2,465 research outputs found
Collapse of a Bose gas: kinetic approach
We have analytically explored temperature dependence of critical number of
particles for the collapse of a harmonically trapped attractively interacting
Bose gas below the condensation point by introducing a kinetic approach within
the Hartree-Fock approximation. The temperature dependence obtained by this
easy approach is consisted with that obtained from the scaling theory.Comment: Brief Report, 4 pages, 1 figure, Accepted in Pramana-Journal of
Physic
The IHI Rochester Report 2022 on Healthcare Informatics Research: Resuming After the CoViD-19
In 2020, the CoViD-19 pandemic spread worldwide in an unexpected way and suddenly modified many life issues, including social habits, social relationships, teaching modalities, and more. Such changes were also observable in many different healthcare and medical contexts. Moreover, the CoViD-19 pandemic acted as a stress test for many research endeavors, and revealed some limitations, especially in contexts where research results had an immediate impact on the social and healthcare habits of millions of people. As a result, the research community is called to perform a deep analysis of the steps already taken, and to re-think steps for the near and far future to capitalize on the lessons learned due to the pandemic. In this direction, on June 09th-11th, 2022, a group of twelve healthcare informatics researchers met in Rochester, MN, USA. This meeting was initiated by the Institute for Healthcare Informatics-IHI, and hosted by the Mayo Clinic. The goal of the meeting was to discuss and propose a research agenda for biomedical and health informatics for the next decade, in light of the changes and the lessons learned from the CoViD-19 pandemic. This article reports the main topics discussed and the conclusions reached. The intended readers of this paper, besides the biomedical and health informatics research community, are all those stakeholders in academia, industry, and government, who could benefit from the new research findings in biomedical and health informatics research. Indeed, research directions and social and policy implications are the main focus of the research agenda we propose, according to three levels: the care of individuals, the healthcare system view, and the population view
Spacial and temporal dynamics of the volume fraction of the colloidal particles inside a drying sessile drop
Using lubrication theory, drying processes of sessile colloidal droplets on a
solid substrate are studied. A simple model is proposed to describe temporal
dynamics both the shape of the drop and the volume fraction of the colloidal
particles inside the drop. The concentration dependence of the viscosity is
taken into account. It is shown that the final shapes of the drops depend on
both the initial volume fraction of the colloidal particles and the capillary
number. The results of our simulations are in a reasonable agreement with the
published experimental data. The computations for the drops of aqueous solution
of human serum albumin (HSA) are presented.Comment: Submitted to EPJE, 7 pages, 8 figure
Relation of gallbladder function and Helicobacter pylori infection to gastric mucosa inflammation in patients with symptomatic cholecystolithiasis
Background. Inflammatory alterations of the gastric mucosa are commonly caused by Helicobacter pylori (Hp) infection in patients with symptomatic gallstone disease. However, the additional pathogenetic role of an impaired gallbladder function leading to an increased alkaline duodenogastric reflux is controversially discussed. Aim:To investigate the relation of gallbladder function and Hp infection to gastric mucosa inflammation in patients with symptomatic gallstones prior to cholecystectomy. Patients: Seventy-three patients with symptomatic gallstones were studied by endoscopy and Hp testing. Methods: Gastritis classification was performed according to the updated Sydney System and gallbladder function was determined by total lipid concentration of gallbladder bile collected during mainly laparoscopic cholecystectomy. Results: Fifteen patients revealed no, 39 patients mild, and 19 moderate to marked gastritis. No significant differences for bile salts, phospholipids, cholesterol, or total lipids in gallbladder bile were found between these three groups of patients. However, while only 1 out of 54 (< 2%) patients with mild or no gastritis was found histologically positive for Hp, this infection could be detected in 14 (74%) out of 19 patients with moderate to marked gastritis. Conclusion: Moderate to marked gastric mucosa inflammation in gallstone patients is mainly caused by Hp infection, whereas gallbladder function is not related to the degree of gastritis. Thus, an increased alkaline duodenogastric reflux in gallstone patients seems to be of limited pathophysiological relevance. Copyright (c) 2006 S. Karger AG, Basel
Consequences of converting graded to action potentials upon neural information coding and energy efficiency
Information is encoded in neural circuits using both graded and action potentials, converting between them within single neurons and successive processing layers. This conversion is accompanied by information loss and a drop in energy efficiency. We investigate the biophysical causes of this loss of information and efficiency by comparing spiking neuron models, containing stochastic voltage-gated Na+ and K+ channels, with generator potential and graded potential models lacking voltage-gated Na+ channels. We identify three causes of information loss in the generator potential that are the by-product of action potential generation: (1) the voltage-gated Na+ channels necessary for action potential generation increase intrinsic noise and (2) introduce non-linearities, and (3) the finite duration of the action potential creates a ‘footprint’ in the generator potential that obscures incoming signals. These three processes reduce information rates by ~50% in generator potentials, to ~3 times that of spike trains. Both generator potentials and graded potentials consume almost an order of magnitude less energy per second than spike trains. Because of the lower information rates of generator potentials they are substantially less energy efficient than graded potentials. However, both are an order of magnitude more efficient than spike trains due to the higher energy costs and low information content of spikes, emphasizing that there is a two-fold cost of converting analogue to digital; information loss and cost inflation
Simple, Fast and Accurate Implementation of the Diffusion Approximation Algorithm for Stochastic Ion Channels with Multiple States
The phenomena that emerge from the interaction of the stochastic opening and
closing of ion channels (channel noise) with the non-linear neural dynamics are
essential to our understanding of the operation of the nervous system. The
effects that channel noise can have on neural dynamics are generally studied
using numerical simulations of stochastic models. Algorithms based on discrete
Markov Chains (MC) seem to be the most reliable and trustworthy, but even
optimized algorithms come with a non-negligible computational cost. Diffusion
Approximation (DA) methods use Stochastic Differential Equations (SDE) to
approximate the behavior of a number of MCs, considerably speeding up
simulation times. However, model comparisons have suggested that DA methods did
not lead to the same results as in MC modeling in terms of channel noise
statistics and effects on excitability. Recently, it was shown that the
difference arose because MCs were modeled with coupled activation subunits,
while the DA was modeled using uncoupled activation subunits. Implementations
of DA with coupled subunits, in the context of a specific kinetic scheme,
yielded similar results to MC. However, it remained unclear how to generalize
these implementations to different kinetic schemes, or whether they were faster
than MC algorithms. Additionally, a steady state approximation was used for the
stochastic terms, which, as we show here, can introduce significant
inaccuracies. We derived the SDE explicitly for any given ion channel kinetic
scheme. The resulting generic equations were surprisingly simple and
interpretable - allowing an easy and efficient DA implementation. The algorithm
was tested in a voltage clamp simulation and in two different current clamp
simulations, yielding the same results as MC modeling. Also, the simulation
efficiency of this DA method demonstrated considerable superiority over MC
methods.Comment: 32 text pages, 10 figures, 1 supplementary text + figur
- …