke, traditionally diagnosed late. Positron emission tomography/computed tomography (PET/CT) with 18F-sodium fluoride (NaF) detects arterial wall micro-calcification long before macro-calcification becomes detectable by ultrasound, CT or magnetic resonance imaging. However, manual PET/CT processing is time-consuming and requires experience. We compared a convolutional neural network (CNN) approach with manual segmentation of the common carotids. Methods: Segmentation in NaF-PET/CT scans of 29 healthy volunteers and 20 angina pectoris patients were compared for segmented volume (Vol) and mean, maximal, and total standardized uptake values (SUVmean, SUVmax, and\ua0SUVtotal). SUVmean was the average of SUVmeans within the VOI, SUVmax the highest SUV in all voxels in the VOI, and SUVtotal the SUVmean multiplied by the Vol of the VOI. Intra\ua0and Interobserver variability with manual segmentation was examined in 25 randomly selected scans. Results: Bias for Vol, SUVmean, SUVmax, and SUVtotal were 1.33 \ub1 2.06, −0.01 \ub1 0.05, 0.09 \ub1 0.48, and 1.18 \ub1 1.99 in the left and 1.89 \ub1 1.5, −0.07 \ub1 0.12, 0.05 \ub1 0.47, and 1.61 \ub1 1.47, respectively, in the right common carotid artery. Manual segmentation lasted typically 20 min versus 1 min with the CNN-based approach. Mean Vol deviation at repeat manual segmentation was 14% and 27% in left and right common carotids. Conclusions: CNN-based segmentation was much faster and provided SUVmean values virtually identical to manually obtained ones, suggesting CNN-based analysis as a promising substitute of slow and cumbersome manual processing

    PET/CT imaging of spinal inflammation and microcalcification in patients with low back pain: A pilot study on the quantification by artificial intelligence-based segmentation

    Get PDF
    Background: Current imaging modalities are often incapable of identifying nociceptive sources of low back pain (LBP). We aimed to characterize these by means of positron emission tomography/computed tomography (PET/CT) of the lumbar spine region applying tracers 18F-fluorodeoxyglucose (FDG) and 18F-sodium fluoride (NaF) targeting inflammation and active microcalcification, respectively. Methods: Using artificial intelligence (AI)-based quantification, we compared PET findings in two sex- and age-matched groups, a case group of seven males and five females, mean age 45 \ub1 14 years, with ongoing LBP and a similar control group of 12 pain-free individuals. PET/CT scans were segmented into three distinct volumes of interest (VOIs): lumbar vertebral bodies, facet joints and intervertebral discs. Maximum, mean and total standardized uptake values (SUVmax, SUVmean and SUVtotal) for FDG and NaF uptake in the 3 VOIs were measured and compared between groups. Holm–Bonferroni correction was applied to adjust for multiple testing. Results: FDG uptake was slightly higher in most locations of the LBP group including higher SUVmean in the intervertebral discs (0.96 \ub1 0.34 vs. 0.69 \ub1 0.15). All NaF uptake values were higher in cases, including higher SUVmax in the intervertebral discs (11.63 \ub1 3.29 vs. 9.45 \ub1 1.32) and facet joints (14.98 \ub1 6.55 vs. 10.60 \ub1 2.97). Conclusion: Observed intergroup differences suggest acute inflammation and microcalcification as possible nociceptive causes of LBP. AI-based quantification of relevant lumbar VOIs in PET/CT scans of LBP patients and controls appears to be feasible. These promising, early findings warrant further investigation and confirmation

    Application of an artificial intelligence-based tool in [18F]FDG PET/CT for the assessment of bone marrow involvement in multiple myeloma

    Get PDF
    Purpose: [18F]FDG PET/CT is an imaging modality of high performance in multiple myeloma (MM). Nevertheless, the inter-observer reproducibility in PET/CT scan interpretation may be hampered by the different patterns of bone marrow (BM) infiltration in the disease. Although many approaches have been recently developed to address the issue of standardization, none can yet be considered a standard method in the interpretation of PET/CT. We herein aim to validate a novel three-dimensional deep learning-based tool on PET/CT images for automated assessment of the intensity of BM metabolism in MM patients. Materials and methods: Whole-body [18F]FDG PET/CT scans of 35 consecutive, previously untreated MM patients were studied. All patients were investigated in the context of an open-label, multicenter, randomized, active-controlled, phase 3 trial (GMMG-HD7). Qualitative (visual) analysis classified the PET/CT scans into three groups based on the presence and number of focal [18F]FDG-avid lesions as well as the degree of diffuse [18F]FDG uptake in the BM. The proposed automated method for BM metabolism assessment is based on an initial CT-based segmentation of the skeleton, its transfer to the SUV PET images, the subsequent application of different SUV thresholds, and refinement of the resulting regions using postprocessing. In the present analysis, six different SUV thresholds (Approaches 1–6) were applied for the definition of pathological tracer uptake in the skeleton [Approach 1: liver SUVmedian 7 1.1 (axial skeleton), gluteal muscles SUVmedian 7 4 (extremities). Approach 2: liver SUVmedian 7 1.5 (axial skeleton), gluteal muscles SUVmedian 7 4 (extremities). Approach 3: liver SUVmedian 7 2 (axial skeleton), gluteal muscles SUVmedian 7 4 (extremities). Approach 4: ≥ 2.5. Approach 5: ≥ 2.5 (axial skeleton), ≥ 2.0 (extremities). Approach 6: SUVmax liver]. Using the resulting masks, subsequent calculations of the whole-body metabolic tumor volume (MTV) and total lesion glycolysis (TLG) in each patient were performed. A correlation analysis was performed between the automated PET values and the results of the visual PET/CT analysis as well as the histopathological, cytogenetical, and clinical data of the patients. Results: BM segmentation and calculation of MTV and TLG after the application of the deep learning tool were feasible in all patients. A significant positive correlation (p &lt; 0.05) was observed between the results of the visual analysis of the PET/CT scans for the three patient groups and the MTV and TLG values after the employment of all six [18F]FDG uptake thresholds. In addition, there were significant differences between the three patient groups with regard to their MTV and TLG values for all applied thresholds of pathological tracer uptake. Furthermore, we could demonstrate a significant, moderate, positive correlation of BM plasma cell infiltration and plasma levels of β2-microglobulin with the automated quantitative PET/CT parameters MTV and TLG after utilization of Approaches 1, 2, 4, and 5. Conclusions: The automated, volumetric, whole-body PET/CT assessment of the BM metabolic activity in MM is feasible with the herein applied method and correlates with clinically relevant parameters in the disease. This methodology offers a potentially reliable tool in the direction of optimization and standardization of PET/CT interpretation in MM. Based on the present promising findings, the deep learning-based approach will be further evaluated in future prospective studies with larger patient cohorts
    • …
    corecore