114 research outputs found

    Channel Blockade in a Two-Path Triple-Quantum-Dot System

    Get PDF
    Electronic transport through a two-path triple-quantum-dot system with two source leads and one drain is studied. By separating the conductance of the two double dot paths, we are able to observe double dot and triple dot physics in transport and study the interaction between the paths. We observe channel blockade as a result of inter-channel Coulomb interaction. The experimental results are understood with the help of a theoretical model which calculates the parameters of the system, the stability regions of each state and the full dynamical transport in the triple dot resonances.Comment: 6 pages, 6 figure

    Emittance Growth at LHC Injection from SPS and LHC Kicker Ripple

    Get PDF
    Fast pulsed kicker magnets are used to extract beams from the SPS and inject them into the LHC. The kickers exhibit time-varying structure in the pulse shape which translates into small offsets with respect to the closed orbit at LHC injection. The LHC damper systems will be used to damp out the resulting betatron oscillations, to keep the growth in the transverse emittance within specification. This paper describes the results of the measurements of the kicker ripple for the two systems, both in the laboratory and with beam, and presents the simulated performance of the transverse damper in terms of beam emittance growth. The implications for LHC operation are discussed

    Wirkung von Spreading Depression auf die intrazellulÀre AktivitÀt von Neuronen im Hirnschnitt der Maus

    Full text link
    Ziel der vorliegenden Untersuchung war es, die Wirkung von Spreading Depression (SD) auf die intrazellulĂ€re AktivitĂ€t von Neuronen zu analysieren. Die Untersuchungen wurden an kombinierten Amygdala-Hippocampus-Cortex-SchnittprĂ€paraten der Maus durchgefĂŒhrt. SD wurde durch Applikation von 3M KCl induziert. Die Parameter der einzelnen Neurone des Hippocampus, der lateralen Amygdala (LA) und des Neocortex und das Feldpotential wurden mit Hilfe von Mikroelektroden abgeleitet. Es wurde bewiesen, dass SD die intrazellulĂ€ren Charakteristika im Neocortex direkt beeinflusst und indirekt ĂŒber synaptische Weiterleitung die AktivitĂ€t im Hippocampus und in der LA verstĂ€rkt. Zusammenstellend lĂ€sst sich sagen, dass die Ergebnisse die komplexe Wirkung von SD auf die neuronale AktivitĂ€t darstellen und im Zusammenhang mit den synaptischen VerĂ€nderungen nach SD stehen, sowie eine wichtige Rolle in der Pathophysiologie der SD-bezogenen neurologischen Erkrankungen, wie MigrĂ€ne und Epilepsie, spielen

    LHC Transverse Feedback System: First Results of Commissionning

    Get PDF
    A powerful transverse feedback system ("Damper") has been installed in LHC. It will stabilise the high intensity beam against coupled bunch transverse instabilities in a frequency range from 3 kHz to 20 MHz and at the same time damp injection oscillations originating from steering errors and injection kicker ripple. The LHC Damper can also be used as means of exciting transverse oscillations for the purposes of abort gap cleaning and tune measurement. The LHC Damper includes 4 feedback systems on 2 circulating beams (in other words one feedback system per beam and plane). Every feedback system consists of 4 electrostatic kickers, 4 push-pull wide band power amplifiers, 8 preamplifiers, two digital processing units and 2 beam position monitors with low-level electronics. The power and low-level subsystem layout is described along with first results from the commissioning of 16 power amplifiers and 16 electrostatic kickers located in the LHC tunnel. The achieved performance is compared with earlier predictions and requirements for injection damping and instability control. Requirements and first measurements of the performance of the power and low-level subsystems are summarized

    LHC Transverse Feedback System and its Hardware Commissioning

    Get PDF
    A powerful transverse feedback system ("Damper") has been installed in LHC. It will stabilise coupled bunch instabilities in a frequency range from 3 kHz to 20 MHz and at the same time damp injection oscillations originating from steering errors and injection kicker ripple. The transverse damper can also be used as an exciter for purposes of abort gap cleaning or tune measurement. The power and lowlevel systems layouts are described along with results from the hardware commissioning. The achieved performance is compared with earlier predictions and requirements for injection damping and instability control

