63 research outputs found

    Study of dynamics of charge trapping in a-Si:H/SiN TFTs

    Get PDF
    In this paper we present the study of the failure mechanism responsible for long-term degradation that ultimately leads to instability in a-Si:H/SiN TFTs. The experimental data points we obtain by monitoring in-situ the drain current during gate bias stress (forward and reverse bias) and relaxation could not be fitted with the models existent in the literature. A new model that we have christened "Progressive Degradation Model" (PDM) emerged. The model makes use of Heimann-Warfield theory of trapping/detrapping front. PDM achieves a consistent fit to any bias condition showing that the degradation can be modelled quantitatively yielding the number of traps involved, their position and the charge dispersion coefficient. According to PDM the degradation of electrical response is a combined effect of a fast interface traps generation and a slow charge trapping at the created defect sites in a-SiN:H transitional region

    The influence of additives on the current carrying capacity of bulk YBa2Cu3OX

    Get PDF
    We studied the influence of using different powders and several additives on the shaping process and critical current density of sintered bulk YBa2Cu3OX. It was found that all additives used facilitated the shaping process. Silver and most organic additives influenced the critical current density only little, Zinc reduced it to zero, but an ethylenebisstearoylamide compound doubled the critical current density as compared to samples without additives

    Time dependent critical state in disks and rings

    Full text link

    Measurement of RudsR_{\text{uds}} and RR between 3.12 and 3.72 GeV at the KEDR detector

    Get PDF
    Using the KEDR detector at the VEPP-4M e+ee^+e^- collider, we have measured the values of RudsR_{\text{uds}} and RR at seven points of the center-of-mass energy between 3.12 and 3.72 GeV. The total achieved accuracy is about or better than 3.3%3.3\% at most of energy points with a systematic uncertainty of about 2.1%2.1\%. At the moment it is the most accurate measurement of R(s)R(s) in this energy range

    New precise determination of the \tau lepton mass at KEDR detector

    Full text link
    The status of the experiment on the precise τ\tau lepton mass measurement running at the VEPP-4M collider with the KEDR detector is reported. The mass value is evaluated from the τ+τ\tau^+\tau^- cross section behaviour around the production threshold. The preliminary result based on 6.7 pb1^{-1} of data is mτ=1776.800.23+0.25±0.15m_{\tau}=1776.80^{+0.25}_{-0.23} \pm 0.15 MeV. Using 0.8 pb1^{-1} of data collected at the ψ\psi' peak the preliminary result is also obtained: ΓeeBττ(ψ)=7.2±2.1\Gamma_{ee}B_{\tau\tau}(\psi') = 7.2 \pm 2.1 eV.Comment: 6 pages, 8 figures; The 9th International Workshop on Tau-Lepton Physics, Tau0

    Search for narrow resonances in e+ e- annihilation between 1.85 and 3.1 GeV with the KEDR Detector

    Full text link
    We report results of a search for narrow resonances in e+ e- annihilation at center-of-mass energies between 1.85 and 3.1 GeV performed with the KEDR detector at the VEPP-4M e+ e- collider. The upper limit on the leptonic width of a narrow resonance Gamma(R -> ee) Br(R -> hadr) < 120 eV has been obtained (at 90 % C.L.)

    Measurement of \Gamma_{ee}(J/\psi)*Br(J/\psi->e^+e^-) and \Gamma_{ee}(J/\psi)*Br(J/\psi->\mu^+\mu^-)

