12 research outputs found

    Retention properties with high-temperature resistance in (Bi,Pr)(Fe,Mn)O3 thin film capacitor

    Get PDF
    (Bi0.9Pr0.1)(Fe0.97Mn0.03)O3 (BPFM) thin film was deposited on Pt-coated Si(100) substrate by chemical solution deposition. Remnant polarization and coercive field in the BPFM film capacitor were 113 °C/cm2 and 630 kV/cm at the maximum electric field of 1000 kV/cm, respectively. Switching charge measured by a rectangular pulse measurement was 118 °C/cm2. Almost no polarization losses of BPFM film capacitor were observed even after retention time of 104 s at room temperature. Furthermore, the polarization loss at 450 °C was only 3.7% even after 104 s. These results indicate that BPFM film capacitor is suitable for non-volatile memory applications at high temperature. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

    Monitoring method for transgene expression in target tissue by blood sampling

    Get PDF
    In this study, we have developed a novel method to monitor transgene expression in tissues by blood sampling. We administered plasmid DNA (pDNA) encoding non-secretory form of firefly luciferase as a reporter gene and pDNA encoding secretable Gaussia princeps luciferase as a monitor gene simultaneously into mice. Good positive correlations were found between log-transgene expression of the reporter gene and the monitor gene in the treated muscle, between the monitor gene in the treated muscle and plasma, and consequently between the reporter gene in the treated muscle and the monitor gene in plasma after naked pDNA transfer into the muscle of mice. Such positive correlations were also found with gastric serosal surface instillation of naked pDNA, intravenous injection of lipoplex, and hydrodynamics-based injection of naked pDNA. We developed monitoring method of transgene expression in tissues by blood sampling, which was named ‘Therapeutic transgene monitoring (TTM)’, after ‘Therapeutic drug monitoring (TDM)’

    A pH-Adjustable Tissue Clearing Solution That Preserves Lipid Ultrastructures: Suitable Tissue Clearing Method for DDS Evaluation

    Get PDF
    Visualizing biological events and states to resolve biological questions is challenging. Tissue clearing permits three-dimensional multicolor imaging. Here, we describe a pH-adjustable tissue clearing solution, Seebest (SEE Biological Events and States in Tissues), which preserves lipid ultrastructures at an electron microscopy level. Adoption of polyethylenimine was required for a wide pH range adjustment of the tissue clearing solution.The combination of polyethylenimine and urea had a good tissue clearing ability for multiple tissues within several hours. Blood vessels stained with lipophilic carbocyanine dyes were deeply visible using the solution. Adjusting the pH of the solution was important to maximize the fluorescent intensity and suppress dye leakage during tissue clearing. The spatial distribution of doxorubicin and oxidative stress were observable using the solution. Moreover, spatial distribution of liposomes in the liver was visualized. Hence, the Seebest solution provides pH-adjustable, rapid, sufficient tissue clearing, while preserving lipid ultrastructures, which is suitable for drug delivery system evaluations

    Monitoring method for transgene expression in target tissue by blood sampling

    Get PDF
    In this study, we have developed a novel method to monitor transgene expression in tissues by blood sampling. We administered plasmid DNA (pDNA) encoding non-secretory form of firefly luciferase as a reporter gene and pDNA encoding secretable Gaussia princeps luciferase as a monitor gene simultaneously into mice. Good positive correlations were found between log-transgene expression of the reporter gene and the monitor gene in the treated muscle, between the monitor gene in the treated muscle and plasma, and consequently between the reporter gene in the treated muscle and the monitor gene in plasma after naked pDNA transfer into the muscle of mice. Such positive correlations were also found with gastric serosal surface instillation of naked pDNA, intravenous injection of lipoplex, and hydrodynamics-based injection of naked pDNA. We developed monitoring method of transgene expression in tissues by blood sampling, which was named ‘Therapeutic transgene monitoring (TTM)’, after ‘Therapeutic drug monitoring (TDM)’

    Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography

    No full text
    BACKGROUND: Multislice computed tomography (MSCT) is a promising noninvasive method of detecting coronary artery disease (CAD). However, most data have been obtained in selected series of patients. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64 MSCT) in daily practice, without any patient selection. METHODS AND RESULTS: Using 64-slice MSCT coronary angiography (CTA), 69 consecutive patients, 39 (57%) of whom had previously undergone stent implantation, were evaluated. The mean heart rate during scan was 72 beats/min, scan time 13.6 s and the amount of contrast media 72 mL. The mean time span between invasive coronary angiography (ICAG) and CTA was 6 days. Significant stenosis was defined as a diameter reduction of > 50%. Of 966 segments, 884 (92%) were assessable. Compared with ICAG, the sensitivity of CTA to diagnose significant stenosis was 90%, specificity 94%, positive predictive value (PPV) 89% and negative predictive value (NPV) 95%. With regard to 58 stented lesions, the sensitivity, specificity, PPV and NPV were 93%, 96%, 87% and 98%, respectively. On the patient-based analysis, the sensitivity, specificity, PPV and NPV of CTA to detect CAD were 98%, 86%, 98% and 86%, respectively. Eighty-two (8%) segments were not assessable because of irregular rhythm, calcification or tachycardia. CONCLUSION: Sixty-four-MSCT has a high accuracy for the detection of significant CAD in an unselected patient population and therefore can be considered as a valuable noninvasive technique

    Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography

    Get PDF
    OBJECTIVES: This study sought to evaluate the diagnostic accuracy of coronary binary in-stent restenosis (ISR) with angiography using 64-slice multislice computed tomography coronary angiography (CTCA) compared with invasive coronary angiography (ICA). BACKGROUND: A noninvasive detection of ISR would result in an easier and safer way to conduct patient follow-up. METHODS: We performed CTCA in 81 patients after stent implantation, and 125 stented lesions were scanned. Two sets of images were reconstructed with different types of convolution kernels. On CTCA, neointimal proliferation was visually evaluated according to luminal contrast attenuation inside the stent. Lesions were graded as follows: grade 1, none or slight neointimal proliferation; grade 2, neointimal proliferation with no significant stenosis ( or =50%); and grade 4, neointimal proliferation with severe stenosis (> or =75%). Grades 3 and 4 were considered binary ISR. The diagnostic accuracy of CTCA compared with ICA was evaluated. RESULTS: By ICA, 24 ISRs were diagnosed. Sensitivity, specificity, positive predictive value, and negative predictive value were 92%, 81%, 54%, and 98% for the overall population, whereas values were 91%, 93%, 77%, and 98% when excluding unassessable segments (15 segments, 12%). For assessable segments, CTCA correctly diagnosed 20 of the 22 ISRs detected by ICA. Six lesions without ISR were overestimated as ISR by CTCA. As the grade of neointimal proliferation by CTCA increases, the median value of percent diameter stenosis increased linearly. CONCLUSIONS: Binary ISR can be excluded with high probability by CTCA, with a moderate rate of false-positive results
    corecore