183 research outputs found

    Determination of the total width of the eta' meson

    Full text link
    Taking advantage of both the low-emittance proton-beam of the Cooler Synchrotron COSY and the high momentum precision of the COSY-11 detector system, the mass distribution of the eta' meson was measured with a resolution of 0.33 MeV/c^2 (FWHM), improving the experimental mass resolution by almost an order of magnitude with respect to previous results. Based on the sample of more than 2300 reconstructed pp --> pp eta' events the total width of the eta' meson was determined to be 0.226 +- 0.017(stat.) +- 0.014(syst.) MeV/c^2.Comment: 4 pages, 4 figure

    Isospin dependence of the eta prime meson production in nucleon-nucleon collisions

    Get PDF
    A comparison of the close-to-threshold total cross section for the eta prime production in pp --> pp eta prime and pn --> pn eta prime reactions constitutes a tool to investigate the eta prime meson structure and the reaction mechanism in the channels of isospin I=0 and I=1 and may provide insight into the flavour-singlet (perhaps also into gluonium) content of the eta prime meson. In this contribution we present preliminary results of measurement of the quasi-free production of the eta prime meson in the proton-neutron collisions conducted using the COSY-11 facility.Comment: Presented at 10th International Workshop on Meson Production, Properties and Interaction (MESON 2008), Cracow, Poland, 6 - 10 June 200

    System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector

    Get PDF
    Reconstruction of the image in Positron Emission Tomographs (PET) requires the knowledge of the system response kernel which describes the contribution of each pixel (voxel) to each tube of response (TOR). This is especially important in list-mode reconstruction systems, where an efficient analytical approximation of such function is required. In this contribution, we present a derivation of the system response kernel for a novel 2D strip PET.Comment: 10 pages, 2 figures; Presented at Symposium on applied nuclear physics and innovative technologies, Cracow, 03-06 June 201

    A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays

    Full text link
    All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. 22^{22}Na or 68^{68}Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present methods and it is well suited for newly developed TOF-PET scanners with a large longitudinal field of view. The method enables also monitoring of the quality of the scintillator materials and in general allows for the continuous quality assurance of the PET detector performance.Comment: 10 pages, 7 figure

    Application of Compressive Sensing Theory for the Reconstruction of Signals in Plastic Scintillators

    Get PDF
    Compressive Sensing theory says that it is possible to reconstruct a measured signal if an enough sparse representation of this signal exists in comparison to the number of random measurements. This theory was applied to reconstruct signals from measurements of plastic scintillators. Sparse representation of obtained signals was found using SVD transform.Comment: 7 pages, 3 figures; Presented at Symposium on applied nuclear physics and innovative technologies, Cracow, 03-06 June 201
    corecore