122 research outputs found

    Scalar Differential Equation for Slowly-Varying Thickness-Shear Modes in AT-Cut Quartz Resonators With Surface Impedance for Acoustic Wave Sensor Application

    Get PDF
    For time-harmonic motions, we generalize a 2-D scalar differential equation derived previously by Tiersten for slowly-varying thickness-shear vibrations of AT-cut quartz resonators. The purpose of the generalization is to include the effects of surface acoustic impedance from, e.g., mass layers or fluids for sensor applications. In addition to the variation of fields along the plate thickness, which is considered in the usual 1-D acoustic wave sensor models, the equation obtained also describes in-plane variations of the fields, and therefore can be used to study the vibrations of finite plate sensors with edge effects. The equation is compared with the theory of piezoelectricity in the special cases of acoustic waves and pure thickness vibrations in unbounded plates. An example of a finite rectangular plate is also given

    Scalar Differential Equation for Slowly-Varying Thickness-Shear Modes in AT-Cut Quartz Resonators with Surface Impedance for Acoustic Wave Sensor Application

    Get PDF
    For time-harmonic motions, we generalize a 2-D scalar differential equation derived previously by Tiersten for slowly-varying thickness-shear vibrations of AT-cut quartz resonators. The purpose of the generalization is to include the effects of surface acoustic impedance from, e.g., mass layers or fluids for sensor applications. In addition to the variation of fields along the plate thickness, which is considered in the usual 1-D acoustic wave sensor models, the equation obtained also describes in-plane variations of the fields, and therefore can be used to study the vibrations of finite plate sensors with edge effects. The equation is compared with the theory of piezoelectricity in the special cases of acoustic waves and pure thickness vibrations in unbounded plates. An example of a finite rectangular plate is also given

    Clinical Practice Guidelines for Recall and Maintenance of Patients with Tooth-Borne and Implant-Borne Dental Restorations

    Get PDF
    Purpose To provide guidelines for patient recall regimen, professional maintenance regimen, and at-home maintenance regimen for patients with tooth-borne and implant-borne removable and fixed restorations. Materials and Methods The American College of Prosthodontists (ACP) convened a scientific panel of experts appointed by the ACP, American Dental Association (ADA), Academy of General Dentistry (AGD), and American Dental Hygienists Association (ADHA) who critically evaluated and debated recently published findings from two systematic reviews on this topic. The major outcomes and consequences considered during formulation of the clinical practice guidelines (CPGs) were risk for failure of tooth- and implant-borne restorations. The panel conducted a round table discussion of the proposed guidelines, which were debated in detail. Feedback was used to supplement and refine the proposed guidelines, and consensus was attained. Results A set of CPGs was developed for tooth-borne restorations and implant-borne restorations. Each CPG comprised (1) patient recall, (2) professional maintenance, and (3) at-home maintenance. For tooth-borne restorations, the professional maintenance and at-home maintenance CPGs were subdivided for removable and fixed restorations. For implant-borne restorations, the professional maintenance CPGs were subdivided for removable and fixed restorations and further divided into biological maintenance and mechanical maintenance for each type of restoration. The at-home maintenance CPGs were subdivided for removable and fixed restorations. Conclusions The clinical practice guidelines presented in this document were initially developed using the two systematic reviews. Additional guidelines were developed using expert opinion and consensus, which included discussion of the best clinical practices, clinical feasibility, and risk-benefit ratio to the patient. To the authors’ knowledge, these are the first CPGs addressing patient recall regimen, professional maintenance regimen, and at-home maintenance regimen for patients with tooth-borne and implant-borne restorations. This document serves as a baseline with the expectation of future modifications when additional evidence becomes available

    A Systematic Review of Recall Regimen and Maintenance Regimen of Patients with Dental Restorations. Part 2: Implant-Borne Restorations

