662 research outputs found

    Tolerance Sensitivity Analysis and Robust Optimal Design Method of a Surface-Mounted Permanent Magnet Motor by Using a Hybrid Response Surface Method Considering Manufacturing Tolerances

    Full text link
    This paper presents a robust optimal design method using a hybrid response surface method (H-RSM) which directly finds an optimal point satisfying a target Z-value or a probability of failure. Through three steps, this paper achieves the goal that is to increase the open-circuit airgap flux (OCAF) in a surface-mounted permanent magnet motor and decrease its variation caused by variations of the airgap lengths including an additional one between permanent magnets and rotor back yoke. First, the OCAF equation is derived from the magnetic equivalent circuit (MEC) considering the additional airgap. Then, the equation is validated by comparing its results with those of the finite element method (FEM) modeled by the slotless stator. Next, the tolerance sensitivity analysis, using the partial derivative of the OCAF equation with respect to the airgap length, is performed to investigate the effects of design variables on the OCAF. It is shown that increasing the magnet thickness is effective for both increasing mean of the OCAF and reducing its variation. Finally, robust optimal design is performed using the H-RSM, in which all data are obtained from the FEM modeled by the slotted stator. The results of the robust optimal design are verified using the FEM

    Sensitivity Comparison of Open-Circuit Airgap Flux Between Surface-Mounted Permanent Magnet and Spoke-Type Permanent Magnet Machines Considering Manufacturing Tolerances

    Full text link
    The study compares the sensitivities of open-circuit airgap flux (OCAF) between a surface-mounted permanent magnet (SPM) machine and a spoke-type PM machine based on variations in airgap length including additional airgaps between permanent magnets and rotor core and between segmented stator cores to achieve high quality electric machines. Analytical equations deduced from magnetic equivalent circuits (MECs) are used to directly compare natural-born characteristics of the OCAF of the two machines. First, the MEC of each machine is modeled by considering two additional airgaps between the PMs and rotor core and between the segmented stator cores. Second, the OCAF equation of each machine is derived from the MEC to analyze the effects of the design variables on the OCAF. Subsequently, the partial derivative equation of the OCAF equation with respect to the airgap length is obtained for sensitivity analysis. A comparison of the equations of the two machines indicates that the spoke-type PM machine exhibits inherently higher sensitivity and average value of the OCAF when compared to that of the SPM machine. Finally, the results are validated via a two-dimensional finite element method (FEM) by considering the variations in airgap lengths

    Tensile Behavior and Cracking Pattern of an Ultra-High Performance Mortar Reinforced by Polyethylene Fiber

    Get PDF
    This paper presents an experimental study of the compressive strength, tensile behavior (including the tensile strength, tensile strain capacity, and toughness), and cracking patterns of an ultra-high performance mortar (UHPM) reinforced by polyethylene (PE) fiber as well as a discussion of the different tensile behaviors of the UHPM according to the types and contents of fibers used. The UHPM reinforced by microsteel fiber of 1.5 vol% and the UHPM reinforced by PE fibers with three different fiber contents were designed and prepared. A series of experiments was undertaken to assess the effect of PE fiber on the properties of the UHPM. The results found a lower strength level, higher tensile strain capacity and toughness, and a larger crack width in the PE fiber-reinforced UHPM compared to microsteel fiber-reinforced UHPM. It was also demonstrated that tensile strain capacity and toughness of 4.05% and 0.454 MPa m/m, respectively, can be attained when using the proposed polyethylene-fiber-reinforced UHPM

    Electroactive Artificial Muscles Based on Functionally Antagonistic Core–Shell Polymer Electrolyte Derived from PS-b-PSS Block Copolymer

    Get PDF
    Electroactive ionic soft actuators, a type of artificial muscles containing a polymer electrolyte membrane sandwiched between two electrodes, have been intensively investigated owing to their potential applications to bioinspired soft robotics, wearable electronics, and active biomedical devices. However, the design and synthesis of an efficient polymer electrolyte suitable for ion migration have been major challenges in developing high-performance ionic soft actuators. Herein, a highly bendable ionic soft actuator based on an unprecedented block copolymer is reported, i.e., polystyrene-b-poly(1-ethyl-3-methylimidazolium-4-styrenesulfonate) (PS-b-PSS-EMIm), with a functionally antagonistic core–shell architecture that is specifically designed as an ionic exchangeable polymer electrolyte. The corresponding actuator shows exceptionally good actuation performance, with a high displacement of 8.22 mm at an ultralow voltage of 0.5 V, a fast rise time of 5 s, and excellent durability over 14 000 cycles. It is envisaged that the development of this high-performance ionic soft actuator could contribute to the progress toward the realization of the aforementioned applications. Furthermore, the procedure described herein can also be applied for developing novel polymer electrolytes related to solid-state lithium batteries and fuel cells

    Consecutive Macular Edema and Visual Outcome in Branch Retinal Vein Occlusion

    Get PDF
    Purposes. The study introduced the concept of “consecutive macular edema” and evaluated the validity of visual outcome in macular edema (ME) secondary to branch retinal vein occlusion (BRVO). Methods. Patients were categorized into the gainer group and the nongainer group according to the final visual acuity. We analyzed clinical characteristics involving total and consecutive duration of ME between the two groups. Results. Among the total 71 eyes of 71 patients, intravitreal bevacizumab injection (26 patients), triamcinolone (21), and natural course (33) were enrolled. The consecutive duration of ME was shorter in the gainer group than in the nongainer group (3.33 ± 1.50 and 5.24 ± 2.39 months; P=0.000). After exclusion of macular ischemia, consecutive duration of ME in gainer group was also significantly shorter than in nongainer group (3.62 ± 1.60 and 6.11 ± 4.20 months; P=0.010). Conclusions. The duration of ME in the nongainer group was longer than in the gainer group. In particular, the consecutive duration was an important factor in determining the final visual outcome. Clinical Trial Registration. Approval by Hallym University Sacred Heart Hospital Institutional Review Board/Ethics Committee was obtained for this retrospective study

    Successful Treatment of Stereotactic Body Radiation Therapy Combined with Transarterial Chemolipiodolization for Hepatocellular Carcinoma with Biliary Obstruction

    Get PDF
    Conventional radiation therapy (RT) is a widely recognized treatment for hepatocellular carcinoma (HCC). However, conventional RT plays only a limited role in HCC treatment because of its low efficacy and the low tolerance of the liver for this modality. Stereotactic body radiation therapy (SBRT) was recently developed and represents the most advanced radiation therapy technique currently available. It can deliver a high dose in a short time to well-defined hepatic tumors, with rapid dose fall-off gradients. We believe that SBRT with transarterial chemolipiodolization (TACL) may prove promising as a combined treatment modality for HCC due to its precision and relative safety. Here we present a case of successful treatment of advanced HCC with obstructive jaundice using this combined modality

    Delayed Diagnosis of an Intraurethral Foreign Body Causing Urosepsis and Penile Necrosis

    Get PDF
    Cases of self-inserted foreign bodies in the male urethra and urinary bladder are unusual. In most cases, the type of foreign body can be identified by taking a history or from radiological findings; sometimes, however, it is difficult to identify the foreign body because of decreased mental capacity of the patient or unknown radiological characteristics of the foreign body. We experienced a chronic alcoholic patient with septicemia and penile necrosis in whom a fragment of mirror glass had passed through the urethra into the bladder. The glass, 2 cm in length and 0.7 cm in diameter, was detected by cystoscopy and was removed by using a resectosope
    • …
    corecore