    Highly Sensitive Determination of Hydrogen Peroxide and Glucose by Fluorescence Correlation Spectroscopy

    Get PDF
    BACKGROUND: Because H(2)O(2) is generated by various oxidase-catalyzed reactions, a highly sensitive determination method of H(2)O(2) is applicable to measurements of low levels of various oxidases and their substrates such as glucose, lactate, glutamate, urate, xanthine, choline, cholesterol and NADPH. We propose herein a new, highly sensitive method for the measurement of H(2)O(2) and glucose using fluorescence correlation spectroscopy (FCS). METHODOLOGY/PRINCIPAL FINDINGS: FCS has the advantage of allowing us to determine the number of fluorescent molecules. FCS measures the fluctuations in fluorescence intensity caused by fluorescent probe movement in a small light cavity with a defined volume generated by confocal illumination. We thus developed a highly sensitive determination system of H(2)O(2) by FCS, where horseradish peroxidase (HRP) catalyzes the formation of a covalent bond between fluorescent molecules and proteins in the presence of H(2)O(2). Our developed system gave a linear calibration curve for H(2)O(2) in the range of 28 to 300 nM with the detection limit of 8 nM. In addition, by coupling with glucose oxidase (GOD)-catalyzed reaction, the method allows to measure glucose in the range of 80 nM to 1.5 ”M with detection limit of 24 nM. The method was applicable to the assay of glucose in blood plasma. The mean concentration of glucose in normal human blood plasma was determined to be 4.9 mM. CONCLUSIONS/SIGNIFICANCE: In comparison with commercial available methods, the detection limit and the minimum value of determination for glucose are at least 2 orders of magnitude more sensitive in our system. Such a highly sensitive method leads the fact that only a very small amount of plasma (20 nL) is needed for the determination of glucose concentration in blood plasma

    Fostering support for non-democratic rule? Controlled political liberalization and popular support for non-democratic regimes

    Full text link
    When the Cold War ended, many non-democratic regimes across the globe embarked on a course of controlled political liberalization, hoping to stabilize their autocratic rule by mitigating popular demands for democratization and increasing regime legitimacy. But does this strategy actually work? This article uses multi-level analyses to examine how the degree of political liberalization affects regime support in non-democratic political systems and to ascertain which mechanisms underlie this effect. Drawing on aggregate measures of political liberalization and comparative survey data from four regional survey projects and 31 non-democracies, the study's results indicate that the degree of liberalization has no decisively positive effect on regime support, suggesting controlled political liberalization might not be an effective legitimizing strategy after all.Nach Ende des Kalten Krieges haben viele nicht-demokratische Regime weltweit einen Kurs der begrenzten politischen Öffnung eingeschlagen, um öffentliche Forderungen nach Demokratisierung zu entschĂ€rfen und auf diese Weise die LegitimitĂ€t ihrer autokratischen Herrschaft zu erhöhen. Doch ist diese Strategie tatsĂ€chlich effektiv? Der Beitrag verwendet Mehrebenenanalysen, um zu untersuchen wie der Grad an politischer Öffnung die RegimerunterstĂŒtzung in nicht-demokratischen politischen Systemen beeinflusst. Auf Basis von Aggregatmaßen zur politischen Öffnung und Individualdaten aus vier regionalen Umfrageprojekten und 31 Autokratien kann kein klarer positiver Effekt des Grads der politischen Öffnung auf die RegimeunterstĂŒtzung nachgewiesen werden, was eine begrenzte politische Öffnung als wenig effektive Legitimationsstrategie erscheinen lĂ€sst

    Sarcosine oxidase composite screen-printed electrode for sarcosine determination in biological samples

    Get PDF
    As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples
    • 

    corecore