654 research outputs found

    Uncertainties in constraining low-energy constants from 3^3H β\beta decay

    Full text link
    We discuss the uncertainties in constraining low-energy constants of chiral effective field theory from 3^3H β\beta decay. The half-life is very precisely known, so that the Gamow-Teller matrix element has been used to fit the coupling cDc_D of the axial-vector current to a short-range two-nucleon pair. Because the same coupling also describes the leading one-pion-exchange three-nucleon force, this in principle provides a very constraining fit, uncorrelated with the 3^3H binding energy fit used to constrain another low-energy coupling in three-nucleon forces. However, so far such 3^3H half-life fits have only been performed at a fixed cutoff value. We show that the cutoff dependence due to the regulators in the axial-vector two-body current can significantly affect the Gamow-Teller matrix elements and consequently also the extracted values for the cDc_D coupling constant. The degree of the cutoff dependence is correlated with the softness of the employed NN interaction. As a result, present three-nucleon forces based on a fit to 3^3H β\beta decay underestimate the uncertainty in cDc_D. We explore a range of cDc_D values that is compatible within cutoff variation with the experimental 3^3H half-life and estimate the resulting uncertainties for many-body systems by performing calculations of symmetric nuclear matter.Comment: 9 pages, 11 figures, published version, includes Erratum, which corrects Figs. 2-6 due to the incorrect c_D relation between 3N forces and two-body currents use

    The Dynamics of Disagreement

    Get PDF
    In this paper, we infer how the estimates of firm value by “optimists” and “pessimists” evolve in response to information shocks. Specifically, we examine returns and disagreement measures for portfolios of short-sale-constrained stocks that have experienced large gains or large losses. Our analysis suggests the presence of two groups, one of which overreacts to new information and remains biased over about 5 years, and a second group, which underreacts and whose expectations are unbiased after about 1 year. Our results have implications for the belief dynamics that underlie the momentum and long-term reversal effect

    Fluid Interactions That Enable Stealth Predation by the Upstream-Foraging Hydromedusa \u3cem\u3eCraspedacusta sowerbyi\u3c/em\u3e

    Get PDF
    Unlike most medusae that forage with tentacles trailing behind their bells, several species forage upstream of their bells using aborally located tentacles. It has been hypothesized that these medusae forage as stealth predators by placing their tentacles in more quiescent regions of flow around their bells. Consequently, they are able to capture highly mobile, sensitive prey. We used digital particle image velocimetry (DPIV) to quantitatively characterize the flow field around Craspedacusta sowerbyi, a freshwater upstream-foraging hydromedusa, to evaluate the mechanics of its stealth predation. We found that fluid velocities were minimal in front and along the sides of the bell where the tentacles are located. As a result, the deformation rates in the regions where the tentacles are located were low, below the threshold rates required to elicit an escape response in several species of copepods. Estimates of their encounter volume rates were examined on the basis of flow past the tentacles, and trade-offs associated with tentacle characteristics were evaluated

    Cold heteromolecular dipolar collisions

    Get PDF
    We present the first experimental observation of cold collisions between two different species of neutral polar molecules, each prepared in a single internal quantum state. Combining for the first time the techniques of Stark deceleration, magnetic trapping, and cryogenic buffer gas cooling allows the enhancement of molecular interaction time by 105^5. This has enabled an absolute measurement of the total trap loss cross sections between OH and ND3_3 at a mean collision energy of 3.6 cm1^{-1} (5 K). Due to the dipolar interaction, the total cross section increases upon application of an external polarizing electric field. Cross sections computed from \emph{ab initio} potential energy surfaces are in excellent agreement with the measured value at zero external electric field. The theory presented here represents the first such analysis of collisions between a 2Π^2\Pi radical and a closed-shell polyatomic molecule.Comment: 7 pages, 5 figure

    Utility of the Cortical Thickness of the Distal Radius as a Predictor of Distal-Radius Bone Density

    Get PDF
    Background: Bone density is an important factor in the management of fractures of the distal radius. Objectives: The aim of this study was to establish whether standard anteroposterior (AP) radiographs would provide the attending physician with a prediction of bone density. Patients and Methods: Six pairs of human cadaveric radii were harvested. The mean donor age was 74 years. Standardized AP radiographs were taken of the radii. The outside diameter and the inside diameter of the cortical shell at the metaphyseal / diaphyseal junction were measured and their ratio was calculated. Dual-energy x-ray absorptiometry (DXA) was used to obtain the bone mineral density (BMD) of the distal parts of the radii. The correlation of the BMD values with these ratios was studied. Results: The mean BMD was 0.559 (SD = 0.236) g / cm2. The mean outside diameter/inside diameter ratio was 1.24 (SD = 0.013); the ratio significantly correlated with the total BMD (P = 0.001; R2 = 0.710). In the BMD subregions, the correlation was also significant. Conclusions: The outside diameter/inside diameter ratio at the metaphyseal/diaphyseal junction of the distal radius on AP radiographs is suitable for use as a predictor of distal-radius bone density. Further studies should be performed, and clinical utility evaluated

    Severe pneumonia due to Parachlamydia acanthamoebae following intranasal inoculation: a mice model.

