9 research outputs found

    ベルト・モリゾと日本美術(1) : 扇・団扇のジャポニスムから1890年ビングの「日本版画展」まで

    Get PDF
    textabstractA human genomic fragment comprising the cellular retinoic acid binding protein (CRABP) gene was isolated. By using a panel of somatic cell hybrids, this gene could be assigned to human chromosome 15. Subsequently, a possible involvement of the CRABP gene in translocation (15;17) (q22;q11) positive acute promyelocytic leukemia (APL) was investigated. Although transposition of the CRABP gene could be demonstrated, we did not observe any gross CRABP rearrangement in a series of primary APL patients, nor in the acute myeloblastic leukemia cell line HL-60. Thus, the observed lack of CRABP expression in these leukemic cells may not be caused by disruption of its gene. CRABP maps to the region 15q22-qter

    [Prevalence of caries and dental erosion among school children in The Hague from 1996-2005]

    Get PDF
    Contains fulltext : 51679.pdf (publisher's version ) (Open Access)In 2005 a dental survey of the prevalence of caries among 6- and 12-year-old schoolchildren in The Hague was carried out. In the case of the 12-year-olds, the prevalence of dental erosion was also studied. The sample consisted of 814 students in twelve primary schools in The Hague. The results reveal that since the previous study, in 2002, the trend in the direction of an increasing percentage of children with deciduous caries-free teeth and permanent caries-free teeth had continued. In the case of the children who were not caries-free, it was noticeable that, in general, the number of new dental caries (dmfs- and DMFS-score) had not changed in the period 1996-2005, while the number of restorations among the 6- and 12-year olds had decreased. The mean restorative index in the deciduous dentition of 6-year-olds decreased from approximately 40% in 1996 to approximately 20% in 2005; with respect to permanant dentition among 12-year-olds, the percentage decreased from more than 90% to 60%. The percentage of 12-year-olds with dental erosion in 2005 remained unchanged as compared with 2002: 24%. The research revealed that there was no increase in dental caries or dental erosion among the 6- and 12-year-old school children in The Hague

    Biomechanical evaluation of additively manufactured patient-specific mandibular cage implants designed with a semi-automated workflow:A cadaveric and retrospective case study

    Get PDF
    Objective: Mandibular reconstruction using patient-specific cage implants is a promising alternative to the vascularized free flap reconstruction for nonirradiated patients with adequate soft tissues, or for patients whose clinical condition is not conducive to microsurgical reconstruction. This study aimed to assess the biomechanical performance of 3D printed patient-specific cage implants designed with a semi-automated workflow in a combined cadaveric and retrospective case series study. Methods: We designed cage implants for two human cadaveric mandibles using our previously developed design workflow. The biomechanical performance of the implants was assessed with the finite element analysis (FEA) and quasi-static biomechanical testing. Digital image correlation (DIC) was used to measure the full-field strains and validate the FE models by comparing the distribution of maximum principal strains within the bone. The retrospective study of a case series involved three patients, each of whom was treated with a cage implant of similar design. The biomechanical performance of these implants was evaluated using the experimentally validated FEA under the scenarios of both mandibular union and nonunion. Results: No implant or screw failure was observed prior to contralateral bone fracture during the quasi-static testing of both cadaveric mandibles. The FEA and DIC strain contour plots indicated a strong linear correlation (r = 0.92) and a low standard error (SE=29.32με), with computational models yielding higher strain values by a factor of 2.7. The overall stresses acting on the case series’ implants stayed well below the yield strength of additively manufactured (AM) commercially pure titanium, when simulated under highly strenuous chewing conditions. Simulating a full union between the graft and remnant mandible yielded a substantial reduction (72.7±1.5%) in local peak stresses within the implants as compared to a non-bonded graft. Conclusions: This study shows the suitability of the developed semi-automated workflow in designing patient-specific cage implants with satisfactory mechanical functioning under demanding chewing conditions. The proposed workflow can aid clinical engineers in creating reconstruction systems and streamlining pre-surgical planning. Nevertheless, more research is still needed to evaluate the osteogenic potential of bone graft insertions.</p

    Biomechanical evaluation of additively manufactured patient-specific mandibular cage implants designed with a semi-automated workflow: A cadaveric and retrospective case study

    No full text
    Objective: Mandibular reconstruction using patient-specific cage implants is a promising alternative to the vascularized free flap reconstruction for nonirradiated patients with adequate soft tissues, or for patients whose clinical condition is not conducive to microsurgical reconstruction. This study aimed to assess the biomechanical performance of 3D printed patient-specific cage implants designed with a semi-automated workflow in a combined cadaveric and retrospective case series study. Methods: We designed cage implants for two human cadaveric mandibles using our previously developed design workflow. The biomechanical performance of the implants was assessed with the finite element analysis (FEA) and quasi-static biomechanical testing. Digital image correlation (DIC) was used to measure the full-field strains and validate the FE models by comparing the distribution of maximum principal strains within the bone. The retrospective study of a case series involved three patients, each of whom was treated with a cage implant of similar design. The biomechanical performance of these implants was evaluated using the experimentally validated FEA under the scenarios of both mandibular union and nonunion. Results: No implant or screw failure was observed prior to contralateral bone fracture during the quasi-static testing of both cadaveric mandibles. The FEA and DIC strain contour plots indicated a strong linear correlation (r = 0.92) and a low standard error (SE=29.32με), with computational models yielding higher strain values by a factor of 2.7. The overall stresses acting on the case series’ implants stayed well below the yield strength of additively manufactured (AM) commercially pure titanium, when simulated under highly strenuous chewing conditions. Simulating a full union between the graft and remnant mandible yielded a substantial reduction (72.7±1.5%) in local peak stresses within the implants as compared to a non-bonded graft. Conclusions: This study shows the suitability of the developed semi-automated workflow in designing patient-specific cage implants with satisfactory mechanical functioning under demanding chewing conditions. The proposed workflow can aid clinical engineers in creating reconstruction systems and streamlining pre-surgical planning. Nevertheless, more research is still needed to evaluate the osteogenic potential of bone graft insertions.Biomaterials & Tissue Biomechanic

    Semi-automated digital workflow to design and evaluate patient-specific mandibular reconstruction implants

    Get PDF
    The reconstruction of large mandibular defects with optimal aesthetic and functional outcomes remains a major challenge for maxillofacial surgeons. The aim of this study was to design patient-specific mandibular reconstruction implants through a semi-automated digital workflow and to assess the effects of topology optimization on the biomechanical performance of the designed implants. By using the proposed workflow, a fully porous implant (LA-implant) and a topology-optimized implant (TO-implant) both made of Ti–6Al–4V ELI were designed and additively manufactured using selective laser melting. The mechanical performance of the implants was predicted by performing finite element analysis (FEA) and was experimentally assessed by conducting quasi-static and cyclic biomechanical tests. Digital image correlation (DIC) was used to validate the FE model by comparing the principal strains predicted by the FEM model with the measured distribution of the same type of strain. The numerical predictions were in good agreement with the DIC measurements and the predicted locations of specimen failure matched the actual ones. No statistically significant differences (p 1000 N) than the average maximum biting force of healthy individuals. Given its relatively lower weight (16.5%), higher porosity (17.4%), and much shorter design time (633.3%), the LA-implant is preferred for clinical application. This study clearly demonstrates the capability of the proposed workflow to develop patient-specific implants with high precision and superior mechanical performance, which will greatly facilitate cost- and time-effective pre-surgical planning and is expected to improve the surgical outcome
    corecore