    Get PDF
    Purpose To evaluate the current scientific evidence on patient recall and maintenance of implant-supported restorations, to standardize patient care regimens and improve maintenance of oral health. An additional purpose was to examine areas of deficiency in the current scientific literature and provide recommendations for future studies. Materials and Methods An electronic search for articles in the English language literature from the past 10 years was performed independently by multiple investigators using a systematic search process. After application of predetermined inclusion and exclusion criteria, the final list of articles was reviewed to meet the objectives of this review. Results The initial electronic search resulted in 2816 titles. The systematic application of inclusion and exclusion criteria resulted in 14 articles that satisfied the study objectives. An additional 6 articles were added through a supplemental search process for a total of 20 studies. Of these, 11 were randomized controlled clinical trials, and 9 were observational studies. The majority of the studies (15 out of 20) were conducted in the past 5 years and most studies were conducted in Europe (15), followed by Asia (2), South America (1), the United States (1), and the Middle East (1). Results from the qualitative data on a combined 1088 patients indicated that outcome improvements in recall and maintenance regimen were related to (1) patient/treatment characteristic (type of prosthesis, type of prosthetic components, and type of restorative materials); (2) specific oral topical agents or oral hygiene aids (electric toothbrush, interdental brush, chlorhexidine, triclosan, water flossers) and (3) professional intervention (oral hygiene maintenance, and maintenance of the prosthesis). Conclusions There is minimal evidence related to recall regimens in patients with implant-borne removable and fixed restorations; however, a considerable body of evidence indicates that patients with implant-borne removable and fixed restorations require lifelong professional recall regimens to provide biological and mechanical maintenance, customized for each patient. Current evidence also demonstrates that the use of specific oral topical agents and oral hygiene aids can improve professional and at-home maintenance of implant-borne restorations. There is evidence to demonstrate differences in mechanical and biological maintenance needs due to differences in prosthetic materials and designs. Deficiencies in existing evidence compel the forethought of creating clinical practice guidelines for recall and maintenance of patients with implant-borne dental restorations

    Understanding the interplay between social and spatial behaviour

    Get PDF
    According to personality psychology, personality traits determine many aspects of human behaviour. However, validating this insight in large groups has been challenging so far, due to the scarcity of multi-channel data. Here, we focus on the relationship between mobility and social behaviour by analysing trajectories and mobile phone interactions of ∼1000 individuals from two high-resolution longitudinal datasets. We identify a connection between the way in which individuals explore new resources and exploit known assets in the social and spatial spheres. We show that different individuals balance the exploration-exploitation trade-off in different ways and we explain part of the variability in the data by the big five personality traits. We point out that, in both realms, extraversion correlates with the attitude towards exploration and routine diversity, while neuroticism and openness account for the tendency to evolve routine over long time-scales. We find no evidence for the existence of classes of individuals across the spatio-social domains. Our results bridge the fields of human geography, sociology and personality psychology and can help improve current models of mobility and tie formation

    Quantification of myocardial blood flow with 82Rb positron emission tomography: clinical validation with 15O-water

    Get PDF
    PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine

    Baseline characteristics of patients in the reduction of events with darbepoetin alfa in heart failure trial (RED-HF)

    Get PDF
    <p>Aims: This report describes the baseline characteristics of patients in the Reduction of Events with Darbepoetin alfa in Heart Failure trial (RED-HF) which is testing the hypothesis that anaemia correction with darbepoetin alfa will reduce the composite endpoint of death from any cause or hospital admission for worsening heart failure, and improve other outcomes.</p> <p>Methods and results: Key demographic, clinical, and laboratory findings, along with baseline treatment, are reported and compared with those of patients in other recent clinical trials in heart failure. Compared with other recent trials, RED-HF enrolled more elderly [mean age 70 (SD 11.4) years], female (41%), and black (9%) patients. RED-HF patients more often had diabetes (46%) and renal impairment (72% had an estimated glomerular filtration rate <60 mL/min/1.73 m2). Patients in RED-HF had heart failure of longer duration [5.3 (5.4) years], worse NYHA class (35% II, 63% III, and 2% IV), and more signs of congestion. Mean EF was 30% (6.8%). RED-HF patients were well treated at randomization, and pharmacological therapy at baseline was broadly similar to that of other recent trials, taking account of study-specific inclusion/exclusion criteria. Median (interquartile range) haemoglobin at baseline was 112 (106–117) g/L.</p> <p>Conclusion: The anaemic patients enrolled in RED-HF were older, moderately to markedly symptomatic, and had extensive co-morbidity.</p&gt
    corecore