539 research outputs found

    Isolation and purification of Cu-free methanobactin from Methylosinus trichosporium OB3b

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The isolation of highly pure copper-free methanobactin is a prerequisite for the investigation of the biogeochemical functions of this chalkophore molecule produced by methane oxidizing bacteria. Here, we report a purification method for methanobactin from <it>Methylosinus trichosporium </it>OB3b cultures based on reversed-phase HPLC fractionation used in combination with a previously reported resin extraction. HPLC eluent fractions of the resin extracted product were collected and characterized with UV-vis, FT-IR, and C-1s NEXAFS spectroscopy, as well as with elemental analysis and ESI-MS.</p> <p>Results</p> <p>The results showed that numerous compounds other than methanobactin were present in the isolate obtained with resin extraction. Molar C/N ratios, mass spectrometry measurements, and UV-vis spectra indicated that methanobactin was only present in one of the HPLC fractions. On a mass basis, methanobactin carbon contributed only 32% to the total organic carbon isolated with resin extraction. Our spectroscopic results implied that besides methanobactin, the organic compounds in the resin extract comprised breakdown products of methanobactin as well as polysaccharide-like substances.</p> <p>Conclusion</p> <p>Our results demonstrate that a purification step is indispensable in addition to resin extraction in order to obtain pure methanobactin. The proposed HPLC purification procedure is suitable for semi-preparative work and provides copper-free methanobactin.</p

    MODEM: a comprehensive approach to modelling outcome and costs impacts of interventions for dementia. Protocol paper

    Get PDF
    Background The MODEM project (A comprehensive approach to MODelling outcome and costs impacts of interventions for DEMentia) explores how changes in arrangements for the future treatment and care of people living with dementia, and support for family and other unpaid carers, could result in better outcomes and more efficient use of resources. Methods MODEM starts with a systematic mapping of the literature on effective and (potentially) cost-effective interventions in dementia care. Those findings, as well as data from a cohort, will then be used to model the quality of life and cost impacts of making these evidence-based interventions more widely available in England over the period from now to 2040. Modelling will use a suite of models, combining microsimulation and macrosimulation methods, modelling the costs and outcomes of care, both for an individual over the life-course from the point of dementia diagnosis, and for individuals and England as a whole in a particular year. Project outputs will include an online Dementia Evidence Toolkit, making evidence summaries and a literature database available free to anyone, papers in academic journals and other written outputs, and a MODEM Legacy Model, which will enable local commissioners of services to apply the model to their own populations. Discussion Modelling the effects of evidence-based cost-effective interventions and making this information widely available has the potential to improve the health and quality of life both of people with dementia and their carers, while ensuring that resources are used efficiently

    The intertropical convergence zone modulates intense hurricane strikes on the western North Atlantic margin

    Get PDF
    © The Author(s), 2016. This article is distributed under the terms of the Creative Commons Attribution License. The definitive version was published in Scientific Reports 6 (2016): 21728, doi:10.1038/srep21728Most Atlantic hurricanes form in the Main Development Region between 9°N to 20°N along the northern edge of the Intertropical Convergence Zone (ITCZ). Previous research has suggested that meridional shifts in the ITCZ position on geologic timescales can modulate hurricane activity, but continuous and long-term storm records are needed from multiple sites to assess this hypothesis. Here we present a 3000 year record of intense hurricane strikes in the northern Bahamas (Abaco Island) based on overwash deposits in a coastal sinkhole, which indicates that the ITCZ has likely helped modulate intense hurricane strikes on the western North Atlantic margin on millennial to centennial-scales. The new reconstruction closely matches a previous reconstruction from Puerto Rico, and documents a period of elevated intense hurricane activity on the western North Atlantic margin from 2500 to 1000 years ago when paleo precipitation proxies suggest that the ITCZ occupied a more northern position. Considering that anthropogenic warming is predicted to be focused in the northern hemisphere in the coming century, these results provide a prehistoric analog that an attendant northern ITCZ shift in the future may again return the western North Atlantic margin to an active hurricane interval.This research was supported by NSF Awards: OCE-1519578, OCE-1356708, BCS-1118340

    Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM

    Get PDF
    BACKGROUND: Positron Emission Tomography (PET), Computed Tomography (CT), PET/CT and Single Photon Emission Tomography (SPECT) are non-invasive imaging tools used for creating two dimensional (2D) cross section images of three dimensional (3D) objects. PET and SPECT have the potential of providing functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules, whereas CT visualizes X-ray density in tissues in the body. PET/CT provides fused images representing both functional and anatomical information with better precision in localization than PET alone. Images generated by these types of techniques are generally noisy, thereby impairing the imaging potential and affecting the precision in quantitative values derived from the images. It is crucial to explore and understand the properties of noise in these imaging techniques. Here we used autocorrelation function (ACF) specifically to describe noise correlation and its non-isotropic behaviour in experimentally generated images of PET, CT, PET/CT and SPECT. METHODS: Experiments were performed using phantoms with different shapes. In PET and PET/CT studies, data were acquired in 2D acquisition mode and reconstructed by both analytical filter back projection (FBP) and iterative, ordered subsets expectation maximisation (OSEM) methods. In the PET/CT studies, different magnitudes of X-ray dose in the transmission were employed by using different mA settings for the X-ray tube. In the CT studies, data were acquired using different slice thickness with and without applied dose reduction function and the images were reconstructed by FBP. SPECT studies were performed in 2D, reconstructed using FBP and OSEM, using post 3D filtering. ACF images were generated from the primary images, and profiles across the ACF images were used to describe the noise correlation in different directions. The variance of noise across the images was visualised as images and with profiles across these images. RESULTS: The most important finding was that the pattern of noise correlation is rotation symmetric or isotropic, independent of object shape in PET and PET/CT images reconstructed using the iterative method. This is, however, not the case in FBP images when the shape of phantom is not circular. Also CT images reconstructed using FBP show the same non-isotropic pattern independent of slice thickness and utilization of care dose function. SPECT images show an isotropic correlation of the noise independent of object shape or applied reconstruction algorithm. Noise in PET/CT images was identical independent of the applied X-ray dose in the transmission part (CT), indicating that the noise from transmission with the applied doses does not propagate into the PET images showing that the noise from the emission part is dominant. The results indicate that in human studies it is possible to utilize a low dose in transmission part while maintaining the noise behaviour and the quality of the images. CONCLUSION: The combined effect of noise correlation for asymmetric objects and a varying noise variance across the image field significantly complicates the interpretation of the images when statistical methods are used, such as with statistical estimates of precision in average values, use of statistical parametric mapping methods and principal component analysis. Hence it is recommended that iterative reconstruction methods are used for such applications. However, it is possible to calculate the noise analytically in images reconstructed by FBP, while it is not possible to do the same calculation in images reconstructed by iterative methods. Therefore for performing statistical methods of analysis which depend on knowing the noise, FBP would be preferred

    Biphasic pulses enhance bleomycin efficacy in a spontaneous canine genital tumor model of chemoresistance: Sticker sarcoma

    Get PDF
    Sticker's sarcoma (also known as transmissible venereal tumor) is a horizontally transmitted neoplasm of the dog, that is passed with coitus. It is a locally aggressive tumor with a low tendency to metastatic spread. The most common locations are the genitals, the nose, the perianal area. Standard treatment consists with chemotherapy with vincristine, however other therapies such as, cryotherapy, immunotherapy or, in selected cases, radiation therapy, have been reported. In this article we describe the outcome of a small cohort of canine patients, with chemotherapy resistant transmissible venereal tumor (TVT), treated with bleomycin selectively driven by trains of biphasic pulses (electrochemotherapy). Three canine patients, with refractory TVT, entered the study and received two sessions of ECT under sedation. The pets had local injection of bleomycin at the concentration of 1.5 mg/ml and five minutes after the chemotherapy, trains of 8 biphasic electric pulses lasting 50 + 50 μs each, with 1 ms interpulse intervals, were delivered by means of modified caliper or, for difficult districts, through paired needle electrode. All the patients responded to the treatment and are still in remission at different times. Electrochemotherapy appears as a safe and efficacious modality for the treatment of TVT and warrants further investigations

    Evidence for a Prepore Stage in the Action of Clostridium perfringens Epsilon Toxin

