22 research outputs found

    A giant plexiform schwannoma of the brachial plexus: case report

    Get PDF
    We report the case of a patient who noticed muscle weakness in his left arm 5 years earlier. On examination, a biloculate mass was observed in the left supraclavicular area, and Tinel's sign caused paresthesia in his left arm. Magnetic resonance imaging showed a continuous, multinodular, plexiform tumor from the left C5 to C7 nerve root along the course of the brachial plexus to the left brachia. Tumor excision was attempted. The median and musculocutaneous nerves were extremely enlarged by the tumor, which was approximately 40 cm in length, and showed no response to electric stimulation. We resected a part of the musculocutaneous nerve for biopsy and performed latissimus dorsi muscle transposition in order to repair elbow flexion. Morphologically, the tumor consisted of typical Antoni A areas, and immunohistochemistry revealed a Schwann cell origin of the tumor cells moreover, there was no sign of axon differentiation in the tumor. Therefore, the final diagnosis of plexiform Schwannoma was confirmed

    Case Report Fabella Syndrome as an Uncommon Cause of Posterolateral Knee Pain after Total Knee Arthroplasty: A Case Report and Review of the Literature

    Get PDF
    The fabella is a sesamoid bone that is located in the lateral head of the gastrocnemius muscle and has been identified on magnetic resonance imaging in 31% of Japanese people. In the present case, a 65-year-old woman experienced posterolateral knee pain, accompanied by a clicking "sound" during active knee flexion, after undergoing total knee arthroplasty for knee osteoarthritis. Eight months of conservative therapy failed to produce an improvement, with progressive osteoarthritic change of the fabella identified on plain radiography. Based on this evidence, a diagnosis of fabella syndrome was made and the patient underwent a fabellectomy. Fabellectomy provided immediate resolution of posterolateral knee pain and the clicking sound with knee flexion, with the patient remaining symptom-free 18 months after fabellectomy and with no limitations in knee function. Fabellectomy eliminated symptoms in all of five case reports that have been previously published and is regarded as an effective first choice for treating fabella syndrome after total knee arthroplasty

    An isolated rupture of the flexor digitorum tendon of the index finger following volar locking plate fixation of a distal radius fracture: A case report

    No full text
    Volar locking plates (VLP) have been widely used recently to treat distal radius fractures and are considered the gold standard. One of the most common complications of distal radius fracture surgery is flexor pollicis longus rupture, which may also occur in other tendons. Here, we report a case of isolated rupture of the flexor digitorum profundus to the index finger after VLP fixation of a distal radial fracture. Only a few cases of this have been reported in the literature. In previously reported cases, the cause of tendon rupture was repetitive mechanical stress due to implant protrusion. In our case, the plate was placed too distally; however, soft tissue completely covered the distal part of the plate. There was obvious synovitis within the carpal tunnel; therefore, pressure within the carpal tunnel may have increased. The cause of rupture in our case was thought to be a combination of direct mechanical stress and poor circulation due to inadequate VLP fixation

    Correlations between 3D preoperative planning and postoperative reduction in the osteosynthesis of distal humeral fractures

    No full text
    Abstract Background Three-dimensional preoperative planning has been applied to the osteosynthesis of distal humerus fractures. The present study investigated the correlations between 3D preoperative planning and postoperative reduction for the osteosynthesis of distal humerus fractures using 3D parameters. Methods Twenty-three elbows of 23 distal humerus fracture patients who underwent osteosynthesis with three-dimensional preoperative planning were evaluated. 3D images of the distal humerus were created after taking preoperative CT scans of the injured elbow. Fracture reduction, implant selection, and placement simulations were performed based on 3D images. Postoperative CT images were taken 1 month after surgery. Correlations were evaluated with preoperative plans and postoperative 3D images. The longitudinal axis and coordinates of the humerus were defined on the 3D images. The coronal angle (CA) was defined as the angle formed by the long axis and the line connecting the medial and lateral margins of the trochlea of the humerus on a coronal plane image. The sagittal angle (SA) was defined as the angle formed by the long axis and the line connecting the top of the lateral epicondyle and the center of the humeral capitellum on a sagittal plane image. The axial angle (AA) was defined as the angle between the sagittal plane and the line connecting the medial and lateral margins behind the trochlea of the humerus. The intraclass correlation coefficients (ICC) of each measurement value were assessed between preoperative planning and postoperative images. Results Preoperative planning and postoperative measurement values were CA: 85.6 ± 5.9°/85.8 ± 5.9°, SA: 140.9 ± 8.5°/139.4 ± 7.9°, and AA: 84.0 ± 3.1°/82.6 ± 4.9°, respectively. ICCs were CA: 0.75 (P < 0.01), SA: 0.78 (P < 0.01), and AA: 0.34 (P < 0.05), respectively. Conclusions The 3D preoperative planning of distal humeral fractures achieved the good correlations of coronal and sagittal angles, but the relatively poor correlation of the axial angle. This may be attributed to an inability to assess the rotation angle during surgery. We propose the measurement indices shown in the present study as a three-dimensional evaluation index for distal humerus fractures. Trial registration Registered as NCT04349319 at ClinicalTrials.gov

