7 research outputs found

    Breast cancer screening in the Czech Republic: time trends in performance indicators during the first seven years of the organised programme

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Czech Breast Cancer Screening Programme (CBCSP) was initiated in September 2002 by establishing a network of accredited centres. The aim of this article is to describe progress in the programme quality over time after the inception of the organised programme.</p> <p>Methods</p> <p>The CBCSP is monitored using an information system consisting of three principal components: 1) the national cancer registry, 2) a screening registry collecting data on all screening examinations, further assessments and final diagnoses at accredited programme centres, and 3) administrative databases of healthcare payers. Key performance indicators from the European Guidelines have been adopted for continuous monitoring.</p> <p>Results</p> <p>Breast cancer incidence in the Czech Republic has steadily been increasing, however with a growing proportion of less advanced stages. The mortality rate has recently stabilised. The screening registry includes 2,083,285 records on screening episodes between 2002 and 2008. In 2007-2008, 51% of eligible women aged 45-69 were screened. In 2008, the detection rates were 6.1 and 3.7 per 1,000 women in initial and subsequent screening respectively. Corresponding recall rates are 3.9% and 2.2%, however, it is necessary to pay attention to further assessment performed during the screening visits. Benign to malignant open biopsy ratio was 0.1. Of invasive cases detected in screening, 35.6% was less than 10 mm in diameter. Values of early performance indicators, as measured by both crude and standardized estimates, are generally improving and fulfil desirable targets set by European Guidelines.</p> <p>Conclusions</p> <p>Mammography screening in the Czech Republic underwent successful transformation from opportunistic prevention to an organised programme. Values of early indicators confirm continuous improvement in different aspects of process quality. Further stimulation of participation through invitation system is necessary to exploit the full potential of screening mammography at the population level.</p

    Experimental investigation of stabilization of flowing water temperature with a water-PCM heat exchanger

    No full text
    Experiments have been carried out in order to investigate the stabilization of water temperature with a water-PCM heat exchanger. The water-PCM heat exchanger was of a rather simple design. It was a round tube, through which the water flowed, surrounded with an annular layer of PCM. The heat exchanger was divided into one meter long segments (modules) and the water temperature was monitored at the outlet of each of the segments. A paraffin-based PCM with the melting temperature of 42 °C was used in the experiments. The experimental set-up consisted of two water reservoirs kept at different temperatures, the water-PCM heat exchanger, PC controlled valves and a data acquisition system. As the first step a response to a step change in the water temperature at the inlet of the heat exchanger was investigated. Subsequently, a series of experiments with a square wave change of temperature at the inlet of the exchanger were carried out. The square wave temperature profile was achieved by periodic switching between the two water reservoirs. Several amplitudes and periods of temperature square wave were used. The results of experiments show that a water-PCM heat exchanger can effectively be used to stabilize the flowing water temperature when the inlet temperature changes are around the melting range of the PCM
    corecore