591 research outputs found

    Effect of catalyst layer defects on local membrane degradation in polymer electrolyte fuel cells

    Get PDF
    © 2016 Elsevier B.V. All rights reserved. Aiming at durability issues of fuel cells, this research is dedicated to a novel experimental approach in the analysis of local membrane degradation phenomena in polymer electrolyte fuel cells, shedding light on the potential effects of manufacturing imperfections on this process. With a comprehensive review on historical failure analysis data from field operated fuel cells, local sources of iron oxide contaminants, catalyst layer cracks, and catalyst layer delamination are considered as potential candidates for initiating or accelerating the local membrane degradation phenomena. Customized membrane electrode assemblies with artificial defects are designed, fabricated, and subjected to membrane accelerated stress tests followed by extensive post-mortem analysis. The results reveal a significant accelerating effect of iron oxide contamination on the global chemical degradation of the membrane, but dismiss local traces of iron oxide as a potential stressor for local membrane degradation. Anode and cathode catalyst layer cracks are observed to have negligible impact on the membrane degradation phenomena. Notably however, distinct evidence is found that anode catalyst layer delamination can accelerate local membrane thinning, while cathode delamination has no apparent effect. Moreover, a substantial mitigating effect for platinum residuals on the site of delamination is observed

    Polya's inequalities, global uniform integrability and the size of plurisubharmonic lemniscates

    Full text link
    First we prove a new inequality comparing uniformly the relative volume of a Borel subset with respect to any given complex euclidean ball \B \sub \C^n with its relative logarithmic capacity in \C^n with respect to the same ball \B. An analoguous comparison inequality for Borel subsets of euclidean balls of any generic real subspace of \C^n is also proved. Then we give several interesting applications of these inequalities. First we obtain sharp uniform estimates on the relative size of \psh lemniscates associated to the Lelong class of \psh functions of logarithmic singularities at infinity on \C^n as well as the Cegrell class of \psh functions of bounded Monge-Amp\`ere mass on a hyperconvex domain \W \Sub \C^n. Then we also deduce new results on the global behaviour of both the Lelong class and the Cegrell class of \psh functions.Comment: 25 page

    Observation of individual molecules trapped on a nanostructured insulator

    Full text link
    For the first time, ordered polar molecules confined in monolayer-deep rectangular pits produced on an alkali halide surface by electron irradiation have been resolved at room temperature by non-contact atomic force microscopy. Molecules self-assemble in a specific fashion inside pits of width smaller than 15 nm. By contrast no ordered aggregates of molecules are observed on flat terraces. Conclusions regarding nucleation and ordering mechanisms are drawn. Trapping in pits as small as 2 nm opens a route to address single molecules

    Impact of an interatrial shunt device on survival and heart failure hospitalization in patients with preserved ejection fraction

    Get PDF
    Aims: Impaired left ventricular diastolic function leading to elevated left atrial pressures, particularly during exertion, is a key driver of symptoms and outcomes in heart failure with preserved ejection fraction (HFpEF). Insertion of an interatrial shunt device (IASD) to reduce left atrial pressure in HFpEF has been shown to be associated with short‐term haemodynamic and symptomatic benefit. We aimed to investigate the potential effects of IASD placement on HFpEF survival and heart failure hospitalization (HFH). Methods and results: Heart failure with preserved ejection fraction patients participating in the Reduce Elevated Left Atrial Pressure in Patients with Heart Failure study (Corvia Medical) of an IASD were followed for a median duration of 739 days. The theoretical impact of IASD implantation on HFpEF mortality was investigated by comparing the observed survival of the study cohort with the survival predicted from baseline data using the Meta‐analysis Global Group in Chronic Heart Failure heart failure risk survival score. Baseline and post‐IASD implant parameters associated with HFH were also investigated. Based upon the individual baseline demographic and cardiovascular profile of the study cohort, the Meta‐analysis Global Group in Chronic Heart Failure score‐predicted mortality was 10.2/100 pt years. The observed mortality rate of the IASD‐treated cohort was 3.4/100 pt years, representing a 33% lower rate (P = 0.02). By Kaplan–Meier analysis, the observed survival in IASD patients was greater than predicted (P = 0.014). Baseline parameters were not predictive of future HFH events; however, poorer exercise tolerance and a higher workload‐corrected exercise pulmonary capillary wedge pressure at the 6 months post‐IASD study were associated with HFH. Conclusions: The current study suggests IASD implantation may be associated with a reduction in mortality in HFpEF. Large‐scale ongoing randomized studies are required to confirm the potential benefit of this therapy