    Advances in Bone Joint Imaging-Metal Artifact Reduction

    No full text
    Numerous types of metal implants have been introduced in orthopedic surgery and are used in everyday practice. To precisely evaluate the postoperative condition of arthroplasty or trauma surgery, periprosthetic infection, and the loosening of implants, it is important to reduce artifacts induced by metal implants. In this review, we focused on technical advances in metal artifact reduction using digital tomosynthesis, computed tomography, and magnetic resonance imaging. We discussed new developments in diagnostic imaging methods and the continuous introduction of novel technologies to reduce metal artifacts; however, these innovations have not yet completely removed metal artifacts. Different algorithms need to be selected depending on the size, shape, material and implanted body parts of an implant. Future advances in metal artifact reduction algorithms and techniques and the development of new sequences may enable further reductions in metal artifacts even on original images taken previously. Moreover, the combination of different imaging modalities may contribute to further reductions in metal artifacts. Clinicians must constantly update their knowledge and work closely with radiologists to select the best diagnostic imaging method for each metal implant

    Injury-Induced HSP27 Expression in Peripheral Nervous Tissue Is Not Associated with Any Alteration in Axonal Outgrowth after Immediate or Delayed Nerve Repair

    No full text
    We investigated injury-induced heat shock protein 27 (HSP27) expression and its association to axonal outgrowth after injury and different nerve repair models in healthy Wistar and diabetic Goto-Kakizaki rats. By immunohistochemistry, expression of HSP27 in sciatic nerves and DRG and axonal outgrowth (neurofilaments) in sciatic nerves were analyzed after no, immediate, and delayed (7-day delay) nerve repairs (7- or 14-day follow-up). An increased HSP27 expression in nerves and in DRG at the uninjured side was associated with diabetes. HSP27 expression in nerves and in DRG increased substantially after the nerve injuries, being higher at the site where axons and Schwann cells interacted. Regression analysis indicated a positive influence of immediate nerve repair compared to an unrepaired injury, but a shortly delayed nerve repair had no impact on axonal outgrowth. Diabetes was associated with a decreased axonal outgrowth. The increased expression of HSP27 in sciatic nerve and DRG did not influence axonal outgrowth. Injured sciatic nerves should appropriately be repaired in healthy and diabetic rats, but a short delay does not influence axonal outgrowth. HSP27 expression in sciatic nerve or DRG, despite an increase after nerve injury with or without a repair, is not associated with any alteration in axonal outgrowth.Funding Agencies|Lund University; Region Skane; Skane University Hospital; Swedish Diabetes Foundation</p

    Trapezium Fracture Associated with Thumb Carpometacarpal Joint Dislocation: A Report of Three Cases and Literature Review

    No full text
    Isolated trapezium fracture in combination with thumb carpometacarpal (CMC) joint dislocation is extremely rare, and no treatment consensus exists. Herein, we report 3 successfully treated cases of isolated trapezium fracture with thumb CMC joint dislocation. While good short-term results have been reported in the literature, the possibility of substantial ligament injuries that can lead to future instability of the thumb CMC joint must be noted. In order to obtain an excellent long-term clinical result, we propose the consideration of the anatomical repair of the CMC joint in terms of both bony and ligamentous structures in cases where instability remains after fracture fixation

    Potential Relationships between the Median Nerve Cross-Sectional Area and Physical Characteristics in Unilateral Symptomatic Carpal Tunnel Syndrome Patients

    No full text
    Background: The present study investigated the relationships between the median nerve cross-sectional area (CSA) and physical characteristics in patients with unilateral symptomatic carpal tunnel syndrome (CTS). Methods: Height, weight, body mass index (BMI), disease duration, results of electrodiagnostic testing (EDX), and median nerve CSA at the level of the wrist crease were recorded in 81 patients with CTS who presented with symptoms on only one side. Correlation coefficients between median nerve CSA and physical characteristics, disease duration, and results of EDX were analyzed. Results: Median nerve CSA at the wrist crease (mm2) was significantly larger on the symptomatic side (14.1 ± 3.8) than on the asymptomatic side (11.5 ± 2.9). Median nerve CSA correlated with body weight (correlation coefficient = 0.39) and BMI (correlation coefficient = 0.44) on the asymptomatic side, but not on the symptomatic side. These correlations were slightly stronger in females (correlation coefficient = 0.46) than in males (correlation coefficient = 0.40). No correlations between median nerve CSA and disease duration and the results of EDX were observed in both sides. Conclusions: In patients with unilateral symptomatic CTS, median nerve CSA correlated with BMI only on the asymptomatic side. The present results suggest that the relationship between median nerve CSA and BMI in CTS is significant until symptom onset but may be masked by edema and pseudoneuroma after its onset. A higher BMI is associated with a larger CSA of the median nerve, which may be a risk factor for the development of CTS

    Individual Evaluation of the Common Extensor Tendon and Lateral Collateral Ligament Improves the Severity Diagnostic Accuracy of Magnetic Resonance Imaging for Lateral Epicondylitis

    No full text
    The effectiveness of magnetic resonance imaging for diagnosing lateral epicondylitis severity is controversial. We aimed to verify whether individual evaluations of the common extensor tendon and lateral collateral ligament would improve the severity diagnostic accuracy of magnetic resonance imaging for lateral epicondylitis. We obtained coronal images of the lateral elbow in three groups: healthy, clinically mild, and clinically severe. We used our scoring system for evaluation using combined and individual methods. We developed the receiver operating characteristic curve for diagnosis using the scores of the healthy and mild groups and that for severity diagnosis using the scores of the mild and severe groups. The scores, in decreasing value, were those of the severe, mild, and healthy groups, with a significant difference in both methods. The curve for diagnosis showed an area under the curve of 0.85 for the combined evaluation and 0.89 for the individual evaluation, without a significant difference between the methods (p = 0.23). The curve for severity diagnosis showed an area under the curve of 0.69 for combined and 0.81 for individual evaluation, with a significant difference between the methods (p = 0.046). Individual evaluation of the common extensor tendon and lateral collateral ligament improved the severity diagnostic accuracy of lateral epicondylitis
    corecore