4,368 research outputs found

    Black Hole Relics in Large Extra Dimensions

    Get PDF
    Recent calculations applying statistical mechanics indicate that under the assumption of compactified large extra dimensions a black hole might evolve into a (quasi-)stable state with mass close to the new fundamental scale MfM_f. Black holes and therefore their relics might be produced at the {\sc LHC} in the case of extra-dimensional topologies. In this energy regime, Hawking's evaporation scenario is modified due to energy conservation and quantum effects. We reanalyse the evaporation of small black holes including the quantisation of the emitted radiation due to the finite surface of the black hole. It is found that observable stable black hole relics with masses ∼1−3Mf\sim 1-3 M_f are formed which can be identified by a delayed single jet with a corresponding hard momentum kick to the relic and by ionisation, e.g. in a TPC

    Search for TeV γ\gamma -rays from H1426+428 during 2004-07 with the TACTIC telescope

    Get PDF
    The BL Lac object H1426+428 (z≡0.129z\equiv 0.129) is an established source of TeV γ\gamma-rays and detections of these photons from this object also have important implications for estimating the Extragalactic Background Light (EBL) in addition to the understanding of the particle acceleration and γ\gamma-ray production mechanisms in the AGN jets. We have observed this source for about 244h in 2004, 2006 and 2007 with the TACTIC γ\gamma-ray telescope located at Mt. Abu, India. Detailed analysis of these data do not indicate the presence of any statistically significant TeV γ\gamma-ray signal from the source direction. Accordingly, we have placed an upper limit of ≤1.18×10−12\leq1.18\times10^{-12} photonsphotons cm−2cm^{-2} s−1s^{-1} on the integrated γ\gamma-ray flux at 3σ\sigma significance level.Comment: 11 pages, 5 figures accepted for publication in Journal of Physics G: Nuclear and Particle Physic

    Very High Energy gamma-ray observations of Mrk 501 using TACTIC imaging gamma-ray telescope during 2005-06

    Full text link
    In this paper we report on the Markarian 501 results obtained during our TeV γ\gamma-ray observations from March 11 to May 12, 2005 and February 28 to May 7, 2006 for 112.5 hours with the TACTIC γ\gamma-ray telescope. During 2005 observations for 45.7 hours, the source was found to be in a low state and we have placed an upper limit of 4.62 ×\times 10−12^{-12} photons cm−2^{-2} s−1^{-1} at 3σ\sigma level on the integrated TeV γ\gamma-ray flux above 1 TeV from the source direction. However, during the 2006 observations for 66.8h, detailed data analysis revealed the presence of a TeV γ\gamma-ray signal from the source with a statistical significance of 7.5σ\sigma above Eγ≥E_{\gamma}\geq 1 TeV. The time averaged differential energy spectrum of the source in the energy range 1-11 TeV is found to match well with the power law function of the form (dΦ/dE=f0E−Γd\Phi/dE=f_0 E^{-\Gamma}) with f0=(1.66±0.52)×10−11cm−2s−1TeV−1f_0=(1.66\pm0.52)\times 10^{-11}cm^{-2}s^{-1}TeV^{-1} and Γ=2.80±0.27\Gamma=2.80\pm0.27.Comment: 16 pages and 8 Figures Accepted for publication in the Journal of Physics

    Data processing model for the CDF experiment

    Get PDF
    The data processing model for the CDF experiment is described. Data processing reconstructs events from parallel data streams taken with different combinations of physics event triggers and further splits the events into datasets of specialized physics datasets. The design of the processing control system faces strict requirements on bookkeeping records, which trace the status of data files and event contents during processing and storage. The computing architecture was updated to meet the mass data flow of the Run II data collection, recently upgraded to a maximum rate of 40 MByte/sec. The data processing facility consists of a large cluster of Linux computers with data movement managed by the CDF data handling system to a multi-petaByte Enstore tape library. The latest processing cycle has achieved a stable speed of 35 MByte/sec (3 TByte/day). It can be readily scaled by increasing CPU and data-handling capacity as required.Comment: 12 pages, 10 figures, submitted to IEEE-TN

