9 research outputs found

    Dilemmas of Social Workers in Department of Assistance in Material Need

    Get PDF
    KORECKÁ, Veronika. Dilemmas of Social Workers in Department of Assistance in Material Need. Praha, 2019. Diploma Thesis. Charles University, Hussite Theological Faculty. Leader of the Diploma Thesis: Mgr. Tereza Palánová. My thesis deals with dilemmas which are met by employees working at the Departement of Material Emergency. As for dilemmas it focuses on reasons of their genesis, the employees approach towards them and their solutions. In the theoretical part the system of social security in the Czech Republic, which includes the Unemployement Office with the Departement of Material Emergency, is briefly introduced. Readers' attention is drawn to particular benefits of material emergency. Next, the thesis defines the concepts of a social worker, social work and dilemmas. All of them are related to the topic of the thesis. The empirical part presents the research investigation which was aimed at social workers at the Departement of Material Emergency and their relation towards dilemmas. The aim was to find out which dilemma situations are present in their practice and how they deal with them. The qualitative method of half structured interview was used to fulfil the objectives. The investigation revealed particular dilemma situations of social workers. Next the investigation showed how social...KORECKÁ, Veronika. Dilemata sociálních pracovníků na oddělení pomoci v hmotné nouzi. Praha, 2019. Diplomová práce. Univerzita Karlova, Husitská teologická fakulta. Vedoucí práce Mgr. Tereza Palánová. Diplomová práce se věnuje dilematům, se kterými se setkávají sociální pracovníci na oddělení pomoci v hmotné nouzi. Ve věci dilemat se soustředí na důvody jejich vzniku, přístup sociálních pracovníků k nim a jejich řešení. V teoretické části je stručně představen systém sociálního zabezpečení ČR, v rámci kterého funguje Úřad práce ČR s oddělením pomoci v hmotné nouzi. Pozornost je věnována jednotlivým dávkám pomoci v hmotné nouzi. Dále se práce zaměřuje na vymezení pojmů sociální pracovník, sociální práce a dilemata. Všechny pojmy jsou vztaženy k tématu práce. Empirická část je věnována výzkumnému šetření, které bylo zaměřené na sociální pracovníky oddělení pomoci v hmotné nouzi ve vztahu k dilematům. Cílem bylo zjistit, jaké dilematické situace se vyskytují v jejich praxi a jak k nim přistupují. K naplnění cílů práce byla použita kvalitativní metoda polostrukturovaného rozhovoru. Výzkumným šetřením byly zjištěny konkrétní dilematické situace sociálních pracovníků. Dále z výzkumného šetření vyplynulo, jak sociální pracovníci dilemata vnímají a jaké užívají postupy pro jejich vyřešení.HTF - Katedra psychosociálních věd a etikyHussite Theological FacultyHusitská teologická fakult

    Dilemmas of Social Workers in Department of Assistance in Material Need

    No full text
    KORECKÁ, Veronika. Dilemmas of Social Workers in Department of Assistance in Material Need. Praha, 2019. Diploma Thesis. Charles University, Hussite Theological Faculty. Leader of the Diploma Thesis: Mgr. Tereza Palánová. My thesis deals with dilemmas which are met by employees working at the Departement of Material Emergency. As for dilemmas it focuses on reasons of their genesis, the employees approach towards them and their solutions. In the theoretical part the system of social security in the Czech Republic, which includes the Unemployement Office with the Departement of Material Emergency, is briefly introduced. Readers' attention is drawn to particular benefits of material emergency. Next, the thesis defines the concepts of a social worker, social work and dilemmas. All of them are related to the topic of the thesis. The empirical part presents the research investigation which was aimed at social workers at the Departement of Material Emergency and their relation towards dilemmas. The aim was to find out which dilemma situations are present in their practice and how they deal with them. The qualitative method of half structured interview was used to fulfil the objectives. The investigation revealed particular dilemma situations of social workers. Next the investigation showed how social..