    Get PDF
    Parachlamydia acanthamoebae is an obligate intracellular bacterium naturally infecting free-living amoebae. The role of this bacterium as an agent of pneumonia is suggested by sero-epidemiological studies and molecular surveys. Furthermore, P. acanthamoebae may escape macrophages microbicidal effectors. Recently, we demonstrated that intratracheal inoculation of P. acanthamoebae induced pneumonia in 100% of infected mice. However, the intratracheal route of infection is not the natural way of infection and we therefore developed an intranasal murine model. Mice inoculated with P. acanthamoebae by intranasal inoculation lost 18% of their weight up to 8 days post-inoculation. All mice presented histological signs of pneumonia at day 2, 4, 7, and 10 post-inoculation, whereas no control mice harboured signs of pneumonia. A 5-fold increase in bacterial load was observed from day 0 to day 4 post-inoculation. Lungs of inoculated mice were positive by Parachlamydia-specific immunohistochemistry 4 days post-inoculation, and P. acanthamoebae were localized within macrophages. Thus, we demonstrated that P. acanthamoebae induce a severe pneumonia in mice. This animal model (i) further supports the role of P. acanthamoebae as an agent of pneumonia, confirming the third Koch postulate, and (ii) identified alveolar macrophages as one of the initial cells where P. acanthamoebae is localized following infection

    Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures

    Get PDF
    Background: Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. On the other hand, intra-articular screw misplacements will promote osteoarthritis, while the penetration of the contralateral bone surface may result in tendon irritations and ruptures. The intraoperative control of fracture reduction and implant positioning is limited in the common postero-anterior and true lateral two-dimensional (2D)-fluoroscopic views. Therefore, additional 2D-fluoroscopic views in different projections and intraoperative three-dimensional (3D) fluoroscopy were recently reported. Nevertheless, their utility has issued controversies. Objectives: The following questions should be answered in this study; 1) Are the additional tangential view and the intraoperative 3D fluoroscopy useful in the clinical routine to detect persistent fracture dislocations and screw misplacements, to prevent revision surgery? 2) Which is the most dangerous plate hole for screw misplacement? Patients and Methods: A total of 48 patients (36 females and 13 males) with 49 unstable distal radius fractures (22 x 23 A; 2 x 23 B, and 25 x 23 C) were treated with a 2.4 mm variable angle LCP Two-Column volar distal radius plate (Synthes GmbH, Oberdorf, Switzerland) during a 10-month period. After final fixation, according to the manufactures' technique guide and control of implant placement in the two common perpendicular 2D-fluoroscopic images (postero-anterior and true lateral), an additional tangential view and intraoperative 3D fluoroscopic scan were performed to control the anatomic fracture reduction and screw placements. Intraoperative revision rates due to screw misplacements (intra-articular or overlength) were evaluated. Additionally, the number of surgeons, time and radiation-exposure, for each step of the operating procedure, were recorded. Results: In the standard 2D-fluoroscopic views (postero-anterior and true lateral projection), 22 screw misplacements of 232 inserted screws were not detected. Based on the additional tangential view, 12 screws were exchanged, followed by further 10 screws after performing the 3D fluoroscopic scan. The most lateral screw position had the highest risk for screw misplacement (accounting for 45.5% of all exchanged screws). The mean number of images for the tangential view was 3 ± 2.5 images. The mean surgical time was extended by 10.02 ± 3.82 minutes for the 3D fluoroscopic scan. An additional radiation exposure of 4.4 ± 4.5seconds, with a dose area product of 39.2 ± 14.5 cGy/cm2 were necessary for the tangential view and 54.4 ± 20.9 seconds with a dose area product of 2.1 ± 2.2 cGy/cm2, for the 3D fluoroscopic scan. Conclusions: We recommend the additional 2D-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortical surface of the distal radius, predominantly observed for the most lateral screw position. The use of intraoperative 3D fluoroscopy did not become accepted in our clinical routine, due to the technical demanding and time consuming procedure, with a limited image quality so far

    Information on antiprotonic atoms and the nuclear periphery from the PS209 experiment

    Full text link
    In the PS209 experiments at CERN two kinds of measurements were performed: the in-beam measurement of X-rays from antiprotonic atoms and the radiochemical, off-line determination of the yield of annihilation products with mass number A_t -1 (less by 1 than the target mass). Both methods give observables which allows to study the peripheral matter density composition and distribution.Comment: LaTeX (espcrc1 style), 6 pages, 3 EPS figures, 1 table, Proceedings of the Sixth Biennal Conference on Low-Energy Antiproton Physics LEAP 2000, Venice, Ital
    corecore