102 research outputs found

    Ultrafast Ultrasound Imaging

    Get PDF
    Among medical imaging modalities, such as computed tomography (CT) and magnetic resonance imaging (MRI), ultrasound imaging stands out due to its temporal resolution. Owing to the nature of medical ultrasound imaging, it has been used for not only observation of the morphology of living organs but also functional imaging, such as blood flow imaging and evaluation of the cardiac function. Ultrafast ultrasound imaging, which has recently become widely available, significantly increases the opportunities for medical functional imaging. Ultrafast ultrasound imaging typically enables imaging frame-rates of up to ten thousand frames per second (fps). Due to the extremely high temporal resolution, this enables visualization of rapid dynamic responses of biological tissues, which cannot be observed and analyzed by conventional ultrasound imaging. This Special Issue includes various studies of improvements to the performance of ultrafast ultrasoun

    Computer-aided detection of fasciculations and other movements in muscle with ultrasound:Development and clinical application

    Get PDF
    Objective: To develop an automated algorithm for detecting fasciculations and other movements in muscle ultrasound videos. Fasciculation detection in muscle ultrasound is routinely performed online by observing the live videos. However, human observation limits the objective information gained. Automated detection of movement is expected to improved sensitivity and specificity and increase reliability.Methods: We used 42 ultrasound videos from 11 neuromuscular patients for an iterative learning process between human observers and automated computer analysis, to identify muscle ultrasound movements. Two different datasets were selected from this, one to develop the algorithm and one to validate it. The outcome was compared to manual movement identification by clinicians. The algorithm also quantifies specific parameters of different movement types, to enable automated differentiation of events.Results: The algorithm reliably detected fasciculations. With algorithm guidance, observers found more fasciculations compared to visual analysis alone, and prescreening the videos with the algorithm saved clinicians significant time compared to reviewing full video sequences. All videos also contained other movements, especially contraction pseudotremor, which confused human interpretation in some.Conclusions: Automated movement detection is a feasible and attractive method to screen for fasciculations in muscle ultrasound videos.Significance: Our findings affirm the potential clinical usefulness of automated movement analysis in muscle ultrasound

    A Framework for Local Mechanical Characterization of Atherosclerotic Plaques: Combination of Ultrasound Displacement Imaging and Inverse Finite Element Analysis

    Get PDF
    Biomechanical models have the potential to predict plaque rupture. For reliable models, correct material properties of plaque components are a prerequisite. This study presents a new technique, where high resolution ultrasound displacement imaging and inverse finite element (FE) modeling is combined, to estimate material properties of plaque components. Iliac arteries with plaques were excised from 6 atherosclerotic pigs and subjected to an inflation test with pressures ranging from 10 to 120 mmHg. The arteries were imaged with high frequ

    Blinded, multi-centre evaluation of drug-induced changes in contractility using human induced pluripotent stem cell-derived cardiomyocytes

    Get PDF
    Animal models are 78% accurate in determining whether drugs will alter contractility of the human heart. To evaluate the suitability of human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) for predictive safety pharmacology, we quantified changes in contractility, voltage, and/or Ca2+ handling in 2D monolayers or 3D engineered heart tissues (EHTs). Protocols were unified via a drug training set, allowing subsequent blinded multicenter evaluation of drugs with known positive, negative, or neutral inotropic effects. Accuracy ranged from 44% to 85% across the platform-cell configurations, indicating the need to refine test conditions. This was achieved by adopting approaches to reduce signal-to-noise ratio, reduce spontaneous beat rate to ≤ 1 Hz or enable chronic testing, improving accuracy to 85% for monolayers and 93% for EHTs. Contraction amplitude was a good predictor of negative inotropes across all the platform-cell configurations and of positive inotropes in the 3D EHTs. Although contraction- and relaxation-time provided confirmatory readouts forpositive inotropes in 3D EHTs, these parameters typically served as the primary source of predictivity in 2D. The reliance of these “secondary” parameters to inotropy in the 2D systems was not automatically intuitive and may be a quirk of hiPSC-CMs, hence require adaptations in interpreting the data from this model system. Of the platform-cell configurations, responses in EHTs aligned most closely to the free therapeutic plasma concentration. This study adds to the notion that hiPSC-CMs could add value to drug safety evaluation
    • …
    corecore