1,067 research outputs found

    Reactor power systems for manned earth orbital applications

    Get PDF
    Design requirements for reactor power system of manned earth orbital space statio

    Silver-Zinc Battery Separator Material Development

    Get PDF
    Ethylene/acrylic acid separators for silver zinc battery application

    Outstanding Educational Performance Awards: Highlighting Top Achieving Arkansas Schools, 2009

    Get PDF
    Since our founding in 2003, the mission of the Office for Education Policy has been to look at pressing issues through the lens of academic research and disseminate our findings to educators, policymakers, and other stakeholders around Arkansas. Every once in a while, however, we think it is okay to stray from issue analysis and simply share some good news! So, in this Arkansas Education Report (AER) we merely aim to highlight excellent performance and give our congratulations. To that end, we are happy to highlight the top performing schools around the state in an annual AER entitled the Outstanding Educational Performance Awards

    Characterisation of the Medipix3 detector for 60 and 80 keV electrons

    Get PDF
    In this paper we report quantitative measurements of the imaging performance for the current generation of hybrid pixel detector, Medipix3, used as a direct electron detector. We have measured the modulation transfer function and detective quantum efficiency at beam energies of 60 and 80 keV. In single pixel mode, energy threshold values can be chosen to maximize either the modulation transfer function or the detective quantum efficiency, obtaining values near to, or exceeding those for a theoretical detector with square pixels. The Medipix3 charge summing mode delivers simultaneous, high values of both modulation transfer function and detective quantum efficiency. We have also characterized the detector response to single electron events and describe an empirical model that predicts the detector modulation transfer function and detective quantum efficiency based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance recording a fully exposed electron diffraction pattern at 24-bit depth together with images in single pixel and charge summing modes. Our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous architecture for direct electron imaging

    Medipix3 Demonstration and understanding of near ideal detector performance for 60 & 80 keV electrons

    Full text link
    In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize either the MTF or DQE, obtaining values near to, or even exceeding, those for an ideal detector. We have demonstrated that the Medipix3 charge summing mode (CSM) can deliver simultaneous, near ideal values of both MTF and DQE. To understand direct detection performance further we have characterized the detector response to single electron events, building an empirical model which can predict detector MTF and DQE performance based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance, recording a fully exposed electron diffraction pattern at 24-bit depth and images in SPM and CSM modes. Taken together our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous and alternative architecture for direct electron imagin

    Silver-Zinc Battery Separator Material Development

    Get PDF
    Ethylene/methyl acrylate copolymer synthesis for silver-zinc battery separator

    One-Step Processing of Spinel Ferrites via the High-Energy Ball Milling of Binary Oxides

    Get PDF
    MnZn ferrites have been produced via the high-energy ball milling of binary oxide precursors. The milled ferrites have a nonequilibrium cation site distribution, with an unusually high population of Zn cations on the octahedral sites. The particle size distribution drops precipitously with milling time from 60±1 to ∼14±1 nm at 10 h, but increases to 18.5±1 nm after long durations (20–40 h) concurrent with the formation of nearly pure ferrite. A 1 h anneal at 673 K facilitates a redistribution of cations to their near equilibrium sites. This processing approach circumvents the need for deleterious high-temperature heat treatments that often lead to nonstoichiometries in the resulting ferrites

    A comparison of transgenic rodent mutation and in vivo comet assay responses for 91 chemicals.

    Get PDF
    A database of 91 chemicals with published data from both transgenic rodent mutation (TGR) and rodent comet assays has been compiled. The objective was to compare the sensitivity of the two assays for detecting genotoxicity. Critical aspects of study design and results were tabulated for each dataset. There were fewer datasets from rats than mice, particularly for the TGR assay, and therefore, results from both species were combined for further analysis. TGR and comet responses were compared in liver and bone marrow (the most commonly studied tissues), and in stomach and colon evaluated either separately or in combination with other GI tract segments. Overall positive, negative, or equivocal test results were assessed for each chemical across the tissues examined in the TGR and comet assays using two approaches: 1) overall calls based on weight of evidence (WoE) and expert judgement, and 2) curation of the data based on a priori acceptability criteria prior to deriving final tissue specific calls. Since the database contains a high prevalence of positive results, overall agreement between the assays was determined using statistics adjusted for prevalence (using AC1 and PABAK). These coefficients showed fair or moderate to good agreement for liver and the GI tract (predominantly stomach and colon data) using WoE, reduced agreement for stomach and colon evaluated separately using data curation, and poor or no agreement for bone marrow using both the WoE and data curation approaches. Confidence in these results is higher for liver than for the other tissues, for which there were less data. Our analysis finds that comet and TGR generally identify the same compounds (mainly potent mutagens) as genotoxic in liver, stomach and colon, but not in bone marrow. However, the current database content precluded drawing assay concordance conclusions for weak mutagens and non-DNA reactive chemicals

    Bioavailability, Antipsoriatic Efficacy and Tolerability of a New Light Cream with Mometasone Furoate 0.1%

    Get PDF
    Mometasone furoate, a potent glucocorticoid (class III) with a favorable benefit/risk ratio, has emerged as a standard medication for the treatment of inflammatory skin disorders. The purpose of the investigation presented here was to determine the noninferiority of a topical mometasone formulation, a light cream (O/W 60/40 emulsion) with mometasone furoate 0.1% (water content of 33%) versus marketed comparators. Using the vasoconstrictor assay, a strong blanching effect of the new cream (called Mometasone cream) comparable to that of a mometasone comparator, a fatty cream with mometasone furoate 0.1%, could be demonstrated. Thus, the topical bioavailability of the active ingredient mometasone furoate (0.1%) was regarded to be similar for Mometasone cream and the mometasone comparator. Using the psoriasis plaque test, a strong antipsoriatic effect comparable to that of the mometasone comparator was found for Mometasone cream after 12 days of occlusive treatment. A nearly identical reduction in the mean infiltrate thickness and similar mean AUC values were noted with both formulations confirmed by clinical assessment data. The noninferiority of Mometasone cream to its active comparator with re-spect to the AUC of change to baseline in infiltrate thickness was demonstrated. Both medications were well tolerated. Overall, Mometasone cream and the mometasone comparator showed similar efficacy and tolerability. Mometasone cream, in addition to its high potency and good tolerability, provides the properties of a light cream, which might make this new medication particularly suitable for application on acutely inflamed and sensitive skin. Copyright (C) 2012 S. Karger AG, Base
    • …
    corecore