11 research outputs found

    Current practices in long-term video-EEG monitoring services: A survey among partners of the E-PILEPSY pilot network of reference for refractory epilepsy and epilepsy surgery.

    Get PDF
    The European Union-funded E-PILEPSY network aims to improve awareness of, and accessibility to, epilepsy surgery across Europe. In this study we assessed current clinical practices in epilepsy monitoring units (EMUs) in the participating centers. A 60-item web-based survey was distributed to 25 centers (27 EMUs) of the E-PILEPSY network across 22 European countries. The questionnaire was designed to evaluate the characteristics of EMUs, including organizational aspects, admission, and observation of patients, procedures performed, safety issues, cost, and reimbursement. Complete responses were received from all (100%) EMUs surveyed. Continuous observation of patients was performed in 22 (81%) EMUs during regular working hours, and in 17 EMUs (63%) outside of regular working hours. Fifteen (56%) EMUs requested a signed informed consent before admission. All EMUs performed tapering/withdrawal of antiepileptic drugs, 14 (52%) prior to admission to an EMU. Specific protocols on antiepileptic drugs (AED) tapering were available in four (15%) EMUs. Standardized Operating Procedures (SOP) for the treatment of seizure clusters and status epilepticus were available in 16 (59%). Safety measures implemented by EMUs were: alarm seizure buttons in 21 (78%), restricted patient's ambulation in 19 (70%), guard rails in 16 (59%), and specially designated bathrooms in 7 (26%). Average costs for one inpatient day in EMU ranged between 100 and 2200 Euros. This study shows a considerable diversity in the organization and practice patterns across European epilepsy monitoring units. The collected data may contribute to the development and implementation of evidence-based recommended practices in LTM services across Europe

    Diagnostic and prognostic value of noninvasive long-term video-electroencephalographic monitoring in epilepsy surgery: A systematic review and meta-analysis from the E-PILEPSY consortium

    Get PDF
    OBJECTIVE: The European Union–funded E‐PILEPSY network (now continuing within the European Reference Network for rare and complex epilepsies [EpiCARE]) aims to harmonize and optimize presurgical diagnostic procedures by creating and implementing evidence‐based guidelines across Europe. The present study evaluates the current evidence on the diagnostic accuracy of long‐term video‐electroencephalographic monitoring (LTM) in identifying the epileptogenic zone in epilepsy surgery candidates. METHODS: MEDLINE, Embase, CENTRAL, and ClinicalTrials.gov were searched for relevant articles. First, we used random‐effects meta‐analytical models to calculate pooled estimates of sensitivity and specificity with respect to postsurgical seizure freedom. In a second phase, we analyzed individual patient data in an exploratory fashion, assessing diagnostic accuracy within lesional and nonlesional temporal lobe epilepsy (TLE) and extratemporal lobe epilepsy (ETLE) patients. We also evaluated seizure freedom rate in the presence of “localizing” or “nonlocalizing” LTM within each group. The quality of evidence was assessed using the QUADAS‐2 tool and the GRADE approach. RESULTS: Ninety‐four studies were eligible. Forty‐four were included in sensitivity meta‐analysis and 34 in specificity meta‐analysis. Pooled sensitivity was 0.70 (95% confidence interval [CI] = 0.60‐0.80) and specificity was 0.40 (95% CI = 0.27‐0.54). Subgroup analysis was based on individual data of 534 patients (41% men). In lesional TLE patients, sensitivity was 0.85 (95% CI = 0.81‐0.89) and specificity was −0.19 (95% CI = 0.13‐0.28). In lesional ETLE patients, a sensitivity of 0.47 (95% CI = 0.36‐0.58) and specificity of 0.35 (95% CI = 0.21‐0.53) were observed. In lesional TLE, if LTM was localizing and concordant with resection site, the seizure freedom rate was 247 of 333 (74%), whereas in lesional ETLE it was 34 of 56 (61%). The quality of evidence was assigned as “very low.” SIGNIFICANCE: Long‐term video‐electroencephalographic monitoring is associated with moderate sensitivity and low specificity in identification of the epileptogenic zone. Sensitivity is remarkably higher in lesional TLE compared to lesional ETLE. Substantial heterogeneity across the studies indicates the need for improved design and quality of reporting

    Data of the Georadar Exploration of the Cave Satsurbliya

    No full text
    საწურბლიას კარსტული მღვიმის ფსკერზე განთავსებული რკინაბეტონის პლატფორმის პერიმეტრის გასწვრივ გეორადიოლკაციური გამოკვლევა ჩატარდა 5 გეორადიოლოკაციურ პროფილზე. შედეგად დადგინდა რომ შესწავლილ ტერიტორიაზე არ აღინიშნება გაბარიტული სიღრუვეები , რომლებიც შეიძლება პლატფორმის მიმდებარე სადგომ არეს ასუსტებდეს და მის მდგრადობას რეალურ საფრთეს უქმნიდეს. გეორადიოლოკაცია, კარსტული ღვიმე, გეორადიოლოკაციური პროფილები.Georadar research on the perimeter of the reinforced concrete platform at the bottom of the karst cave Satsurblia was conducted using 5 georadar tracking profiles. As a result, it was found that in the study area there are no overall underground cavities that can weaken the base of the platform and create a threat to its stability

    Current standards of neuropsychological assessment in epilepsy surgery centers across Europe.

    Get PDF
    We explored the current practice with respect to the neuropsychological assessment of surgical epilepsy patients in European epilepsy centers, with the aim of harmonizing and establishing common standards. Twenty-six epilepsy centers and members of "E-PILEPSY" (a European pilot network of reference centers in refractory epilepsy and epilepsy surgery), were asked to report the status of neuropsychological assessment in adults and children via two different surveys. There was a consensus among these centers regarding the role of neuropsychology in the presurgical workup. Strong agreement was found on indications (localization, epileptic dysfunctions, adverse drugs effects, and postoperative monitoring) and the domains to be evaluated (memory, attention, executive functions, language, visuospatial skills, intelligence, depression, anxiety, and quality of life). Although 186 different tests are in use throughout these European centers, a core group of tests reflecting a moderate level of agreement could be discerned. Variability exists with regard to indications, protocols, and paradigms for the assessment of hemispheric language dominance. For the tests in use, little published evidence of clinical validity in epilepsy was provided. Participants in the survey reported a need for improvement concerning the validity of the tests, tools for the assessment of everyday functioning and accelerated forgetting, national norms, and test co-normalization. Based on the present survey, we documented a consensus regarding the indications and principles of neuropsychological testing. Despite the variety of tests in use, the survey indicated that there may be a core set of tests chosen based on experience, as well as on published evidence. By combining these findings with the results of an ongoing systematic literature review, we aim for a battery that can be recommended for the use across epilepsy surgical centers in Europe

    Current use of imaging and electromagnetic source localization procedures in epilepsy surgery centers across Europe.

    Get PDF
    OBJECTIVE: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. METHODS: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. RESULTS: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. SIGNIFICANCE: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for high-quality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods
    corecore