    New approach in electrochemical immunomagnetic biosensors for protein detection

    No full text
    The simple, sensitive, and selective method for electrochemical detection of ovalbumin is presented. This method is a combination of the selective immunocomplex formation on the surface of magnetic carriers for easy manipulation and preconcentration with a very sensitive electrochemical detection. The evaluation of antigen content is based on electrochemical detection of quantum dots as labels of secondary antibodies, which allows detecting of low amounts of target antigen

    Voltametrická detekce QDs značených protilátek na bismutem modifikovaných tištěných elektrodách

    No full text
    Specific antibodies can be labelled by quantum dots (QDs) as a suitable alternative to enzymes in immunoassays. Advantages of QDs are known in the field of fluorescent immunoassays. Nevertheless, here we present the possibility of simple and highly sensitive electrochemical detection of QDs by stripping voltammetry on disposable screen printed electrodes. Moreover, modification of working electrode with in situ bismuth film could be successfully used instead of sensors with mercury film. Alpha-fetoprotein (AFP) as a protein from the group of ovarian cancer tumor markers and corresponding IgG antibodies were used as antigen-antibody system.Specifické protilátky mohou být značeny kvantovými tečkami, které slouží jako vhodná náhrada enzymů v imunoanalýzách. Výhodné použití QDs je především na poli fluorescenčních imunoanalýz. Nicméně, v tomto příspěvku prezentujeme možnost jednoduché a senzitivní elektrochemické detekce s využitím QDs a rozpouštěcí voltametrie na tištěných elektrodách. V současné době je snaha využívat elektrod s bismutovým filmem místo elektrod s rtuťovým filmem. Pro značení kvantovými tečkami bylo využito systému pro detekci antigenu alfa-fetoproteinu

    Alkalickou fosfatázou funkcionalizované mezoporézní silika nanočástice pro značení protilátek v imunosenzorech

    No full text
    Currently, the new ways how to improve the sensitivity of commonly used ELISA methods for detection of biomarkers are being found. The possibility how to achieve lower detection limits is the use of secondary antibodies labeled with nanoparticles modified by enzymes instead of antibodies labelled only by enzymes. Here we present ALP-modified silica mesoporous nanoparticles utilized for labelling of anti-ApoE IgG antibodies for quantification of apolipoprotein E (ApoE) by sandwich-type magneto-imunosorbent enzyme assay combined with square wave voltammetry. In this arrangement we achieved linear calibration curve in the concentration range of 75 – 500 ng/ml.V současné době jsou hledány nové způsoby, jak zvýšit citlivost běžně používaných ELISA metod pro detekci biomarkerů. Jednou z možností, jak dosáhnout nižších limitů detekce, je použití sekundárních protilátek značených nanočásticemi, které jsou modifikovány enzymy. ALP-modifikované silika nanočástice jsou využívány pro značení anti-ApoE IgG protilátek, jež jsou následně použity pro kvantifikaci antigenu apolipoproteinu E (ApoE) s následnou elektrochemickou detekcí (square wave voltametrie). Tímto uspořádáním bylo dosaženo lineární kalibrační řady v koncentračním rozmezí 75 – 500 ng/ml

    HRP-modified nanoparticles and their application in immunosensors

    No full text
    Cílem práce bylo funkcionalizovat nanočástice s karboxylovou funkční skupinou (NPs-COOH) enzymem křenovou peroxidázou (HRP), kterými byly následně značeny sekundární protilátky pro imunosenzory pracující na principu ELISA metody. Připravený konjugát (anti-ApoE IgGNPs-HRP) byl poté použit pro elektrochemickou detekci antigenu apoliproteinu E (ApoE).This work aimed in biofunctionalization of carboxylate nanoparticles (NPs-COOH) with enzyme horseradish peroxidase (HRP) for subsequent nanolabelling of specific antibody in ELISA – based immunosensors. Finally prepared conjugate (anti-ApoE IgGNPs-HRP) was applied for electrochemical detection of antigen apolipoprotein E (ApoE)

    Elektrochemický magneto-imunosenzor pro detekci proteinu HE4 založený na kvantových tečkách a tištěných uhlíkových elektrodách s kovovým filmem

