23 research outputs found

    Evaluation of serological diagnostic test systems assessing the immune response to Japanese encephalitis vaccination.

    Get PDF
    A new commercial anti-Japanese encephalitis virus IgM and IgG indirect immunofluorescence test (IIFT) was evaluated for the detection of the humoral immune response after Japanese encephalitis vaccination. The IgM IIFT was compared to two IgM capture ELISAs and the IgG IIFT was analysed in comparison to a plaque reduction neutralization test (PRNT50) and an IgG ELISA. Moreover, the course of the immune reaction after vaccination with an inactivated JEV vaccine was examined. For the present study 300 serum samples from different blood withdrawals from 100 persons vaccinated against Japanese encephalitis were used. For the IgM evaluation, altogether 78 PRNT50 positive samples taken 7 to 56 days after vaccination and 78 PRNT50 negative sera were analyzed with the Euroimmun anti-JEV IgM IIFT, the Panbio Japanese Encephalitis – Dengue IgM Combo ELISA and the InBios JE Detect IgM capture ELISA. For the IgG evaluation, 100 sera taken 56 days after vaccination and 100 corresponding sera taken before vaccination were tested in the PRNT50, the Euroimmun anti-JEV IgG IIFT, and the InBios JE Detect IgG ELISA. The Euroimmun IgM IIFT showed in comparison to the Panbio ELISA a specificity of 95% and a sensitivity of 86%. With respect to the InBios ELISA, the values were 100% and 83.9%, respectively. The analysis of the Euroimmun IgG IIFT performance and the PRNT50 results demonstrated a specificity of 100% and a sensitivity of 93.8%, whereas it was not possible to detect more than 6.6% of the PRNT50 positive sera as positive with the InBios JE Detect IgG ELISA. Thus, the IIFT is a valuable alternative to the established methods in detecting anti-JEV antibodies after vaccination in travellers and it might prove useful for the diagnosis of acutely infected persons

    Landiolol in patients with septic shock resident in an intensive care unit (LANDI-SEP): study protocol for a randomized controlled trial

    Get PDF
    In patients with septic shock, the presence of an elevated heart rate (HR) after fluid resuscitation marks a subgroup of patients with a particularly poor prognosis. Several studies have shown that HR control in this population is safe and can potentially improve outcomes. However, all were conducted in a single-center setting. The aim of this multicenter study is to demonstrate that administration of the highly beta1-selective and ultrashort-acting beta blocker landiolol in patients with septic shock and persistent tachycardia (HR ae 95 beats per minute [bpm]) is effective in reducing and maintaining HR without increasing vasopressor requirements. A phase IV, multicenter, prospective, randomized, open-label, controlled study is being conducted. The study will enroll a total of 200 patients with septic shock as defined by The Third International Consensus Definitions for Sepsis and Septic Shock criteria and tachycardia (HR ae 95 bpm) despite a hemodynamic optimization period of 24-36 h. Patients are randomized (1:1) to receive either standard treatment (according to the Surviving Sepsis Campaign Guidelines 2016) and continuous landiolol infusion to reach a target HR of 80-94 bpm or standard treatment alone. The primary endpoint is HR response (HR 80-94 bpm), the maintenance thereof, and the absence of increased vasopressor requirements during the first 24 h after initiating treatment. Despite recent studies, the role of beta blockers in the treatment of patients with septic shock remains unclear. This study will investigate whether HR control using landiolol is safe, feasible, and effective, and further enhance the understanding of beta blockade in patients with septic shock

    Pharmacokinetics of a Novel Anagrelide ExtendedRelease Formulation in Healthy Subjects: Food Intake and Comparison With a Reference Product

    No full text
    Anagrelide is an established therapy for essential thrombocythemia. Common adverse effects have been linked to peak plasma concentrations of anagrelide and its 3OH metabolite. Our study was performed to investigate the pharmacokinetics (PK) of a novel anagrelide extendedrelease (AER) formulation and its active metabolites. Thirty healthy volunteers were randomized to receive either 2 mg AER (under fasting and fed conditions) or 2 mg commercially available reference product (CARP) in an openlabel, 3way crossover trial with washout periods of 6 days. Plasma concentrations of anagrelide and its active metabolites were assessed by tandem mass spectrometry. The PK differed significantly between all treatment periods. Bioavailability of AER was 55% of the CARP under fasting conditions and 60% under fed conditions. Cmax, AUCt, and AUC were significantly higher and Tmax and T1/2 were significantly shorter after the CARP compared with AER. Food had a significant impact on the PK of AER, increasing the Cmax and AUCt while reducing the T1/2, plateau, and mean residence time. Both formulations were well tolerated, with a trend toward more frequently occurring adverse events after the CARP. The PK of AER and the CARP differed significantly in all parameters. Food enhanced the bioavailability of AER.(VLID)481534