    Get PDF
    The products of the electron width of the J/\psi meson and the branching fraction of its decays to the lepton pairs were measured using data from the KEDR experiment at the VEPP-4M electron-positron collider. The results are \Gamma_{ee}(J/\psi)*Br(J/\psi->e^+e^-)=(0.3323\pm0.0064\pm0.0048) keV, \Gamma_{ee}(J/\psi)*Br(J/\psi->\mu^+\mu^-)=(0.3318\pm0.0052\pm0.0063) keV. Their combinations \Gamma_{ee}\times(\Gamma_{ee}+\Gamma_{\mu\mu})/\Gamma=(0.6641\pm0.0082\pm0.0100) keV, \Gamma_{ee}/\Gamma_{\mu\mu}=1.002\pm0.021\pm0.013 can be used to improve theaccuracy of the leptonic and full widths and test leptonic universality. Assuming e\mu universality and using the world average value of the lepton branching fraction, we also determine the leptonic \Gamma_{ll}=5.59\pm0.12 keV and total \Gamma=94.1\pm2.7 keV widths of the J/\psi meson.Comment: 7 pages, 6 figure

    Measurement of main parameters of the \psi(2S) resonance

    Get PDF
    A high-precision determination of the main parameters of the \psi(2S) resonance has been performed with the KEDR detector at the VEPP-4M e^{+}e^{-} collider in three scans of the \psi(2S) -- \psi(3770) energy range. Fitting the energy dependence of the multihadron cross section in the vicinity of the \psi(2S) we obtained the mass value M = 3686.114 +- 0.007 +- 0.011 ^{+0.002}_{-0.012} MeV and the product of the electron partial width by the branching fraction into hadrons \Gamma_{ee}*B_{h} = 2.233 +- 0.015 +- 0.037 +- 0.020 keV. The third error quoted is an estimate of the model dependence of the result due to assumptions on the interference effects in the cross section of the single-photon e^{+}e^{-} annihilation to hadrons explicitly considered in this work. Implicitly, the same assumptions were employed to obtain the charmonium leptonic width and the absolute branching fractions in many experiments. Using the result presented and the world average values of the electron and hadron branching fractions, one obtains the electron partial width and the total width of the \psi(2S): \Gamma_{ee} =2.282 +- 0.015 +- 0.038 +- 0.021 keV, \Gamma = 296 +- 2 +- 8 +- 3 keV. These results are consistent with and more than two times more precise than any of the previous experiments

    Status of NSLS-II booster

    No full text
    The National Synchrotron Light Source II is a third generation light source under construction at Brookhaven National Laboratory. The project includes a highly optimized 3 GeV electron storage ring, linac pre-injector and full-energy booster-synchrotron. Budker Institute of Nuclear Physics builds booster for NSLS-II. The booster should accelerate the electron beam continuously and reliably from minimal 170 MeV injection energy to maximal energy of 3.15 GeV and average beam current of 20 mA. The booster shall be capable of multi-bunch and single bunch operation. This paper summarizes the status of NSLS-II booster.Национальный источник синхротронного излучения II является синхротроном третьего поколения, созданным в Брукхевенской национальной лаборатории. Проект включает: высокооптимизированное накопительное кольцо на 3 ГэВ, линейный ускоритель и бустерный синхротрон на полную энергию. Институт ядерной физики им. Г.И. Будкера создает бустер для NSLS-II. Бустер должен надежно и непрерывно ускорять пучок электронов от минимальной энергии инжекции 170 МэВ до максимальной энергии 3,15 ГэВ с током пучка 20 мА. Бустер должен быть способен работать в односгустковом и многосгустковом режимах. Эта статья суммирует состояние дел по бустеру для NSLS-II.Національне джерело синхротронного випромінювання II є синхротроном третього покоління, створеним у Брукхевенській національній лабораторії. Проект включає: високооптимізоване накопичувальне кільце на 3 ГеВ, лінійний прискорювач і бустерний синхротрон на повну енергію. Інститут ядерної фізики ім. Г.І. Будкера створює бустер для NSLS-II. Бустер повинен надійно і безперервно прискорювати пучок електронів від мінімальної енергії інжекції 170 МеВ до максимальної енергії 3,15 ГеВ зі струмом пучка 20 мА. Бустер повинен бути здатний працювати в односгустковому і багатосгустковому режимах. Ця стаття підсумовує стан справ по бустеру для NSLS-II
    corecore