    The NLO QCD Corrections to BcB_c Meson Production in Z0Z^0 Decays

    Full text link
    The decay width of Z0Z^0 to BcB_c meson is evaluated at the next-to-leading order(NLO) accuracy in strong interaction. Numerical calculation shows that the NLO correction to this process is remarkable. The quantum chromodynamics(QCD)renormalization scale dependence of the results is obviously depressed, and hence the uncertainties lying in the leading order calculation are reduced.Comment: 14 pages, 7 figures; references added; expressions and typos ammende

    Fuel cell durability enhancement with cerium oxide under combined chemical and mechanical membrane degradation

    Get PDF
    © The Author(s) 2015. Published by ECS. A CeO2 supported membrane electrode assembly (MEA) was fabricated by hot-pressing CeO2-coated electrodes and a PFSA ionomer membrane. Upon application of a combined chemical and mechanical accelerated stress test (AST), the CeO2 supported MEAshowed six times longer lifetime and 40 times lower fluoride emission rate than a baselineMEA without cerium. Themembrane in the CeO2 supported MEA effectively retained its original thickness and ductility despite the highly aggressive AST conditions. Most of the cerium applied on the anode migrated into the membrane and provided excellent mitigation of joint chemical and mechanical membrane degradation

    One-year outcomes after transcatheter insertion of an interatrial shunt device for the management of heart failure with preserved ejection fraction

    Get PDF
    Background—Heart failure with preserved ejection fraction has a complex pathophysiology and remains a therapeutic challenge. Elevated left atrial pressure, particularly during exercise, is a key contributor to morbidity and mortality. Preliminary analyses have demonstrated that a novel interatrial septal shunt device that allows shunting to reduce the left atrial pressure provides clinical and hemodynamic benefit at 6 months. Given the chronicity of heart failure with preserved ejection fraction, evidence of longer-term benefit is required. Methods and Results—Patients (n=64) with left ventricular ejection fraction ≄40%, New York Heart Association class II–IV, elevated pulmonary capillary wedge pressure (≄15 mm Hg at rest or ≄25 mm Hg during supine bicycle exercise) participated in the open-label study of the interatrial septal shunt device. One year after interatrial septal shunt device implantation, there were sustained improvements in New York Heart Association class (P<0.001), quality of life (Minnesota Living with Heart Failure score, P<0.001), and 6-minute walk distance (P<0.01). Echocardiography showed a small, stable reduction in left ventricular end-diastolic volume index (P<0.001), with a concomitant small stable increase in the right ventricular end-diastolic volume index (P<0.001). Invasive hemodynamic studies performed in a subset of patients demonstrated a sustained reduction in the workload corrected exercise pulmonary capillary wedge pressure (P<0.01). Survival at 1 year was 95%, and there was no evidence of device-related complications. Conclusions—These results provide evidence of safety and sustained clinical benefit in heart failure with preserved ejection fraction patients 1 year after interatrial septal shunt device implantation. Randomized, blinded studies are underway to confirm these observations

    The BcB_c Decays to PP-wave Charmonium by Improved Bethe-Salpeter Approach

    Full text link
    We re-calculate the exclusive semileptonic and nonleptonic decays of BcB_c meson to a PP-wave charmonium in terms of the improved Bethe-Salpeter (B-S) approach, which is developed recently. Here the widths for the exclusive semileptonic and nonleptonic decays, the form factors, and the charged lepton spectrums for the semileptonic decays are precisely calculated. To test the concerned approach by comparing with experimental measurements when the experimental data are available, and to have comparisons with the other approaches the results obtained by the approach and those by some approaches else as well as the original B-S approach, which appeared in literature, are comparatively presented and discussed.Comment: 33 pages, 5 figures, 3 table
    • 

    corecore