    Clearance of low levels of HCV viremia in the absence of a strong adaptive immune response

    Get PDF
    <p>Abstract</p> <p>Spontaneous clearance of hepatitis C virus (HCV) has frequently been associated with the presence of HCV-specific cellular immunity. However, there had been also reports in chimpanzees demonstrating clearance of HCV-viremia in the absence of significant levels of detectable HCV-specific cellular immune responses. We here report seven asymptomatic acute hepatitis C cases with peak HCV-RNA levels between 300 and 100.000 copies/ml who all cleared HCV-RNA spontaneously. Patients were identified by a systematic screening of 1176 consecutive new incoming offenders in a German young offender institution. Four of the seven patients never developed anti-HCV antibodies and had normal ALT levels throughout follow-up. Transient weak HCV-specific CD4+ T cell responses were detectable in five individuals which did not differ in strength and breadth from age- and sex-matched patients with chronic hepatitis C and long-term recovered patients. In contrast, HCV-specific MHC-class-I-tetramer-positive cells were found in 3 of 4 HLA-A2-positive patients. Thus, these cases highlight that clearance of low levels of HCV viremia is possible in the absence of a strong adaptive immune response which might explain the low seroconversion rate after occupational exposure to HCV.</p

    Monolith affinity chromatography for the rapid quantification of a single-chain variable fragment immunotoxin

    No full text
    We developed a novel analytical method for concentration determination of tandem single-chain antibody diphtheria toxin (immunotoxin). The method is based on polymethacrylate monoliths with Protein L ligands as the binding moiety. Different buffers were tested for elution of the Protein L-bound immunotoxin and 4.5 M guanidinium hydrochloride performed best. We optimized the elution conditions and the method sequence resulting in a fast and robust method with a runtime <10 min. Fast determination of immunotoxin is critical if any process decisions rely on this data. We determined method performance and a lower limit of detection of 27 ÎŒg/mL and a lower limit of quantification of 90 ÎŒg/mL was achieved. The validity of the method in terms of residual analysis, precision, and repeatability was proven in a range from 100 to 375 ÎŒg/mL. The short runtime and ease of use of a high-performance liquid chromatography method is especially useful for a process analytical tool approach. Bioprocesses related to immunotoxin where fermentation or other process parameters can be adjusted in accordance to the immunotoxin levels will be benefited from this method to achieve the highest possible purity and productivity

    Biochemical, virological and immunological course of acute hepatitis C in asymptomatic patients with spontaneous clearance: patients with spontaneous clearance in the absence of anti-HCV

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Clearance of low levels of HCV viremia in the absence of a strong adaptive immune response"</p><p>http://www.virologyj.com/content/4/1/58</p><p>Virology Journal 2007;4():58-58.</p><p>Published online 11 Jun 2007</p><p>PMCID:PMC1914341.</p><p></p> HCV-RNA levels, ALT levels and T cell responses are shown. Coloured bars show the sum of SI values of the proliferation assay and the sum of specific interferon-gamma spots (spots in the presence of antigen – spots in the medium control) against 5 individual HCV proteins (HCV-core, HCV-NS3, HCV-helicase, HCV-NS4, HCV-NS5a). In addition, the number of individual proteins tested positive at the respective time point is shown for each assay. Interferon gamma ELISPOT responses were also tested against a panel of synthetic peptides representing class I and class II T cell epitopes derived from conserved regions of HCV with a cumulative HLA coverage > 85%. These assays were performed in an independent second laboratory ("Pep-Screen ELISPOT"; Vienna lab). The number of peptides tested positive in this assay is also given

    Biochemical, virological and immunological course of acute hepatitis C in asymptomatic patients with spontaneous clearance: patients who developed anti-HCV antibodies

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Clearance of low levels of HCV viremia in the absence of a strong adaptive immune response"</p><p>http://www.virologyj.com/content/4/1/58</p><p>Virology Journal 2007;4():58-58.</p><p>Published online 11 Jun 2007</p><p>PMCID:PMC1914341.</p><p></p
    corecore