283 research outputs found

    Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.

    Get PDF
    PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA

    Economic and Health Value of Delaying Atrial Fibrillation Progression Using Radiofrequency Catheter Ablation

    Get PDF
    Background: Radiofrequency catheter ablation (RFCA) is an established treatment for atrial fibrillation (AF) refractory to antiarrhythmic drugs. The economic value of RFCA in delaying disease progression has not been quantified. Methods: An individual-level, state-transition health economic model estimated the impact of delayed AF progression using RFCA versus antiarrhythmic drug treatment for a hypothetical sample of patients with paroxysmal AF. The model incorporated the lifetime risk of progression from paroxysmal AF to persistent AF, informed by data from the ATTEST (Atrial Fibrillation Progression Trial). The incremental effect of RFCA on disease progression was modeled over a 5-year duration. Annual crossover rates were also included for patients in the antiarrhythmic drug group to mirror clinical practice. Estimates of discounted costs and quality-adjusted life years asssociated with health care utilization, clinical outcomes, and complications were projected over patients' lifetimes. Results: From the payer's perspective, RFCA was superior to antiarrhythmic drug treatment with an estimated mean net monetary benefit per patient of 8516(8516 (148-16681),drivenbyreducedhealthcareutilization,cost,andimprovedqualityadjustedlifeyears.RFCAreducedmean(9516 681), driven by reduced health care utilization, cost, and improved quality-adjusted life years. RFCA reduced mean (95% CI) per-patient costs by 73 (-2700to2700 to 2200), increased mean quality-adjusted life years by 0.084 (0.0-0.17) and decreased the mean number of cardiovascular-related health care encounters by 24%. Conclusions: RFCA is a dominant (less costly and more effective) treatment strategy for patients with AF, especially those with early AF for whom RFCA could delay progression to advanced AF. Increased utilization of RFCA - particularly among patients earlier in their disease progression - may provide clinical and economic benefits

    Site of Accessory Pathway Block After Radiofrequency Catheter Ablation in Patients with the Wolff-Parkinson-White Syndrome

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73717/1/j.1540-8167.1994.tb01111.x.pd

    The Impact of Cryoballoon Versus Radiofrequency Ablation for Paroxysmal Atrial Fibrillation on Healthcare Utilization and Costs: An Economic Analysis From the FIRE AND ICE Trial

    Get PDF
    BACKGROUND: This study sought to assess payer costs following cryoballoon or radiofrequency current (RFC) catheter ablation of paroxysmal atrial fibrillation in the randomized FIRE AND ICE trial. METHODS AND RESULTS: A trial period analysis of healthcare costs evaluated the impact of ablation modality (cryoballoon versus RFC) on differences in resource use and associated payer costs. Analyses were based on repeat interventions, rehospitalizations, and cardioversions during the trial, with unit costs based on 3 national healthcare systems (Germany [euro], the United Kingdom [ pound], and the United States []).Totalpayercostswerecalculatedbyapplyingstandardunitcoststohospitalstays,usingInternationalClassificationofDiseases,10thRevisiondiagnosesandprocedurecodesthatweremappedtocountryspecificdiagnosisrelatedgroups.Patients(N=750)randomized1:1tocryoballoon(n=374)orRFC(n=376)ablationwerefollowedforameanof1.5years.ResourceusewaslowerinthecryoballoonthantheRFCgroup(205hospitalizationsand/orinterventionsin122patientsversus268eventsin154patients).Thecostdifferencesperpatientinmeantotalpayercostsduringfollowupwereeuro640,pound364,and]). Total payer costs were calculated by applying standard unit costs to hospital stays, using International Classification of Diseases, 10th Revision diagnoses and procedure codes that were mapped to country-specific diagnosis-related groups. Patients (N=750) randomized 1:1 to cryoballoon (n=374) or RFC (n=376) ablation were followed for a mean of 1.5 years. Resource use was lower in the cryoballoon than the RFC group (205 hospitalizations and/or interventions in 122 patients versus 268 events in 154 patients). The cost differences per patient in mean total payer costs during follow-up were euro640, pound364, and 925 in favor of cryoballoon ablation (P=0.012, 0.013, and 0.016, respectively). This resulted in trial period total cost savings of euro245 000, pound140 000, and $355 000. CONCLUSIONS: When compared with RFC ablation, cryoballoon ablation was associated with a reduction in resource use and payer costs. In all 3 national healthcare systems analyzed, this reduction resulted in substantial trial period cost savings, primarily attributable to fewer repeat ablations and a reduction in cardiovascular rehospitalizations with cryoballoon ablation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Identifier: NCT01490814

