39 research outputs found

    Dynamic plate osteosynthesis for fracture stabilization: how to do it

    Get PDF
    Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent tibial and femoral fractures with not fully closed growth plates. Although many lower limb shaft fractures are managed successfully with intramedullary nails, there are some important advantages of open-reduction-and-plate fixation: the risk of malalignment, anterior knee pain, or nonunion seems to be lower. The surgeon performing a plate osteosynthesis has the possibility to influence fixation strength and micromotion at the fracture gap. Long plates and oblique screws at the plate ends increase fixation strength. However, the number of screws does influence stiffness and stability. Lag screws and screws close to the fracture site reduce micromotion dramatically

    The interaction between the vastus medialis and vastus intermedius and its influence on the extensor apparatus of the knee joint

    Get PDF
    Although the vastus medialis (VM) is closely associated with the vastus intermedius (VI), there is a lack of data regarding their functional relationship. The purpose of this study was to investigate the anatomical interaction between the VM and VI with regard to their origins, insertions, innervation and function within the extensor apparatus of the knee joint.Methods: Eighteen human cadaveric lower limbs were investigated using macro-dissection techniques. Six limbs were cut transversely in the middle third of the thigh. The mode of origin, insertion and nerve supply of the extensor apparatus of the knee joint were studied. The architecture of the VM and VI was examined in detail, as was their anatomical interaction and connective tissue linkage to the adjacent anatomical structures.Results: The VM originated medially from a broad hammock-like structure. The attachment site of the VM always spanned over a long distance between: (1) patella, (2) rectus femoris tendon and (3) aponeurosis of the VI, with the insertion into the VI being the largest. VM units were inserted twice—once on the anterior and once on the posterior side of the VI. The VI consists of a complex multi- layered structure. The layers of the medial VI aponeurosis fused with the aponeuroses of the tensor vastus intermedius and vastus lateralis. Together, they form the two- layered intermediate layer of the quadriceps tendon. The VM and medial parts of the VI were innervated by the same medial division of the femoral nerve.Conclusion: The VM consists of multiple muscle units inserting into the entire VI. Together, they build a potential functional muscular complex. Therefore, the VM acts as an indirect extensor of the knee joint regulating and adjusting the length of the extensor apparatus throughout the entire range of motion. It is of clinical importance that, besides the VM, substantial parts of the VI directly contribute to the medial pull on the patella and help to maintain medial tracking of the patella during knee extension. The interaction between the VM and VI, with responsibility for the extension of the knee joint and influence on the patellofemoral function, leads readily to an understanding of common clinical problems found at the knee joint as it attempts to meet contradictory demands for both mobility and stability. Surgery or trauma in the anteromedial aspect of the quadriceps muscle group might alter a delicate interplay between the VM and VI. This would affect the extensor apparatus as a whole

    Recurrent hemarthrosis after total knee arthroplasty

    Get PDF
    This report describes a case of spontaneous recurrent hemarthrosis of the knee that presented 4 weeks after total knee arthroplasty. Femoral arteriography showed a false aneurysm of a branch of the inferior lateral geniculate artery. Therapeutic embolization of the arterial branch was performed using three platinum coils with good clinical result and good knee joint function. Hemarthrosis has not recurred since embolization

    Limitations of the vastus lateralis muscle as a substitute for lost abductor muscle function: an anatomical study

    Full text link
    Abductor insufficiency after hip arthroplasty resulting from an impaired gluteus medius and minimus remains an unsolved problem in orthopaedic surgery. The vastus lateralis (VL) was described as a functional substitute for abductor insufficiency in 2004. We carried out a macrodissection of twelve cadaveric hemipelvises to investigate the innervation of the VL and adjacent muscles to assess the extent the VL can be safely transferred. Results showed that direct muscle branches to proximal portions of the VL are too short to allow a significant shift; the shift may be as small as 13 mm. Nerves that supply the VL also extend to the vastus intermedius. This innervation pattern makes it impossible to shift the VL significantly without damaging branches to both

    Erratum: Tibiofemoral force following total knee arthroplasty: Comparison of four prosthesis designs in vitro

    No full text
    The authors have inadvertently left out several acknowledgments and wish to add them hereThis study was supported by DePuy International, the University of Western Australia, the Fremantle Hospital, and Mrs. Huggler.We would like to thank Dr. Hilaire Jacob for his help with the development of the mini-force platform.We would also like to thank the Australian Orthopaedic Association (AOA) for the financial support of Dr. Jeffcote

    Exercise Recommendations After Total Joint Replacement

    No full text
    corecore