    Get PDF
    Clostridium perfringens epsilon toxin (ETX) rapidly kills MDCK II cells at 37°C, but not 4°C. The current study shows that, in MDCK II cells, ETX binds and forms an oligomeric complex equally well at 37°C and 4°C but only forms a pore at 37°C. However, the complex formed in MDCK cells treated with ETX at 4°C has the potential to form an active pore, since shifting those cells to 37°C results in rapid cytotoxicity. Those results suggested that the block in pore formation at 4°C involves temperature-related trapping of ETX in a prepore intermediate on the MDCK II cell plasma membrane surface. Evidence supporting this hypothesis was obtained when the ETX complex in MDCK II cells was shown to be more susceptible to pronase degradation when formed at 4°C vs. 37°C; this result is consistent with ETX complex formed at 4°C remaining present in an exposed prepore on the membrane surface, while the ETX prepore complex formed at 37°C is unaccessible to pronase because it has inserted into the plasma membrane to form an active pore. In addition, the ETX complex rapidly dissociated from MDCK II cells at 4°C, but not 37°C; this result is consistent with the ETX complex being resistant to dissociation at 37°C because it has inserted into membranes, while the ETX prepore readily dissociates from cells at 4°C because it remains on the membrane surface. These results support the identification of a prepore stage in ETX action and suggest a revised model for ETX cytotoxicity, i) ETX binds to an unidentified receptor, ii) ETX oligomerizes into a prepore on the membrane surface, and iii) the prepore inserts into membranes, in a temperature-sensitive manner, to form an active pore

    Effects of climate and snow depth on Bromus tectorum population dynamics at high elevation

    Get PDF
    Invasive plants are thought to be especially capable of range shifts or expansion in response to climate change due to high dispersal and colonization abilities. Although highly invasive throughout the Intermountain West, the presence and impact of the grass Bromus tectorum has been limited at higher elevations in the eastern Sierra Nevada, potentially due to extreme wintertime conditions. However, climate models project an upward elevational shift of climate regimes in the Sierra Nevada that could favor B. tectorum expansion. This research specifically examined the effects of experimental snow depth manipulations and interannual climate variability over 5 years on B. tectorum populations at high elevation (2,175 m). Experimentally-increased snow depth had an effect on phenology and biomass, but no effect on individual fecundity. Instead an experimentally-increased snowpack inhibited population growth in 1 year by reducing seedling emergence and early survival. A similar negative effect of increased snow was observed 2 years later. However, a strong negative effect on B. tectorum was also associated with a naturally low-snow winter, when seedling emergence was reduced by 86%. Across 5 years, winters with greater snow cover and a slower accumulation of degree-days coincided with higher B. tectorum seedling density and population growth. Thus, we observed negative effects associated with both experimentally-increased and naturally-decreased snowpacks. It is likely that the effect of snow at high elevation is nonlinear and differs from lower elevations where wintertime germination can be favorable. Additionally, we observed a doubling of population size in 1 year, which is alarming at this elevation

    Assessment of ePrescription quality: an observational study at three mail-order pharmacies

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The introduction of electronic transfer of prescriptions (ETP) or ePrescriptions in ambulatory health care has been suggested to have a positive impact on the prescribing and dispensing processes. Thereby, implying that ePrescribing can improve safety, quality, efficiency, and cost-effectiveness. In December 2007, 68% of all new prescriptions were transferred electronically in Sweden. The aim of the present study was to assess the quality of ePrescriptions by comparing the proportions of ePrescriptions and non-electronic prescriptions necessitating a clarification contact (correction, completion or change) with the prescriber at the time of dispensing.</p> <p>Methods</p> <p>A direct observational study was performed at three Swedish mail-order pharmacies which were known to dispense a large proportion of ePrescriptions (38–75%). Data were gathered on all ePrescriptions dispensed at these pharmacies over a three week period in February 2006. All clarification contacts with prescribers were included in the study and were classified and assessed in comparison with all drug prescriptions dispensed at the same pharmacies over the specified period.</p> <p>Results</p> <p>Of the 31225 prescriptions dispensed during the study period, clarification contacts were made for 2.0% (147/7532) of new ePrescriptions and 1.2% (79/6833) of new non-electronic prescriptions. This represented a relative risk (RR) of 1.7 (95% CI 1.3–2.2) for new ePrescriptions compared to new non-electronic prescriptions. The increased RR was mainly due to 'Dosage and directions for use', which had an RR of 7.6 (95% CI 2.8–20.4) when compared to other clarification contacts. In all, 89.5% of the suggested pharmacist interventions were accepted by the prescriber, 77.7% (192/247) as suggested and an additional 11.7% (29/247) after a modification during contact with the prescriber.</p> <p>Conclusion</p> <p>The increased proportion of prescriptions necessitating a clarification contact for new ePrescriptions compared to new non-electronic prescriptions indicates the need for an increased focus on quality aspects in ePrescribing deployment. ETP technology should be developed towards a two-way communication between the prescriber and the pharmacist with automated checks of missing, inaccurate, or ambiguous information. This would enhance safety and quality for the patient and also improve efficiency and cost-effectiveness within the health care system.</p
    corecore