6 research outputs found

    The Impact of Borderline Quantiferon-TB Gold Plus Results for Latent Tuberculosis Screening under Routine Conditions in a Low-Endemicity Setting

    No full text
    Quantiferon-TB Gold Plus (QFT-Plus) is an interferon gamma release assay used to diagnose latent tuberculosis (LTB). A borderline range (0.20 to 0.99 IU/ml) around the cutoff (0.35 IU/ml) has been suggested for the earlier QFT version. Our aims were to evaluate the borderline range for QFT-Plus and the contribution of the new TB2 antigen tube. QFT-Plus results were collected from clinical laboratories in Sweden and linked to incident active TB within 3 to 24 months using the national TB registry. Among QFT-Plus results from 58,539 patients, 83% were negative (<0.20 IU/ml), 2.4% were borderline negative (0.20 to 0.34 IU/ml), 3.4% were borderline positive (0.35 to 0.99 IU/ml), 9.6% were positive (≥1.0 IU/ml), and 1.6% were indeterminate. Follow-up tests after initial borderline results were negative (<0.20 IU/ml) in 38.3%, without any cases of incident active TB within 2 years. Applying the 0.35-IU/ml cutoff, 1.5% of TB1 and TB2 results were discrepant, of which 52% were within the borderline range. A TB2 result of ≥0.35 IU/ml with a TB1 result of <0.20 IU/ml was found in 0.4% (231/58,539) of all included baseline QFT-Plus test results, including 1.8% (1/55) of incident TB cases. A borderline range for QFT-Plus is clinically useful as more than one-third of those with borderline results are convincingly negative upon retesting, without developing incident active TB. The TB2 tube contribution to LTB diagnosis appears limited

    Evaluation of 11 SARS-CoV-2 antibody tests by using samples from patients with defined IgG antibody titers

    No full text
    We evaluated the performance of 11 SARS-CoV-2 antibody tests using a reference set of heat-inactivated samples from 278 unexposed persons and 258 COVID-19 patients, some of whom contributed serial samples. The reference set included samples with a variation in SARS-CoV-2 IgG antibody titers, as determined by an in-house immunofluorescence assay (IFA). The five evaluated rapid diagnostic tests had a specificity of 99.0% and a sensitivity that ranged from 56.3 to 81.6% and decreased with low IFA IgG titers. The specificity was &gt; 99% for five out of six platform-based tests, and when assessed using samples collected ≥ 22 days after symptom onset, two assays had a sensitivity of &gt; 96%. These two assays also detected samples with low IFA titers more frequently than the other assays. In conclusion, the evaluated antibody tests showed a heterogeneity in their performances and only a few tests performed well with samples having low IFA IgG titers, an important aspect for diagnostics and epidemiological investigations

    Valorization of digestates from urban or centralized biogas plants: a critical review

    No full text

    Food waste valorization via anaerobic processes: a review

    No full text
    corecore