    Observations of TeV gamma-rays from Mrk 421 during Dec. 2005 to Apr. 2006 with the TACTIC telescope

    Full text link
    The TACTIC γ\gamma-ray telescope has observed Mrk 421 on 66 clear nights from Dec. 07, 2005 to Apr. 30, 2006, totalling ∼\sim 202 hours of on-source observations. Here, we report the detection of flaring activity from the source at ≥\geq 1 TeV energy and the time-averaged differential γ\gamma-ray spectrum in the energy range 1-11 TeV for the data taken between Dec. 27, 2005 to Feb. 07, 2006 when the source was in a relatively higher state as compared to the rest of the observation period. Analysis of this data spell, comprising about ∼\sim97h reveals the presence of a ∼12.0σ\sim 12.0 \sigma γ\gamma-ray signal with daily flux of >> 1 Crab unit on several days. A pure power law spectrum with exponent −3.11±0.11-3.11\pm0.11 as well as a power law spectrum with an exponential cutoff (Γ=−2.51±0.26(\Gamma = -2.51\pm0.26 and E0=(4.7±2.1)TeV)E_0=(4.7\pm2.1) TeV) are found to provide reasonable fits to the inferred differential spectrum within statistical uncertainties. We believe that the TeV light curve presented here, for nearly 5 months of extensive coverage, as well as the spectral information at γ\gamma-ray energies of >> 5 TeV provide a useful input for other groups working in the field of γ\gamma-ray astronomy.Comment: 13pages,4figures; Accepted for publication in Astroparticle Physic

    Multifaceted intervention to reduce haemodialysis catheter related bloodstream infections: REDUCCTION stepped wedge, cluster randomised trial.

    Get PDF
    OBJECTIVE: To identify whether multifaceted interventions, or care bundles, reduce catheter related bloodstream infections (CRBSIs) from central venous catheters used for haemodialysis. DESIGN: Stepped wedge, cluster randomised design. SETTING: 37 renal services across Australia. PARTICIPANTS: All adults (age ≥18 years) under the care of a renal service who required insertion of a new haemodialysis catheter. INTERVENTIONS: After a baseline observational phase, a service-wide, multifaceted intervention bundle that included elements of catheter care (insertion, maintenance, and removal) was implemented at one of three randomly assigned time points (12 at the first time point, 12 at the second, and 13 at the third) between 20 December 2016 and 31 March 2020. MAIN OUTCOMES MEASURE: The primary endpoint was the rate of CRBSI in the baseline phase compared with intervention phase at the renal service level using the intention-to-treat principle. RESULTS: 1.14 million haemodialysis catheter days of use were monitored across 6364 patients. Patient characteristics were similar across baseline and intervention phases. 315 CRBSIs occurred (158 in the baseline phase and 157 in the intervention phase), with a rate of 0.21 per 1000 days of catheter use in the baseline phase and 0.29 per 1000 days in the intervention phase, giving an incidence rate ratio of 1.37 (95% confidence interval 0.85 to 2.21; P=0.20). This translates to one in 10 patients who undergo dialysis for a year with a catheter experiencing an episode of CRBSI. CONCLUSIONS: Among patients who require a haemodialysis catheter, the implementation of a multifaceted intervention did not reduce the rate of CRBSI. Multifaceted interventions to prevent CRBSI might not be effective in clinical practice settings. TRIAL REGISTRATION: Australia New Zealand Clinical Trials Registry ACTRN12616000830493

    Physics at Future Hadron Colliders

    Get PDF
    We discuss the physics opportunities and detector challenges at future hadron colliders. As guidelines for energies and luminosities we use the proposed luminosity and/or energy upgrade of the LHC (SLHC), and the Fermilab design of a Very Large Hadron Collider (VLHC). We illustrate the physics capabilities of future hadron colliders for a variety of new physics scenarios (supersymmetry, strong electroweak symmetry breaking, new gauge bosons, compositeness and extra dimensions). We also investigate the prospects of doing precision Higgs physics studies at such a machine, and list selected Standard Model physics rates
    • …
    corecore