    No full text
    A novel enzyme-free electrochemical immunosensor was developed for highly sensitive detection and quantification of human epididymis protein 4 (HE4) in human serum. For the first time, core/shell CdSe/ZnS quantum dots were conjugated with anti-HE4 IgG antibodies for subsequent sandwich-type immunosensing with super paramagnetic microparticles functionalized with anti-HE4 IgG antibodies, which allow rapid and efficient HE4 capture from the sample. Electrochemical detection of anti-HE4 IgG - HE4 - anti-HE4 IgG(CdSe/ZnS) immunocomplex was performed by recording the current response of Cd(II) ions, released from dissolved quantum dots at screen-printed carbon electrode (SPCE), modified with mercury or bismuth film. The linear range of the detection was from 20 pM to 40 nM with limit of detection of 12 pM using three times the standard deviation of blank criterion at mercury-film SPCE and from 100 pM to 2 nM with limit of detection of 89 pM at bismuth-film SPCE. Proposed electrochemical immunosensor meets the requirements for fast and sensitive quantification of HE4 biomarker in early stage of ovarian cancer and due to the proper sensitivity and specificity presents a promising alternative to enzyme-based probes used routinely in clinical diagnostics.Nový, bezenzymový elektrochemický imunosenzor byl vyvinut pro vysoce citlivou detekci a kvantifikaci proteinu HE4 v lidském séru. Nejprve byly využity core/shell kvantové tečky CdSe/ZnS, které byly konjugovány s anti-HE4 protilátkami pro následné sestavení sendvičového imunosenzoru využívajícího superparamagnetické mikročástice funkcionalizované anti-HE4 protilátkami, které umožňují účinné zachycení HE4 proteinu ze vzorku. Elektrochemická detekce anti-HE4 IgG-HE4-anti-HE4 IgG(CdSe/ZnS) imunokomplexu byla přes zaznamenání proudové odezvy Cd(II) iontů uvolněných z kvantových teček po jejich rozpuštění v kyselém prostředí. Byly využity tištěné uhlíkové senzory (SPCE) modifikované rtuťovým nebo bismutovým filmem. Lineární rozsah byl 20 pM - 40 nM s limitem detekce 12 pM na rtuťové elektrodě a 100 pM - 2 nM s limitem detekce 89 pM na bismutové elektrodě. Elektrochemický imunosenzor splňuje požadavky na rychlou a citlivou kvantifikaci HE4 proteinu a může být využit pro včasnou diagnostiku ovariálního karcinomu. Zároveň může být vhodnou alternativou k enzymovým imunoanalýzám nyní rutinně využívaným v klinické laboratorní diagnostice

    Modelový systém s kvantovými tečkami pro simultánní elektrochemickou imunoanalýzu klinických biomarkerů

    No full text
    Rapid and sensitive detection of significant clinical biomarker are currently of great importance. The widely used analytical methods for their detection are based on enzyme linked immunosorbent assays (ELISA). However, they have limitations in simultaneous detection of panel markers within one analysis. However quantum dots (QDs) represented recently new way in antibodies labeling and in connection to electrochemical SWASV detection are capable tags for immunoanalytical assays. Mixture of quantum dots made of three different materials for potential simultaneous detection of protein biomarkers and detected electrochemically is presented. The results with mercury film and "mercury free" bismuth film electrodes are compared.Rychlá a citlivá detekce klinicky významných biomarkerů je velmi žádoucí. Široce užívané analytické metody využívané k jejich dekci jsou založené na ELISA metodě. Tyto metody mají ale svá omezení pro simultánní analýzu panelu biomarkerů v rámci jedné analýzy. Kvantové tečky v současné době představují nový typ značení protilátek ve spojení s elekctrochemickou SWASV detekcí a jsou tak vhodné pro imunoanalytické analýzy. V tomto příspěvku je prezentována elektrochemická detekce směsi kvantových teček složených ze tří různých materiálů pro potenciální simultánní dtekci proteinových biomarkerů
    corecore