    Five-year outcome in 18 010 patients from the German Aortic Valve Registry

    Get PDF
    OBJECTIVES: To determine the 5-year outcome in patients treated by isolated transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (sAVR)—a prospective observational cohort study. METHODS: A total of 18 010 patients were included (n = 8942 TAVI and n = 9068 sAVR) in the German Aortic Valve Registry (GARY) who were treated in 2011 and 2012 at 92 sites in central Germany. Eligible patients with TAVI and sAVR were matched using propensity scores in a nearest-neighbour approach. Patients with repeat procedures or unequivocal indication for one treatment option (e.g. frailty) were excluded (n = 4785 for TAVI and n = 2 for sAVR). This led to 13 223 patients (4157 TAVI and 9066 sAVR) as an unmatched subcohort. The main outcome measure was the 5-year all-cause mortality. RESULTS: TAVI patients were significantly older (80.9 ± 6.1 vs 68.5 ± 11.1 years, P < 0.001), had a higher Society of Thoracic Surgeons (STS) score (6.3 ± 4.9 vs 2.6 ± 3.0, P < 0.001) and a higher 5-year all-cause mortality (49.8% vs 16.5%, P < 0.0001). There was no major difference in in-hospital stroke, in-hospital myocardial infarction, or temporary and chronic dialysis. In the propensity score-matched group (n = 3640), there were 763 deaths (41.9%) among 1820 TAVI patients compared with 552 (30.3%) among 1820 treated with sAVR during the 5-year follow-up (hazard ratio 1.51, 95% confidence interval 1.35–1.68; P < 0.0001). New pacemaker implantation was performed in 448 patients (24.6%) after TAVI and in 201 (11.0%) after sAVR (P < 0.0001). CONCLUSIONS: The 5-year follow-up data show that TAVI patients were significantly older and had a higher STS score than sAVR patients. After propensity score matching, TAVI with early-generation prosthesis was associated with significantly higher 5-year all-cause mortality than sAVR

    Improvements in 25 Years of Implantable Cardioverter Defibrillator Therapy

    Get PDF
    In 1980, Dr. Michel Mirowski and his team inserted the first implantable cardioverter defibrillator (ICD) in a patient. Initially, ICD therapy was not widely accepted, and many physicians actually considered this therapy unethical. Large secondary and primary prevention trials, demonstrating a beneficial effect of ICD therapy in selected patients not only on arrhythmic death but also on all-cause mortality, stimulated a rapid growth in the number of implants and increased patient’s and physician’s acceptance. Improvements in size and weight, arrhythmia discrimination capabilities, battery technology, shock waveform and output, monitoring capabilities and defibrillator electrode technology eventually resulted in the current large number of yearly implants. Today, almost 40 years after the conception of the ICD and 25 years after the first human implant, ICD therapy is the treatment of choice for patients at risk for life-threatening arrhythmias either as secondary or primary prevention. Furthermore, with the more recent addition of resynchronisation therapy to standard ICD therapy, it became possible to treat selected patients with advanced symptoms of heart failure and to lower the risk of sudden death

    HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation

    Get PDF
    During the past decade, catheter ablation of atrial fibrillation (AF) has evolved rapidly from a highly experimental unproven procedure, to its current status as a commonly performed ablation procedure in many major hospitals throughout the world. Surgical ablation of AF, using either standard or minimally invasive techniques, is also performed in many major hospitals throughout the world. The purpose of this Consensus Statement is to provide a state-of-the-art review of the field of catheter and surgical ablation of AF, and to report the findings of a Task Force, convened by the Heart Rhythm Society and charged with defining the indications, techniques, and outcomes of this procedure. The Heart Rhythm Society was pleased to develop this Consensus Statement in partnership with the European Heart Rhythm Association and the European Cardiac Arrhythmia Society. This statement summarizes the opinion of the Task Force members based on their own experience in treating patients, as well as a review of the literature, and is directed to all health care professionals who are involved in the care of patients with AF, particularly those who are undergoing or are being considered for catheter or surgical ablation procedures for AF. This statement is not intended to recommend or promote catheter ablation of AF. Rather the ultimate judgment regarding care of a particular patient must be made by the health care provider and patient in light of all the circumstances presented by that patient. In writing a "consensus" document, it is recognized that consensus does not mean that there was complete agreement among all Task Force members. We attempted to identify those aspects of AF ablation for which a true "consensus" could be identified ( Tables 1 and 2 ). Surveys of the entire Task Force were used to identify these areas of consensus. The main objective of this document is
    corecore